I am having a problem placing our company logo in the sheet border. It seems to appear/disappear randomly viewed on screen and when I print or make pdf's. Has...
Is there a way to change the order the page/zone cross reference is displayed. With my scout file the cross reference is displayed as page first then row then...
How are you inserting the object? When you insert a picture into the schematic, it actual saves that information in the sch/OLE directory. If other team...
When you import it in do you do a combine on it and save it to your library. Then you can call it up and scale it to size. I usually put it on the silk layer...
Hi, I am new to DxDesigner/DxDatabook and would appreciate any help I ca get. I am unable to verify a component. I created a new config file with all my...
That was simple enough. I am just learning DxDesigner so it is likely I will be asking some pretty basic questions. Thanks ... format_entry ... page...
I insert it at the symbol editing level by edit, insert object menu. Yes I do see the OLE folder created and at this point I am the only one accessing this...
Hi Ernie, I tried checking off some attributes from the 'load' tab within edit library configuration, and it worked - Thanks! What is the point of that 'load'...
Those are the attributes that the verify tool uses to find a part in the dxdatabook, you should only need the partnumber and symbol attribute to verify. Ernie ...
The "load" attributes are also what the verify tool checks to see match in the database. You might also want to check your footprint or value attributes to...
I do something simpler, I just attach a little piece of net to the "NC" pins and label the net "NC". I then copy that tiny piece of net anywhere I need a...
OLE objects do not work well in DxDesigner. You will be better off if you create an outline of your company logo out of lines, circles, etc.. Bob H ... From:...
... In The new version EE2007 the schematic DXdesigner is replace By another schematic tools ( similary of DCcapture ) need to do convertion of you library and...
It's already here, was posted on the Mentor site last week. Thanks, Vern Wnek Manager, PCB Layout, ENG BU Office: 949-926-6418 x66418 Cell: 714-917-5855 Email:...
Be careful with this technique. Labeling a net the same name as another net makes a real connection between them. I don't think you want all your NC nets...
I believe that if you add the "NC" attribute to the net, DxDesigner Create Netlist won't generate "Warning 6094" (Pin not connected), but it will instead...
Tony is correct. I am told the third party netlist version will arrive shortly. Thanks, Vern Wnek Manager, PCB Layout, ENG BU Office: 949-926-6418 x66418 Cell:...
Hi, The point, for me at least, is to have pins that I do NOT want connected in the netlist not show up as warnings in the netlist generation. And, for single...
One additional note about the NC thing: I am using the DxDesigner-Expedition workflow, and Expedition has the nice feature to assign net-names (Net0-xxx) to...
I agree, Austin, the point is to find single pin nets that are supposed to be connected to other pins but are accidentally isolated. I think the easiest way is...
There is a attr.pdf file in the Mentor graphics install directory that has information on the NC attribute. Jerry Eller GE Fanuc Intelligent Platforms ...
I have seen this question asked before but I still don't fully understand how the Hetero Type 2 works. We would like to build, for example, a 4 gate opamp...
Scott, to my opinion, it is important NOT to use the SIGNAL attribute, but to add a power pin. After a chip was connected to a wrong power source, and I did...
Good idea Austin! Benny <mailto:benny@...>* <http://www.rts-development.com/>* ... Good idea Austin! Benny Austin Franklin wrote: Hi, The point, for...