I second that. You can turn off the opening address book thing already, but Compile All would be great. ... [Non-text portions of this message have been...
Here's another one... don't blank the Program Compilation log every time I paste something. I like to use the log as a sort of "todo" list to chase down the...
I am adding a couple of high capacity cresnet devices. Each require their own 75 watt power supply. I have 2 and will be adding 2 more wired touch panels. I...
Hi Chip, The official line is "Use Crestron power supplies or else...." However, there are a few things to keep in mind if you don't always use Crestron...
If I'm reading your reply to my question correctly, then when using a Crestron supply, only the 24+ is interrupted and the supply picks up it's own 24+ on...
Hi Eugene Did you ever come right with using a uPnP, or DLNA source for a crestron system, say a AES or something. Please share any info regarding this issue. ...
... That's a very good point - 42 AMPs would require a #8 or maybe #6 wire to keep it safe. A short might well destroy the #18 cable in Cresnet. This is why...
If you locally power it, you will have power on it. I've made a system in the pas with qmrmcrx slave to a master processor and they are powered locally. ...
Hi to all, I have received a compiled Touch Panel file (.vtz) The instruction was for me to load it, I am just new with Crestron and have'nt experienced yet...
Nothing stopping anyone from putting the Cresnet legs through a power distribution block with three-amp fuses.... Altronix PD8 or some such. Size and fuse...
Have you ever seen a fried cresnet wire due to an innapropriate power supply. It's not funny. Raphaël Thiffault, CTS Programmeur Intégrations Duocom Canada...
Not sure I'm following the question on "interruption". Power supplies like the CNPWS75 have two connections that completely "pass through" to each other, with...
Glenn, you need to get a copy of a utility called "Toolbox" from Crestron's website. You can use the "Info" tool to connect to your touch panel over Ethernet...
I have a ps3ir-x1 from schmartz. Its just a usb stick that plugs into the playstation usb port. So far nothing works. Does anyone know if this one works with...
In the past I have succesfully integrated a G3-48 and a G3-128 using the module from the crestron EU site. I say succesful in that I was able to (eventually)...
There was a 50W DIN rail PSU available in Europe that had 4-way connectors that did not internally connect the +24V. it has now been replaced with a newer...
Now I'm really confused. I thought the 75 did isolate it's output from the cresnet. If you had a large system that required ten 75's that were not isolated,...
No, they're just paralleled -- makes for a much more versatile product. Proper system design, though, dictates that only one power supply should be powering...
I have created a module suite that are basically sets of GUI Interface Modules, Room modules, CHV-TSTAT, and Homeworks currently. Sort of like the Crestron...
ive been working on this for two days tryed crestron demo program and still no luck.i keep getting a unsupported project file error on my itouch someone please...
Have any of you experienced this? I have an RX-V3800 that has been working fine for the last year and a half, and today after uploading a new simpl file, it...
the file is really small only have two button volume up and volume down. i tryed crestron demo still know luck say the same error on the itouch. ihave windows...
I have 2 questions. The first is I was wondering if there is a way in Simpl+ to send and recieve commands to the console, right now I use the external console...
did web project in control system is password protected? try to remove the password. Regards, ~Yohan Ismu Hardinugroho~ . [Non-text portions of this message...
had the same problem, when you go to load the project through vtpro, go to set user password and then disable it. although you never set one you still have to...