5937
Well, for the first time, I am in need of copying a part of a dxd schematic to another project. Problem is, when I mark all the components/nets I need and...
stefansjensen
Offline Send Email
Jul 4, 2007
8:46 am
5938
Hi BR, ... I assume you have both schematics open using the same DxD "session"? You can select things in one of two ways, or a combination of the two. Select...
Austin Franklin
austinfranklin
Offline Send Email
Jul 4, 2007
11:36 am
5939
If you open a second sheet, have two sheets open, then you can copy and paste symbols and nets. The following is from Mentor Technote mg39844 - Set the Select...
John Warm
johnwarm
Offline Send Email
Jul 4, 2007
12:32 pm
5940
Hello Stefan, The right way is COPY the Schematic files from the first project to the second Project. You Can find the Schematics file in SCH directory in the...
fintzyossi
Offline Send Email
Jul 4, 2007
5:48 pm
5941
HI, You want to copy parts of sch from project A to project B: 1) Go to the sub-directory of project A make a copy of the file sheets that you want to copy. 2)...
Hugh Simpson
hsimpson_tri...
Offline Send Email
Jul 4, 2007
5:53 pm
5942
Along with the schematic sheets, you will need any symbols from that schematic as well copied into the SYM directory of your current project. Regards, Austin ...
Austin Franklin
austinfranklin
Offline Send Email
Jul 4, 2007
6:48 pm
5943
Hi Hugh, 3) Rename the new sheets to sch.next_number_is seq. The sheets you want to copy from/to don't have to be in the same schematic, you can have two...
Austin Franklin
austinfranklin
Offline Send Email
Jul 4, 2007
6:51 pm
5944
Well i had this problem the other day, i was in a hurry so i hacked it, i just copied the sheet file that had the stuff i wanted on it into the project...
Hal Glenn
hal9000hal
Offline Send Email
Jul 4, 2007
10:40 pm
5945
you can also just add the second schematic in your library path and open it as a schematic, and then copy/paste whatever you want from the second schematic. ...
Greg
siriusbliss
Offline Send Email
Jul 5, 2007
4:14 am
5946
Hi I have some designs being imported from Protel to DxDesigner. I would like to add the parts as resultign from the import to the central library Any...
davidepalmy
Offline Send Email
Jul 5, 2007
3:05 pm
5947
Austin, Thank You, I just used the same name so i could just have one sch open. Hugh Austin Franklin <yahoogroups@...> wrote: Hi Hugh, 3) Rename the...
Hugh Simpson
hsimpson_tri...
Offline Send Email
Jul 5, 2007
8:46 pm
5948
Anyone know how to do this? It is really annoying that PADS Layout and Router are not equivalent in this regard. I took a quick look through the...
daviddalke
Offline Send Email
Jul 6, 2007
2:19 am
5949
Hi, I am new for Dxdesigner. I found one problem in my design, I have received one converted schematic (Cadstar to Dxd) from our customer. Some part of it I...
atultakbhate
Offline Send Email
Jul 10, 2007
11:54 am
5950
The ref des prefix is stored in the Parts database. When creating library parts, the default for that prefix is "U" so I suspect that you need to look at your...
john_ruf@...
j_ruf_agilent
Offline Send Email
Jul 10, 2007
4:43 pm
5951
Hello, Has anyone been able to set the font style from FIXED to anything else using a script? I am trying to update the settings automatically when i staer a...
John Bellicitti
jbellicitti
Offline Send Email
Jul 11, 2007
11:31 pm
5952
Yes, you can set the fontstyle in the viewdraw.ini that you use for new designs. We use a scheme where we have a WDIR with a personal area, a corporate area...
john_ruf@...
j_ruf_agilent
Offline Send Email
Jul 11, 2007
11:51 pm
5953
I have not seen the ability to do this. This change is a registry change, so it only needs to happen once on any machine using the tools. Thanks, Vern Wnek ...
Vernon Wnek
vmwnek
Offline Send Email
Jul 12, 2007
12:35 am
5954
Hi John, Thanks for the inputs. I have the environment that you outlined. What I noticed is that when you open a new design and for whatever reason you open...
John Bellicitti
jbellicitti
Offline Send Email
Jul 13, 2007
4:20 pm
5955
That's strange. I just created a new design, added a part from DxDatabook and the font was exactly right the first time (it is font 5 and it has been remapped...
john_ruf@...
j_ruf_agilent
Offline Send Email
Jul 13, 2007
4:29 pm
5956
Hi to all, I would be interested in peoples views about DxDesigner compared to Powerlogic the pros and cons etc. I have been tasked with doing an evaluation...
gazzoouk
Offline Send Email
Jul 16, 2007
11:10 am
5957
Hi Gary, ... I'm not exactly sure what you mean by "class rules" but DxD certainly does support putting nets in a class (PCBCLASS), and assigning rules to the ...
Austin Franklin
austinfranklin
Offline Send Email
Jul 16, 2007
1:42 pm
5958
You can copy the converted symbols in a central library and then replace in your schematic all symbols. I don't know if there is a better way. I'm very...
Andrea Tognocchi
atomixit
Offline Send Email
Jul 16, 2007
2:54 pm
5959
Hi, Does this "Connectivity Spreadsheet Editor" take forever in DxD for others? Any time I select the component or net icon on the top, it goes away for some...
Austin Franklin
austinfranklin
Offline Send Email
Jul 17, 2007
5:28 pm
5960
Hi Austin it is exactly as you describe, assign nets to a class then assign rules between the classes. regards Gary ... certainly does ... the ... decided ... ...
gazzoouk
Offline Send Email
Jul 17, 2007
5:39 pm
5961
I used Pads Logic for many years, and recently switched to DxDesigner. I have to say I prefer DxDesigner. It is a lot more flexible / powerful. Of course, that...
Bowden, Ivor
bowdenivor
Offline Send Email
Jul 17, 2007
5:43 pm
5962
I have had no trouble selecting things in the spreadsheet editor. I would have noticed something that bad. ________________________________ From:...
john_ruf@...
j_ruf_agilent
Offline Send Email
Jul 17, 2007
6:02 pm
5963
I assumed you have a relatively large design. I have seen this before in 2004, but DxD 2005SP3 release has much better overall performances. HTH! Sylvain ... ...
Sylvain Labrecque
slabrek
Offline Send Email
Jul 17, 2007
6:16 pm
5964
Hi John, Selecting things works fine, it's when I select the two modes...component or net it takes that long. It's the two buttons along the top...the third...
Austin Franklin
austinfranklin
Offline Send Email
Jul 17, 2007
6:24 pm
5965
Mine pops up with an error message that says that I am not licensed for this option. If I close the pop-up it goes ahead and lets me do everything anyway. If I...
tcwaggoner
terrencewagg...
Offline Send Email
Jul 17, 2007
6:39 pm
5966
No, those buttons create no performance problem for me. They respond instantly. I have a medium size design (about 12 C size schematic sheets with stuff and...
john_ruf@...
j_ruf_agilent
Offline Send Email
Jul 17, 2007
7:03 pm
Messages 5937 - 5966 of 7589   Oldest  |  < Older  |  Newer >  |  Newest