Does anyone have an idea how one can detect CAN Overrun with NECV850 processor ? There doesn't seem to be an indication from Hardware (register) over which...
Balakrishnan Muthukri...
balakrishm@...
Mar 2, 2007 5:34 pm
6017
Hi all, i have several doubts about the SYNC message of the CANopen specification. I have a CAN bus with two ADC CANopen devices, to acquire several analog...
juanp_garciao
jportiz@...
Mar 4, 2007 1:06 am
6018
Hi, ... the modules will only answer in "Operational Mode" so you have to start the nodes by sending a NMT-Command "Start Node" or "Start All Nodes". But you...
Torsten Krahl
krahl@...
Mar 5, 2007 10:15 am
6019
Hello, I am having trouble configuring a Thermocouple/mV sensor device from Squarell Technology, and was hoping some others here have experience with this...
Mike James
james@...
Mar 13, 2007 10:42 pm
6020
Hi, I'm monitoring the TEC and REC register of the TMS470R1B512 Microcontroler, In order to view the behavior of the registers, I take off the bus cable My...
Marcelo
msrmailxxx@...
Mar 15, 2007 10:09 pm
6021
Hi Marcello, ... No it shouldn't. It will continue to transmit because it's the only one on the bus since you disconnected the cable. ... What I did years ago...
John Dammeyer
johnd@...
Mar 15, 2007 11:04 pm
6022
Hi, I am currently performing a software worstcase analysis on a certain module with CAN. Any idea on how will I do worstcase analysis on the CAN driver? ...
Chan, Jig Anthony
JChan01@...
Mar 16, 2007 6:55 am
6023
You should be able to operate at 90% to 95% load, with load for high priority messages. Then keep changing the mix to evaluate performance. Regards Uday...
Uday_Gokhale
Uday_Gokhale@...
Mar 16, 2007 1:20 pm
6024
... I think the CAN specification lays it out: "When a TRANSMITTER sends an ERROR FLAG the TRANSMIT ERROR COUNT is increased by 8. Exception 1: If the...
Gerhard Uttenthaler
uttenthaler@...
Mar 16, 2007 2:49 pm
6025
Hi Marcello, John, It should be simpler than that: Just add some extra nodes on the bus and set them on different bitrates. One will not be enough probably,...
Kees Zagers
kees@...
Mar 16, 2007 3:12 pm
6026
Hello Marcelo, 1. ACK error: The TEC counter increases until 128 and stays there. Now it keeps trying to send its message until eternity. 2. Any other error:...
Kees Zagers
kees@...
Mar 16, 2007 4:14 pm
6027
It means that the controlle will never reach the Bus-off State with only two nodes in the bus ? It must have a manner of reach 255 in the TEC register with...
Marcelo
msrmailxxx@...
Mar 16, 2007 4:39 pm
6028
My test method is like that : 1) I take off the bus cable, when the controller transmits the first message, and nobody answers with ACK, it increases 1 TEC. It...
Marcelo
msrmailxxx@...
Mar 16, 2007 4:48 pm
6029
What if you try the following: 1. No receiving module. TEC register goes up to 128 because of no ACK. 2. Plug on the receiving module on a wrong bitrate; now...
Kees Zagers
kees@...
Mar 16, 2007 5:33 pm
6030
The main question is : Why can't I put a node in the Bus-off state with only two nodes in the bus ? Why my TEC counter reaches 128 and don't increases anymore...
Marcelo
msrmailxxx@...
Mar 16, 2007 5:39 pm
6031
Hi Marcelo, Your previous question was why one node wouldn't reach bus off. The simple answer is because the specification says that it's not supposed to go...
John Dammeyer
johnd@...
Mar 16, 2007 8:15 pm
6032
Hi Kees, Yes. A much lower speed node will also cause long error flags which will dominate the bus forcing each node to back off and retry and eventually they...
John Dammeyer
johnd@...
Mar 16, 2007 8:19 pm
6033
Hi, I would like to thank you all very much, i'm really gratefull...with two other nodes in the bus at a lower BaudRate, the TEC counter goes to 255 and the...
Marcelo
msrmailxxx@...
Mar 16, 2007 9:50 pm
6034
Hi Marcelo, ... That's correct. ... That's correct. Things are working the way they are supposed to. ... That's an inconclusive method of testing since the...
John Dammeyer
johnd@...
Mar 16, 2007 10:13 pm
6035
a follow up to my own question - I found this erratum - has anyone seen this work on a TouCAN module - especially on a PowerPC 565? ... CDR_AR_1045 Customer...
Corey, Richard
Richard.Corey@...
Mar 16, 2007 10:50 pm
6036
Is anyone familiar with the "TouCAN" implementation by Freescale? I think it is very similar to "FlexCAN". Re-reading the User Manual section on TouCAN did...
Corey, Richard
Richard.Corey@...
Mar 16, 2007 11:43 pm
6037
Greetings; I am trying to monitor my CAN bus activity using the Gridconnect/Acacetus CAN-USB Light convertor, and I have hit a snag. Whenever a message comes...
Sam Webb
divisionbyzorro@...
Mar 25, 2007 8:28 pm
6038
Greetings; I am trying to monitor my CAN bus activity using the Gridconnect/Acacetus CAN-USB Light convertor, and I have hit a snag. Whenever a message comes...
Sam Webb
divisionbyzorro@...
Mar 25, 2007 8:29 pm
6039
Hello First a background: I need to say up front that I don't have any of the standards yet, and I'm doing my best to gain access to them without breaking my...
Luke and Kim Plaizier
lukeyson@...
Mar 27, 2007 11:29 am
6040
Hello, Is it possible to modify/alter the CRC value just before the CAN frame is transmitted on to the bus? Regards, Arun...
Arun Gopalakrishnan (...
Arun.Gopalakrishnan@...
Mar 27, 2007 1:07 pm
6041
... Yes (SCNR). Oliver -- Oliver Betz, Muenchen -- Archives and useful links: http://groups.yahoo.com/group/CANbus Subscribe and unsubscribe at...
Oliver Betz
list_ob@...
Mar 27, 2007 2:19 pm
6042
Hi, I'm working with the TMS470R1B512 Microcontroller, and there is a situation in which I need to reset the TEC and REC registers. These register are Read...
Marcelo Rodrigues
msrmailxxx@...
Mar 29, 2007 9:09 am
6043
Hi All On the MPC565 PowerPC, TouCAN receives every packet that it sends. Does anyone know a way to suppress that with some configuration setting? I didn't...
Corey, Richard
Richard.Corey@...
Apr 4, 2007 6:46 pm
6044
... That is what can4linux is doing as well. if the received message has the same Id as the message last sent, throw it away. You can look at the source code. ...
Heinz-Jürgen Oertel
oe@...
Apr 4, 2007 8:43 pm
6045
... Rick Corey - Crane Aerospace Lynnwood - 425-743-8469 Mobile - 908-887-0722 ... From: Heinz-Jürgen Oertel [mailto:oe@...] Sent:...