Hi All On the MPC565 PowerPC, TouCAN receives every packet that it sends. Does anyone know a way to suppress that with some configuration setting? I didn't...
Corey, Richard
Richard.Corey@...
Apr 4, 2007 6:46 pm
6044
... That is what can4linux is doing as well. if the received message has the same Id as the message last sent, throw it away. You can look at the source code. ...
Heinz-Jürgen Oertel
oe@...
Apr 4, 2007 8:43 pm
6045
... Rick Corey - Crane Aerospace Lynnwood - 425-743-8469 Mobile - 908-887-0722 ... From: Heinz-Jürgen Oertel [mailto:oe@...] Sent:...
Corey, Richard
Richard.Corey@...
Apr 4, 2007 9:37 pm
6046
Hi, we have also run into the same problem when we used a Freescale CPU with FlexCAN controller. In the end we found this controller not supporting all of our...
Bertil Bäck
bertil@...
Apr 5, 2007 7:27 am
6047
Hi all, I'm trying to use two MCP2515 (with MCP2551 transceivers) to send data between two PIC16F873A chips. At the moment I am just trying to get one node to...
Sam Jelfs
sam.jelfs@...
Apr 10, 2007 10:01 pm
6048
Hi all, what happened to the "Device Profile for Human Machine Interfaces" specification? I don't find it on the CiA specifications list. Regards, Johannes...
Johannes Quercia
jquercia@...
Apr 11, 2007 3:45 pm
6049
Hello Johannes, this CiA403 is obsolete. Meanwhile years ago there were some activities for standardisation of HMIs in CANopen. Then there was a try to use...
Klüser, Jürgen
Juergen.Klueser@...
Apr 12, 2007 7:50 am
6050
Hi all, I have a sensor with the CAN bit timing as follows Sync segment = 200nsec; Time segment 1 = 1200nsec; Time segment 2 = 600nsec.; sync jump width =...
Ram
rams@...
Apr 12, 2007 2:18 pm
6051
Hi all, I have a sensor with the CAN bit timing as follows Sync segment = 200nsec; Time segment 1 = 1200nsec; Time segment 2 = 600nsec.; sync jump width =...
Ram
rams@...
Apr 12, 2007 3:28 pm
6052
The first thing you need to know is, there is no such thing as "std values for standard 11bit CAN"; the key point is what baud rate they are using to ...
Allen Pothoof
apothoof@...
Apr 12, 2007 4:05 pm
6053
Hi, Somebody has some document or information about the Scania Motor Coordinator System (COO System). I have already searched by Google and at the Scania Web...
Marcelo Rodrigues
msrmailxxx@...
Apr 12, 2007 4:27 pm
6054
Hi Al, thanks for your reply. The sensors use 500kbps to communicate. ... -- Archives and useful links: http://groups.yahoo.com/group/CANbus Subscribe and...
Ram
rams@...
Apr 12, 2007 6:14 pm
6055
I think you're right in that the numbers don't quite work out. If I plug an oscillator frequency of 16Mhz and a baud rate of 500kBPS into the calculator, it...
Allen Pothoof
apothoof@...
Apr 12, 2007 9:43 pm
6056
Hi Al, Thanks for your reply. No i getting a clear picture of whatz going on. Can you please tell me how to calculate the TQ in my case (16/8) and the sample...
Ram
rams@...
Apr 12, 2007 10:30 pm
6057
You have two possibilities. Contact Mike Schofield at mschofield@... for his CANTIME Software. Very useful tool. Or ...
John Dammeyer
johnd@...
Apr 13, 2007 12:01 am
6058
Just my thougths. With a sample point at 62.5% it works on the test-bench. But what if longer cables are used? A DeviceNet rule is that 500kbps has a max trunk...
rene.heijma@...
Apr 13, 2007 7:39 am
6059
Hi, Mike Scofield's CANTIME suggests that with a 16MHz clock and a 62% sample point for 500kbps you could get as short a distance as 42 metres but no more than...
John Dammeyer
johnd@...
Apr 13, 2007 7:14 pm
6060
Did some more playing around with the bit time calculator this morning. There is a bit-timing that uses 15 TQ that has "only" a 6.667% error. Preferred timings...
Allen Pothoof
apothoof@...
Apr 16, 2007 4:46 pm
6061
Hi Al, I really appreciate ur help..thankyou very much. just simulated the test in the field with the big trunk harness and i ocassionally get few bus ...
Ram
rams@...
Apr 16, 2007 6:36 pm
6062
If you see error-frames you are at the edge of what is possible. Just one more influencing factor and your communication is gone. Better is to have no...
rene.heijma@...
Apr 17, 2007 10:18 am
6063
Hi, I'm working with a J1939 stack and need to decode the SPN (Suspect Parameter Number). The SPN could be decodified into four versions, the bit CM...
Marcelo Rodrigues
msrmailxxx@...
Apr 17, 2007 10:19 pm
6064
Hi Al, How can i use CANeo (CAPL) to put it in LinSlave ? an exemple (like getting start) will be very nice ;) thanks ...
m m
museagle@...
Apr 18, 2007 11:14 am
6065
The answer is simple, but probably not what you want to hear. The original specification was not clear, and resulted in at least three different...
Jim DeVore
jim@...
Apr 18, 2007 4:06 pm
6066
LIN operations differ from version 5.2 to version 6.0 of Vector CANoe tool. But, within the application directory, you have a few examples softwares available....
MARC Erwan
erwan.marc@...
Apr 19, 2007 4:33 pm
6067
Hello friends, The following is less than technical but.... Can anyone please point me to where I can purchase CAN terminator similar to the CANterm of Vector....
Moshe Barazani
mbarazani@...
Apr 23, 2007 10:36 am
6068
... Moshe, I have seen the same termination at another CAN solution provider. Unfortunately, it was not port. But I can't remember which company. Regards Heinz...
Heinz-Juergen Oertel
oe@...
Apr 23, 2007 11:55 am
6069
Please check this website. http://www.gridconnect.com/gc-can-term.html cheers Viks...
Vikram Rajput
vsrajput@...
Apr 23, 2007 4:04 pm
6070
Hello, I got over 1600 hits on Google for "CAN terminator". Cheers, Steve C. ________________________________ From: canlist-owner@......
Corrigan, Steve
s-corrigan1@...
Apr 23, 2007 5:55 pm
6071
... Steve, That exactly is the problem for him. He is not looking what such a beast is good for, butt for a real product. Vector sold one build in in a Dsub-9...
Heinz-Juergen Oertel
oe@...
Apr 23, 2007 7:09 pm
6072
Hello Moshe, i've got some from Phoenix Contact. M12 A-cod 5pol Type: SAC-5P-M12MS CAN TR. Nr: 1507816. Regards Jan ... From: "Moshe Barazani"...