Good idea Austin! Benny <mailto:benny@...>* <http://www.rts-development.com/>* ... Good idea Austin! Benny Austin Franklin wrote: Hi, The point, for...
6265
Benny
bennyrabin
Feb 11, 2008 11:37 pm
Scott, to my opinion, it is important NOT to use the SIGNAL attribute, but to add a power pin. After a chip was connected to a wrong power source, and I did...
6264
sdl2112
Feb 11, 2008 10:58 pm
I have seen this question asked before but I still don't fully understand how the Hetero Type 2 works. We would like to build, for example, a 4 gate opamp...
6263
Eller, Jerry (GE Indu...
jerry.eller
Feb 11, 2008 8:32 pm
There is a attr.pdf file in the Mentor graphics install directory that has information on the NC attribute. Jerry Eller GE Fanuc Intelligent Platforms ...
6262
Bowden, Ivor
bowdenivor
Feb 11, 2008 7:38 pm
I agree, Austin, the point is to find single pin nets that are supposed to be connected to other pins but are accidentally isolated. I think the easiest way is...
6261
Manuel Koch
makoc79
Feb 11, 2008 6:24 pm
One additional note about the NC thing: I am using the DxDesigner-Expedition workflow, and Expedition has the nice feature to assign net-names (Net0-xxx) to...
6260
Austin Franklin
austinfranklin
Feb 11, 2008 6:24 pm
Hi, The point, for me at least, is to have pins that I do NOT want connected in the netlist not show up as warnings in the netlist generation. And, for single...
6259
Vernon Wnek
vmwnek
Feb 11, 2008 6:10 pm
Tony is correct. I am told the third party netlist version will arrive shortly. Thanks, Vern Wnek Manager, PCB Layout, ENG BU Office: 949-926-6418 x66418 Cell:...
6258
Bowden, Ivor
bowdenivor
Feb 11, 2008 6:09 pm
I believe that if you add the "NC" attribute to the net, DxDesigner Create Netlist won't generate "Warning 6094" (Pin not connected), but it will instead...
6257
Chombeau, Mike
mikechombeau
Feb 11, 2008 5:59 pm
Be careful with this technique. Labeling a net the same name as another net makes a real connection between them. I don't think you want all your NC nets...
6256
avjohn@...
avjohn01
Feb 11, 2008 5:50 pm
Just be aware that's it's only for Expedition. The PADs and Vendor Independent versions haven't been released yet. Tony ... Tony John...
6255
Vernon Wnek
vmwnek
Feb 11, 2008 5:41 pm
It's already here, was posted on the Mentor site last week. Thanks, Vern Wnek Manager, PCB Layout, ENG BU Office: 949-926-6418 x66418 Cell: 714-917-5855 Email:...
6254
aljcidx
Feb 11, 2008 10:08 am
... In The new version EE2007 the schematic DXdesigner is replace By another schematic tools ( similary of DCcapture ) need to do convertion of you library and...
6253
azheninger
Feb 11, 2008 4:32 am
OLE objects do not work well in DxDesigner. You will be better off if you create an outline of your company logo out of lines, circles, etc.. Bob H ... From:...
6252
Rich Tanner
rich_tanner
Feb 10, 2008 10:56 pm
I do something simpler, I just attach a little piece of net to the "NC" pins and label the net "NC". I then copy that tiny piece of net anywhere I need a...
6251
babyjo11
Feb 8, 2008 11:30 pm
Thanks so much guys! The user manual doesn't really go into much detail with this, so i"m really glad for your assistance =) jolyn...
6250
avjohn@...
avjohn01
Feb 8, 2008 10:09 pm
The "load" attributes are also what the verify tool checks to see match in the database. You might also want to check your footprint or value attributes to...
6249
Quantie, Ernie
equantie
Feb 8, 2008 9:34 pm
Those are the attributes that the verify tool uses to find a part in the dxdatabook, you should only need the partnumber and symbol attribute to verify. Ernie ...
6248
babyjo11
Feb 8, 2008 9:27 pm
Hi Ernie, I tried checking off some attributes from the 'load' tab within edit library configuration, and it worked - Thanks! What is the point of that 'load'...
6247
sdl2112
Feb 8, 2008 9:22 pm
I insert it at the symbol editing level by edit, insert object menu. Yes I do see the OLE folder created and at this point I am the only one accessing this...
6246
sdl2112
Feb 8, 2008 9:02 pm
That was simple enough. I am just learning DxDesigner so it is likely I will be asking some pretty basic questions. Thanks ... format_entry ... page...
6245
Quantie, Ernie
equantie
Feb 8, 2008 8:49 pm
What database attributes did you select to load? Select only the part number attribute and the symbol attribute. also make sure you are placing the...
6244
babyjo11
Feb 8, 2008 8:31 pm
Hi, I am new to DxDesigner/DxDatabook and would appreciate any help I ca get. I am unable to verify a component. I created a new config file with all my...
6243
Les Embrey
l.embrey
Feb 8, 2008 8:15 pm
When you import it in do you do a combine on it and save it to your library. Then you can call it up and scale it to size. I usually put it on the silk layer...
6242
Chombeau, Mike
mikechombeau
Feb 8, 2008 6:26 pm
Just edit your scout.ini file and change the order of the format_entry line Mike Chombeau Validation Hardware Oregon 503-264-1808 ...
6241
Chombeau, Mike
mikechombeau
Feb 8, 2008 6:24 pm
How are you inserting the object? When you insert a picture into the schematic, it actual saves that information in the sch/OLE directory. If other team...
6240
sdl2112
Feb 8, 2008 6:10 pm
Is there a way to change the order the page/zone cross reference is displayed. With my scout file the cross reference is displayed as page first then row then...
6239
sdl2112
Feb 8, 2008 6:09 pm
I am having a problem placing our company logo in the sheet border. It seems to appear/disappear randomly viewed on screen and when I print or make pdf's. Has...
6238
volker_hetzer
Feb 4, 2008 1:51 pm
Hi! Looks much better now. Thanks a lot! Volker ... levels. ... sheets. ... sheet. ... sheet. ... 15,16,16,16....
6237
Jason Stubbs (ECC)
jpstubbs
Feb 1, 2008 1:33 pm
Volker, look in the scout.ini file for the following section and change the ... scope_level_to_level true | Reference objs on other levels. ...