So I can get ASCOM 6p1 and SkyX to talk to each other via the ComSoft PC-TCS driver. It tracks, slews, parks. But there's a couple problems I'm having since...
27966
Bob Denny
dc3dreamer
Aug 1, 2012 3:41 pm
Hi -- This is a bit difficult to diagnose because thers is no evidence to help pinpoint where this stuff is happening. I suggested on the phone the other day ...
27967
Adam
adamrosas1972
Aug 2, 2012 10:48 pm
well so far my driver has not done anything unexpected, passes conform points the telescope and pulse guides. it is very unfinished, but thought that it was...
27968
Chris
scope_sapiens
Aug 3, 2012 9:03 pm
That looks pretty good Adam, I'd do things slightly differently but it's mostly a difference in style. I'd use the ASCOM serial classes rather than rolling my...
27969
Adam
adamrosas1972
Aug 5, 2012 9:13 pm
Thanks Chris, The purpose of the serial wrapper was so I could use my dodgy Belkin serial port to USB adapters, I purchased a Prolific serial to USB adapter...
27970
skyhawkdriver727
skyhawkdrive...
Aug 8, 2012 6:58 am
Hi, I'm using a Meade LX200 ACF and have had no trouble using ASCOM to drive the scope using Starke Labs PHD software or PemPro. In addition, I was able to...
27971
Graham Edridge
theerker
Aug 8, 2012 7:11 am
Hi, Dave. Mine stopped working about 6 months ago with a similar combination of kit & software etc and I posted a similar cry for help. A helpful chap called...
27972
autostaretx
Aug 8, 2012 3:47 pm
Obvious questions: (a) what did you do (install/remove/change) just BEFORE the first symptom? (did you do an XP System Restore for some reason?) (b) have you...
27973
ciapes
Aug 9, 2012 5:20 pm
Dear all, let me introduce myself. I am an italian astrophile who is trying to use a brand new Dobson SW Goto 12 as a photographic platform. I am using an...
27974
Adam
adamrosas1972
Aug 9, 2012 6:36 pm
pulse guiding is not supported in Alt/Azm mode. I am curious what the technical reason for this, is it just a bad idea because the object is constantly moving...
27975
tandum57
Aug 9, 2012 6:39 pm
I had to replace the mobo in my dome PC and reinstall windoze. I used a new hard drive to do this and would like to pull the POTH data from the old hard drive...
27976
tandum57
Aug 9, 2012 6:40 pm
go to http://memtest86.com/, get the free ISO, burn to CD, boot from that CD and run overnight. The MS memtest is of poor quality. robin...
27977
Chris
scope_sapiens
Aug 9, 2012 6:57 pm
I looked at this when I was implementing PulseGuide for the Celestron scopes. Getting the guide directions and rate correct in the Ra and Dec directions is not...
27978
skyhawkdriver727
skyhawkdrive...
Aug 9, 2012 8:01 pm
Dick a) Nothing. no changes to computer or scope. b) The computer rarely uses the internet. I have anti-virus off and firewall off unless I go on-line. After...
27979
ciapes
Aug 9, 2012 9:19 pm
I have the rotator (optec pyxis with new alt az derotation server software) and it works perfectly! But I cannot drive. The driver that I have to use is the...
27980
Chris Rowland
scope_sapiens
Aug 9, 2012 9:54 pm
... I'm not planning to change the Celestron driver. My feeling is that the Celestron driver is complex enough without having to support other manufacturer39;s...
27981
autostaretx
Aug 10, 2012 1:20 am
So now we move on to how doesn't it work? Can the Chooser connect to the driver (i.e. you can fetch up the driver's Properties/Setup screen?) Can the driver...
27982
Tim Long
t_p_long
Aug 10, 2012 1:57 am
All good sound advice Dick, well done. Just to expand one point slightly, if you need a replacement for HyperTerminal on later versions of Windows, you can try...
27983
Adam
adamrosas1972
Aug 10, 2012 3:47 am
You just saved me countless hours trying to get that to work. I fought my battles with that tracking delay during my first few attempts at pulse guiding. I...
27984
James
vikel
Aug 10, 2012 6:31 am
I have a Meade Lxd mount with a #497 handbox. The Ascom web site says to use classic Meade for the #497 handbox. I downloaded the right Ascom driver but when...
27985
dmwmpd
Aug 10, 2012 3:20 pm
Have you looked at the SiTech controller system? It requires servos, not steppers, but can handle Alt-Az just fine. It's an ASCOM 6 hub so it's easy to...
27986
skyhawkdriver727
skyhawkdrive...
Aug 11, 2012 6:17 am
I appreciate your help but you've lost me. The message I get is: PROBLEM LOADING ASCOM DRIVER. Can the driver attach to the COM port? NO Is it able to Connect...
27987
ciapes
Aug 11, 2012 6:18 am
Many thanks for all your advices and suggestions. Interesting the new Sitech controller. But before going on that I would like to try the adventure to build...
27988
Chris Rowland
scope_sapiens
Aug 11, 2012 7:07 am
... You're talking of an inexpensive mount with an expensive field derotator ($695). I think the amateur astrophotography world has found that they get more...
27989
Adam
adamrosas1972
Aug 11, 2012 7:55 pm
http://code.google.com/p/ascom-nexstar-telescope/source/browse/NexStar/Common.cs line 2722 change to return true, that should allow PHD Guiding to try pulse...
27990
Anthony
adavoli2001
Aug 11, 2012 9:04 pm
I could use a little help installing the correct ASCOM drivers for my system. I apologize if this seems straight forward to most of you but I have been...
27991
autostaretx
Aug 11, 2012 11:42 pm
... (a) he's running Windows XP (b) he gets the error message when clicking the Properties button in the Chooser for the selected driver (Classic and Autostar...
27992
Rick Burke
astromanrick
Aug 12, 2012 12:19 am
Is the driver installed and registered correctly? I would try to install the driver again. ... From: ASCOM-Talk@yahoogroups.com...
27993
autostaretx
Aug 12, 2012 12:38 am
He had reinstalled the driver... but he just PM'd me that he just reinstalled both the platform and the driver... and it now works. Question: during the...
27994
James
vikel
Aug 12, 2012 6:52 am
I posted this a few days ago but no one has responded so I am doing it again. I also have a picture of my screen with Alignmast, the chooser box and when I...