Well, for the first time, I am in need of copying a part of a dxd schematic to another project. Problem is, when I mark all the components/nets I need and...
Hi BR, ... I assume you have both schematics open using the same DxD "session"? You can select things in one of two ways, or a combination of the two. Select...
If you open a second sheet, have two sheets open, then you can copy and paste symbols and nets. The following is from Mentor Technote mg39844 - Set the Select...
Hello Stefan, The right way is COPY the Schematic files from the first project to the second Project. You Can find the Schematics file in SCH directory in the...
HI, You want to copy parts of sch from project A to project B: 1) Go to the sub-directory of project A make a copy of the file sheets that you want to copy. 2)...
Along with the schematic sheets, you will need any symbols from that schematic as well copied into the SYM directory of your current project. Regards, Austin ...
Hi Hugh, 3) Rename the new sheets to sch.next_number_is seq. The sheets you want to copy from/to don't have to be in the same schematic, you can have two...
Well i had this problem the other day, i was in a hurry so i hacked it, i just copied the sheet file that had the stuff i wanted on it into the project...
you can also just add the second schematic in your library path and open it as a schematic, and then copy/paste whatever you want from the second schematic. ...
Hi I have some designs being imported from Protel to DxDesigner. I would like to add the parts as resultign from the import to the central library Any...
Austin, Thank You, I just used the same name so i could just have one sch open. Hugh Austin Franklin <yahoogroups@...> wrote: Hi Hugh, 3) Rename the...
Hi, I am new for Dxdesigner. I found one problem in my design, I have received one converted schematic (Cadstar to Dxd) from our customer. Some part of it I...
The ref des prefix is stored in the Parts database. When creating library parts, the default for that prefix is "U" so I suspect that you need to look at your...
Hello, Has anyone been able to set the font style from FIXED to anything else using a script? I am trying to update the settings automatically when i staer a...
Yes, you can set the fontstyle in the viewdraw.ini that you use for new designs. We use a scheme where we have a WDIR with a personal area, a corporate area...
I have not seen the ability to do this. This change is a registry change, so it only needs to happen once on any machine using the tools. Thanks, Vern Wnek ...
Hi John, Thanks for the inputs. I have the environment that you outlined. What I noticed is that when you open a new design and for whatever reason you open...
That's strange. I just created a new design, added a part from DxDatabook and the font was exactly right the first time (it is font 5 and it has been remapped...
Hi to all, I would be interested in peoples views about DxDesigner compared to Powerlogic the pros and cons etc. I have been tasked with doing an evaluation...
Hi Gary, ... I'm not exactly sure what you mean by "class rules" but DxD certainly does support putting nets in a class (PCBCLASS), and assigning rules to the ...
You can copy the converted symbols in a central library and then replace in your schematic all symbols. I don't know if there is a better way. I'm very...
Hi, Does this "Connectivity Spreadsheet Editor" take forever in DxD for others? Any time I select the component or net icon on the top, it goes away for some...
Hi Austin it is exactly as you describe, assign nets to a class then assign rules between the classes. regards Gary ... certainly does ... the ... decided ... ...
I used Pads Logic for many years, and recently switched to DxDesigner. I have to say I prefer DxDesigner. It is a lot more flexible / powerful. Of course, that...
I assumed you have a relatively large design. I have seen this before in 2004, but DxD 2005SP3 release has much better overall performances. HTH! Sylvain ... ...
Hi John, Selecting things works fine, it's when I select the two modes...component or net it takes that long. It's the two buttons along the top...the third...
Mine pops up with an error message that says that I am not licensed for this option. If I close the pop-up it goes ahead and lets me do everything anyway. If I...
No, those buttons create no performance problem for me. They respond instantly. I have a medium size design (about 12 C size schematic sheets with stuff and...