Does anyone know how to add a sym to a sch that will produce QTY=0 in partlister output? I tried PARTS=0 attribute but that does not seem to work?...
sbesser65
Offline Send Email
Dec 4, 2007
5:28 pm
6182
Try reading the Technote below: http://supportnet.mentor.com/reference/technotes/public/technote.cfm?tn=mg39738 Regards, Keith Vieira ... From: sbesser65...
Keith Vieira
breaka19
Offline Send Email
Dec 4, 2007
5:38 pm
6183
If this is what you're trying to do...this info is from the Mentor technotes: Note: This process only works on a non-Central Library project. The existence of...
Austin Franklin
austinfranklin
Offline Send Email
Dec 4, 2007
5:44 pm
6184
No. We already us the CLASS=LAB to filter parts from showing up in the partslist and/or the netlist. I am trying to find a way for a part to show up in the...
sbesser65
Offline Send Email
Dec 4, 2007
6:59 pm
6185
You can also edit the part and copy it and make the new part an Annotative part so it shows but will not go to partslist ... -- " You can not give people what...
Les Embrey
lesismorem
Offline Send Email
Dec 4, 2007
7:00 pm
6186
What not just add an additional attribute the part that acts as a flag - BOM=NO_ORDER _____ From: DxDesigner_Users@yahoogroups.com ...
Daniel Fernsebner
dfernseb
Offline Send Email
Dec 4, 2007
7:38 pm
6187
Then, I don't think you can have a part in the parts list with a quantity 0. To get into the parts list, it has to have a REFDES and every unique REFDES is...
Austin Franklin
austinfranklin
Offline Send Email
Dec 4, 2007
8:19 pm
6188
Steven why have a qty of 0 when you need 1 doc not 0 docs ? just add the test procedure doc as a part like any other part it has a qty of 1 and still needs to...
Justin Parise
vertu1965
Offline Send Email
Dec 5, 2007
3:00 am
6189
Steven, What I have done in the past is to make the REFDES start with a number (such as 0?, 1?, etc.). This causes these items to show up at the top of the...
Dan Shupe
d_r_shupe
Offline Send Email
Dec 5, 2007
4:07 pm
6190
This is a reasonable request. Our documentation policy calls for us to include all of the related product documentation as a "reference" item in the BOM. In...
wo1n
Offline Send Email
Dec 5, 2007
4:10 pm
6191
... software. I've been ... out in a ... attributes) ... is to be ... without any ... There also may ... standard to ... call, or ... Hi Glen- Did you ever...
fullmaneman
Offline Send Email
Dec 6, 2007
2:10 am
6192
Hi, I am looking for Danny Holton, who has help me with myh project in the past. If you know of Danny Holton please get a hold of me. If I can't find him then...
Hugh Simpson
hsimpson_tri...
Offline Send Email
Dec 6, 2007
3:57 am
6193
Ken, I highly recommend that you develop an Excel macro for this. It doesn't require knowledge of any scripting languages (although Excel does record the...
Dan Shupe
d_r_shupe
Offline Send Email
Dec 6, 2007
1:39 pm
6194
One method to do this is place the XY position as an attribute in PADS using a script to derive the information and place it in the PADS database as an...
Gary Lameris
glameris
Offline Send Email
Dec 6, 2007
2:16 pm
6195
yes- I was thinking along the lines... but in this case I'm using Allegro- What I've done so far is take a place.txt report, and re-formatted it to make a...
fullmaneman
Offline Send Email
Dec 6, 2007
10:39 pm
6196
Hi, I am looking for Danny Holton, who has help me with myh project in the past. If you know of Danny Holton please get a hold of me. If I can't find him then...
Hugh Simpson
hsimpson_tri...
Offline Send Email
Dec 8, 2007
9:19 pm
6197
We need to replace specific character in the partlist report such as netlist (VIewPCB). Example: In the NETLIST configuration file (.cfg) we have: ...
fintzyossi
Offline Send Email
Dec 12, 2007
9:24 pm
6198
I'm new in dxdesigner automation. I'm trying to write a simple application is vb.net using the viewdraw object. I have 2 problems I can't resolve. first: My...
izickk
Offline Send Email
Dec 18, 2007
9:58 pm
6199
Hi, To get the active project location without starting DxDesigner, you can look in the registry: ...
Dube, John
jdube1234
Offline Send Email
Dec 19, 2007
2:05 pm
6200
Thank you very much, it helped. What does it means when Application.ActiveView.Block.GetName method return 0? Is there defined outputs for this method that...
izickk
Offline Send Email
Dec 19, 2007
6:29 pm
6201
Do you have a schematic open in DxDesigner? Maybe there is more than one viewdraw.exe process running? John ... From: DxDesigner_Users@yahoogroups.com ...
Dube, John
jdube1234
Offline Send Email
Dec 19, 2007
8:32 pm
6202
Does anyone have any information about a course/ seminar or any kind of help available on that subject?...
izickk
Offline Send Email
Dec 20, 2007
12:12 pm
6203
I can't reproduce the same problem. Now everything seems to work fine. And for your question, Yes the schematic is open and there is only one viewdraw.exe...
izickk
Offline Send Email
Dec 20, 2007
12:12 pm
6204
Hi, Anyone know how to generate the following format automatically? My PLM software's Tech support says this is required... What I have today... ...
miwalker
Offline Send Email
Dec 28, 2007
2:26 pm
6205
Mike, your partlist ini file is setup to compress mode. You can change the partlist.ini file line REFDES_MODE 0 to REFDES_MODE 1 (expand mode). You will get:...
Benny
bennyrabin
Offline Send Email
Dec 29, 2007
5:41 pm
6206
Greetings, Please Help I cant open dx designer after accedently changeing my computer system clock. I had the calender up to check a date and then clicked ok...
Mark Degregg
greggula
Offline Send Email
Jan 4, 2008
11:52 am
6207
See Technote MG62615 and download the fixfut utility that is linked there. ... ______________________________________________________________________...
urbane_maust
Offline Send Email
Jan 4, 2008
1:04 pm
6208
Reboot the machine, check for any file with future date (i.e.: Jan 5th) and erase them. Regards Lucio ________________________________ From:...
Valle, Lucio
lucio_valle@...
Send Email
Jan 4, 2008
1:09 pm
6209
It was supposed to be in the summer, then Q4, now? Mike Chombeau Validation Hardware Oregon 503-264-1808 . ...
Chombeau, Mike
mikechombeau
Offline Send Email
Jan 4, 2008
5:52 pm
6210
I have 2 wires, 1 of which is to be used to shield the other wire. In the schematic I can only show them as 2 seperate wires, with no apparant link between...