Help-I have been with Dx Designer since it was View Draw. I am now with a company that only uses Power Logic. My Question is "Is there a software out there...
Hi, it could be even more simply: in the command line of dxdesigner enter avvis ATTRIBUTE_NAME to make attributes visible on the sheet it also works with...
I started a new job But I inherited a machine that the previously user reconfigured the right mouse button to use strokes like some MCAD systems. Not being...
In the project settings, in the 'Project' tab, you have the option to switch off the strokes completely OR use the middle button for strokes. Regards, Manuel...
Thanks It was one of those silly things you know it is easy to do but there just is no way to find it when you REALLY need it ... -- "We are all born ignorant,...
In that same project settings > project tab you can change your stroke mouse button from right to middle and have the best of both worlds. I find strokes ...
Hi, Has anyone had any success in running DxDesigner on Windows Vista. Did it work? Any tricks to it? Any suffering involved? Thinking about a new laptop...
window emulator on linux. forgot the name??? ... ____________________________________________________________________________________ Need a vacation? Get...
Hi all, I am just beginner of Dxdesigner. I suppose that viewdraw is old version of Dxdesigner, izzit ? if they are the same, i want to know how to bind "pop"...
Hi, All I've been through the help menu's but with no luck. I have a MS ACCESS database as the library source file. No issue's with bring in parts, or...
Hi Ian, If I understand you correctly, you should just be able to "right Click" inside the DxDatabook Window, select "Edit Configuration" and then select ...
Ian, What you need to do is perform a "Live Verification" on your schematic. There is a Live Verification button on the left side of the DxDatabook window. ...
Thanks, I found the app note 10028. seems to work apart from any part that has mutiple symbols used. I have IC's that are split into 6 different parts, with...
Having abit of an annoying problem. When searching the DxDB for components, it always truncates my component list to 40 matches. The weird thing is that on my...
Below I've pasted a procedure correctly running in VB6 to read sheet attributes in dxdesigner. Dim Valore, Nome as String Set MyVdraw1 = GetObject(,...
Hi Andrea, The collections in DxDesigner's COM interface do not support the .Net IEnumerable interface, so you cannot use the For Each construct in .Net...
Thanks John, it works Andrea ... Thanks John, it works Andrea At 16.09 18/10/2007, you wrote: Hi Andrea, The collections in DxDesigner's COM interface do not...
Ian, If you are happy that your attributes have been updated in the Databook window. Select the component on your schematic then find the record in Databook...
I managed to convince my colleagues at the consulting company where I work to share a netlist compare tool that I developed and we have been using in our...
Hi all, I am about to start a heirachical schematic in dxdesigner as opposed to a flat and would like to know how I would start to go about it is there any...
There are problems with hierarchy. With only 10 sheets, don't do it. Mike Chombeau Validation Hardware Oregon 503-264-1808 ________________________________ ...
Hi Mike, ... What are these problems? I've been doing hierarchical schematics for what, near 17 years since the days of DOS ViewDraw 4.1...I haven't seen any ...
1. DxPDF doesn't create XREF hyperlinks across hierarchy. (biggest problem) 2. These schematics are difficult to trace in the lab. None of our users like them....
Hi Mike, Thanks for the list. ... problem) OK, we never used (or needed to use) those. But, that seems like it could be a prohibitive bug for someone who...
Hi, Anyone guide to me, how to create netlist from dxdesigner to pads. While create netlist what kind of modification done in symbol leavel and also how to...
Hi dazzakb, Hierarchical design is fairly straightforward. On your "overall block schematic" sheet, you will have one block for each subcircuit. These blocks...
Hello all, Here is just one comment on top. If you want to use the same lower level hierarchic schematic multiple times, you have to enable the OAT mode in the...