1702
Hi, Can anyone tell me how to get a link into the schematic so that the PDF from DxPDF will have a working link? Right now all my links work wfrom within...
Jonathan Hurst
jackolantern26
Offline Send Email
May 1, 2003
7:31 am
1703
Are you using a UNC path, absolute path, or http path? Make sure you have defined the URL valued attribute in the DxPDF gui on the Options tab. If you are...
Fernsebner, Dan
dfernseb
Offline Send Email
May 1, 2003
11:43 am
1704
Oh, I was unaware of that. I'll definitely keep that in mind when we upgrade then. Thanks. Kevin ... From: Gary Lameris [mailto:glameris@...] Sent:...
McCracken, Kevin
ksm75cn98ha
Offline Send Email
May 1, 2003
2:03 pm
1705
I want to use both. The idea is that the local guys here can look at the schematic and grab the local datasheets if they want to check anything in the parts......
Jonathan Hurst
jackolantern26
Offline Send Email
May 1, 2003
2:07 pm
1706
No, Viewdraw, DxDB, and DxPDF do not support UNC paths, so a way around this is to use URI paths. The attribute can be anything you want. The value would...
Fernsebner, Dan
dfernseb
Offline Send Email
May 1, 2003
2:28 pm
1707
I tried that but it isn't working. All of the links are working in viewdraw.. none in DxPDF I will archive it at send it to you . THanks. ... Van: Fernsebner,...
Jonathan Hurst
jackolantern26
Offline Send Email
May 1, 2003
2:40 pm
1708
Dan, I would love to get this working in DxPDF, but alas, I have not been able to. I have placed an unattached attribute to the schematic as follows ...
Austin Franklin
austinfranklin
Offline Send Email
May 1, 2003
4:16 pm
1709
Jonathan, I apologize for the delay of my response - it's been a busy day. To get the URLs to work in DxPDF do the following: 1) Depending upon where the...
Fernsebner, Dan
dfernseb
Offline Send Email
May 1, 2003
7:46 pm
1710
Correction line three should read: 3) Make sure the Attribute values are as follows: DATASHEET=C:/TEMP/EMAIL.TXT Note the forward slashes - back slashes are...
Fernsebner, Dan
dfernseb
Offline Send Email
May 1, 2003
8:15 pm
1711
I think I get what you mean... are you telling me that the pop-up menu from the DxPDF will never have a working link on it? but if I leave the links dragging...
Jonathan Hurst
jackolantern26
Offline Send Email
May 2, 2003
6:40 am
1712
Hey Dan, I am on central European time so don't worry about what time it is there ;) so long as you get back to us we'll all be happy campers. ... Van:...
Jonathan Hurst
jackolantern26
Offline Send Email
May 2, 2003
6:42 am
1713
Ok, I got it working, so it is either-or but not both. I cannot have all the extra attribute information -and- have a link attached to the part. I can have one...
Jonathan Hurst
jackolantern26
Offline Send Email
May 2, 2003
6:51 am
1714
Jonathan, You can have both the component pop ups as well as the hyperlinks as long as they don't over lap. The problem is when the two links overlap the...
Fernsebner, Dan
dfernseb
Offline Send Email
May 2, 2003
11:32 am
1715
So... I need to leave them lying around in my schematic? Maybe I can cram them all into a little table in the corner... any idea how i could make it work so...
Jonathan Hurst
jackolantern26
Offline Send Email
May 2, 2003
1:47 pm
1716
Hey Dan, Is it possible to controll teh length of the thing? I have left the links dragging around in the schematic now.. and they work but the outline goes...
Jonathan Hurst
jackolantern26
Offline Send Email
May 2, 2003
1:50 pm
1717
Use the URI methodology that I previously discussed. Example: DATASHEET=C:/temp/email.txt (By the way this works as well if you want to use back slashes...
Fernsebner, Dan
dfernseb
Offline Send Email
May 2, 2003
2:32 pm
1718
Unfortunately not - there is currently an enhancement to have the length of the URL link be configurable and/or conform to the size of the attribute if only...
Fernsebner, Dan
dfernseb
Offline Send Email
May 2, 2003
2:33 pm
1719
If you want to embed the datasheets pdfs into the pdf for a (BIG) single file schmatic and datasheet file... Create the DxPDF with embedded datasheet links (I...
Gary Lameris
glameris
Offline Send Email
May 2, 2003
7:39 pm
1720
Here is how my DxPDF works I have an attribute called DATASHEET, it is invisible and it has the hyperlink to the file. I usually attach to our server, but for...
Gary Lameris
glameris
Offline Send Email
May 2, 2003
8:34 pm
1721
Are they then linked in the document too? how can I get it to capture them from my netware drive w:// ? ... Van: Gary Lameris [mailto:glameris@...] ...
Jonathan Hurst
jackolantern26
Offline Send Email
May 5, 2003
10:13 am
1722
Am I doing it wrong? When I hit Ctrl-Alt-G I get the project settings, but only if the project navigator window is open? Does this sound like the same behavior...
Jonathan Hurst
jackolantern26
Offline Send Email
May 5, 2003
12:19 pm
1723
I assume this has the same cause as why ctrl-C and ctrl-V don't work anymore, whenever one of the plugins is switched on or off (depending on their initial...
vbee1970
Offline Send Email
May 5, 2003
1:35 pm
1724
Yeah, I had an real arguement with my var over ctrl-C and ctrl-V It stops working if you have something selected in the schematic you cannot patse a value into...
Jonathan Hurst
jackolantern26
Offline Send Email
May 5, 2003
2:07 pm
1725
Hi all We use DxDesigner at a very basic level, and do not currently link it with our Agile system. We also do not have the variant manager nor DxDatabook....
richard moffat
rmrm68rmrm
Offline Send Email
May 6, 2003
4:50 am
1726
I am having problems with an installation of ePD 2.0. I had to run Configurator under my profile as the user, although set to Administrator, could not run it....
David Rocke
davidrocke
Offline Send Email
May 7, 2003
4:22 pm
1727
Here you go Dave: Error - vspmsg-w-5598 plotting disabled, check wdir and sysplt environment variables. Cause: If the users EPD_LOCAL path has been changed or...
Fernsebner, Dan
dfernseb
Offline Send Email
May 7, 2003
4:37 pm
1728
Hi All, Anyone know a way to correct the grid? I have a schematic and some briliant person decided to place all the parts on a grid of 1.. I use a grid of 10,...
Jonathan Hurst
jackolantern26
Offline Send Email
May 8, 2003
10:19 am
1729
Jonathan, Trying using the viewdraw command line command "snap". You can't undo the change, so make sure you save a copy of your design before performing the...
Fernsebner, Dan
dfernseb
Offline Send Email
May 8, 2003
11:24 am
1730
Set the grid you desire first, and then type SNAP on the command line. Some cleanup is probably required, but it is usually effective. You may want to run...
Gary Lameris
glameris
Offline Send Email
May 8, 2003
2:43 pm
1731
I am looking for advice on purchasing EDA software for switch mode power supply development. Does anybody use DxAnalog for switching waveform analysis? I am...