My original post seemed to be thrashed pretty badly, let me revise: [quote] but really its almost as simple as Open, Close, Send, Receive [/quote] Revised: ...
stunbmun
stunbmun@...
Dec 1, 2008 8:12 pm
6843
Hi Team, I am using twisted pair wires as can bus. Up to baud rate of 125Kbps the transmission and reception are working smoothly. If I am going to higher rate...
Joy.George@...
Dec 2, 2008 4:42 am
6844
Hi Team, I am using TMS320F2812 DSP processor and To implement CAN communication between two processors (TMS320F2812) I am using PCA820C250 transceiver and...
Kasunaidu.Vechalapu@...
Dec 2, 2008 5:58 am
6845
Hi, Could you tell us the length of your bus? It must be Changing the sample point to greater than 83% is required to get 30m distance. John Dammeyer ...
John Dammeyer
johnd@...
Dec 2, 2008 7:00 am
6846
Hi, We are in the initial state of implementing CAN protocol. Presently we are using 2 meters length of twisted pair CAN bus between two nodes. And we are...
Kasunaidu.Vechalapu@...
Dec 2, 2008 7:38 am
6847
Are you able to capture a scope photograph of a bus message? Set your software to send a single short 0 data length message with an 11 bit ID. Set your...
John Dammeyer
johnd@...
Dec 2, 2008 7:51 am
6848
... Very often this is the only problem. But of course, with 1Mbit/s also a correct connection of the transceiver th the media is importand. We had cases were...
Heinz-Juergen Oertel
oe@...
Dec 2, 2008 11:17 am
6849
Hi, we also use TMS30F2812 DSP, we are using with BR 500kbps, but we have also used successfully with 1 Mbps. IMO you may check some things may be the cause of...
Osmar Yang
oy@...
Dec 2, 2008 11:19 am
6850
Hi, We have grounded the "slope control" pin (pin 8, Rs). As per the data sheet grounding of pin 8 gives "high speed mode". Thanks&Regards, V.Kasunaidu Emerson...
Kasunaidu.Vechalapu@...
Dec 2, 2008 11:22 am
6851
Hi Osmar, - Our terminating impedance is 124 Ohm (two 62 Ohm split resistors are used; 2.2nF capacitance is used between midpoint of split resistor...
Kasunaidu.Vechalapu@...
Dec 2, 2008 12:13 pm
6852
Hi, you´re right, the clock is 15 MHz (I was thinking about our other nodes using PIC, which use an external oscillator with 16 MHz). The only difference I...
Osmar Yang
oy@...
Dec 2, 2008 5:48 pm
6853
Hi, We are using Optocoupler (6N135) between CAN transceiver and TMS320F2812 DSP processor. Same setup is used in both the nodes. We are able to transmit upto...
Kasunaidu.Vechalapu@...
Dec 3, 2008 12:23 pm
6854
Hi, Go to ti.com and order free samples of the ISO7221M. This will solve that problem. Steve ________________________________ From:...
Corrigan, Steve
s-corrigan1@...
Dec 3, 2008 4:48 pm
6855
Hi, The 0.6uS delay is your clue. Let's walk through the theory assuming 0 propagation time through the wire but with 50nS through the CAN controller logic...
John Dammeyer
johnd@...
Dec 3, 2008 7:32 pm
6856
Hi there - I want to run a single cable with as few conductors as possible that carries CAN and power that will be subjected to all sorts of tortures. It needs...
Michael J. Noone
mnoone@...
Dec 4, 2008 11:42 pm
6857
I did a similar thing once with an RS485-based bus for the fire industry. The "single cable" part is the problem here, though. In the fire industry, the...
Geoff Field
geoff_field2003@...
Dec 5, 2008 11:36 pm
6858
Perhaps you ought to look at FlexRay if your need is so critical. Some (many?) CAN controlers are not able to work under all fault conditions as described in...
Robert Boys
RBoys@...
Dec 7, 2008 7:23 am
6859
Hi, What about using a star topology? You can check the work on CANcentrate: http://dmi.uib.es/~mbarranco/srvlsestars/description.htm Just a thought as well. ...
Guillermo Rodrígue...
guillermo.rodriguez-n...
Dec 8, 2008 12:26 am
6860
Hello, Or how about a CAN-switch? Please take a look at: http://www.tke.fi/can_hardware_6_1.htm BR, -H ... Heikki Saha Sandvik Mining and Construction...
heikki.saha@...
Dec 8, 2008 6:36 am
6861
Hi everybody, I'm reading my way through DSP402 V3 and don't get how to convert from user velocity values to internal speed values and vica versa. In former...
Zeisluft Thomas
Thomas.Zeisluft@...
Dec 10, 2008 11:48 am
6862
This sounds reasonable. ... - Jon http://www.cancapture.com CANCapture: Advanced CAN and J1939 Analysis Software -- View this message in context:...
stunbmun
stunbmun@...
Dec 10, 2008 9:31 pm
6863
Hi, did anybody ever hear about long CAN messages? We ran across a J1939 Error answer message containing 18 data bytes. regards Peter...
Peter Lauer
plauer@...
Dec 12, 2008 3:43 am
6864
Hi Peter, J1939 contains the Transport Protocol that enables messages to be longer than standard 8 data bytes. When sent on the bus the long message is...
Magnus Wikman/TKE
magnus.wikman@...
Dec 12, 2008 7:15 am
6865
Peter, The J1939 spec defines a way to split long messages in multiple CAN frames using either the BAM (broadcast) or the CTS/RTS (point-to-point) technique. ...
Bram Kerkhof
canbus@...
Dec 12, 2008 7:24 am
6866
Hi Peter, J1939 uses transport protocols for transmission of data with more than 8 byte. From the application point of view it is a "long message", but on the...
Klüser, Jürgen
Juergen.Klueser@...
Dec 12, 2008 7:49 am
6867
Hi, I¡¯m programming A test program with Panel Editor but cannot find any idea of using RS232 Serial data. Does anybody know about this problem or something...
dylee@...
Dec 12, 2008 11:21 am
6868
Hello, What about a star CAN repeater with up to 24ports (3 repeaters within a cascade chain, each having 8 ports) ...
Sebastian Haas
canlist@...
Dec 15, 2008 5:12 pm
6869
... De: notify@yahoogroups.com [mailto:notify@yahoogroups.com] En nombre de fexdelu Enviado el: Viernes, 12 de Diciembre de 2008 12:03 p.m. Para: JXLL Asunto:...
JXLL
jxll29@...
Dec 15, 2008 5:37 pm
6870
Using a GPS equipment Virloc 4E, I have managed to extract J1939 information from a International 7600 Truck, which uses a Cummins Engine. 26-11-2008 16:27:56...
BetoGPS
alobos@...
Dec 16, 2008 1:15 pm
6871
Hi, don't know much about International trucks but it seems like a problem that could be solved if the truck had a FMS port. ...