Re:Potential Health Risk from Cathode Ray Tube



---Yes I only want to demo electrons. I did use this three or so times a year
for two years but not for any extended periods. I was sold this setup by
scisupply.





Fri Oct 9, 2009 1:41 am

rrquay
Offline Offline
Send Email Send Email

Forward
Message #17030 of 17836 |
Expand Messages Author Sort by Date

I once again ask for the wisdom of those on this site. I am a Physics teacher and often use a cathode ray tube to display how electrons were discovered by JJ...
rrquay
Offline Send Email
Oct 8, 2009
11:45 pm

Yes, it is an X-Ray tube. What is the High Voltage generated? See this article : http://tech.groups.yahoo.com/group/XRL/message/58 NOT A TOY! Geo ... From:...
Geo>K0FF
K0FF
Offline Send Email
Oct 8, 2009
11:56 pm

As for the health hazards, no comment; however, a GM Survey meter is inadequate for measuring X-rays. The problem is X-ray machines can produce a pulsed...
Chris Cavanaugh
night427
Offline Send Email
Oct 9, 2009
12:11 am

The induction coil is 10,000 kv...
rrquay
Offline Send Email
Oct 9, 2009
12:15 am

Sorry 10 KV...
rrquay
Offline Send Email
Oct 9, 2009
12:19 am

fine, It may be higher than that on peaks. even a 10 kVp X-Ray is penetrating. High Voltage + Vacuum tube= X-Rays. Good luck with that. Geo ... From: "rrquay"...
Geo>K0FF
K0FF
Offline Send Email
Oct 9, 2009
12:25 am

I used to work at a science museum that had one of those Van de Graaf generators- a particle accelerator. A graduate physics student was working with it and...
spacedad2
Offline Send Email
Oct 9, 2009
1:44 am

Try to find a power source offering no more than 5 Kv to the tube. Anything higher and you risk x-ray output. There are a few micro type supplies that may do...
Eric Tv
astro4565t
Offline Send Email
Oct 9, 2009
1:19 am

Thank you. That makes sense. Is there a way to calculate the frequency of the xrays produced by different voltages? I assume that this production is caused by...
rrquay
Offline Send Email
Oct 9, 2009
1:31 am

Braking (Bremsstrahlung) as well as characteristic X-Rays. If all the materials are low Z, the characteristic X-Rays will be very low energy level. Brems will...
Geo>K0FF
K0FF
Offline Send Email
Oct 9, 2009
1:44 am

OK but does secondary require a change in direction. I'm thinking Compton scattering here where momentum is conserved. ________________________________ From:...
Richard Quay
rrquay
Offline Send Email
Oct 9, 2009
1:53 am

Correct. In Compton scattering, the original photon radiation changes direction losing ( or in rare cases, gaining-) energy (inelastic scattering). In...
Geo>K0FF
K0FF
Offline Send Email
Oct 9, 2009
2:13 am

I am looking for someone with an interest in radiation education as opposed to disinformation who lives near Waterport, NY to do some local area research....
Roger Helbig
madcolonel
Offline Send Email
Oct 9, 2009
8:47 am

x rays produced at 5kv will make it through the glass envelope.??? ... From: Eric Tv To: GeigerCounterEnthusiasts@yahoogroups.com Sent: Thursday,...
arthurok
arthurok_2000
Online Now Send Email
Oct 9, 2009
1:25 am

I think the point is to accelerate electrons, not to make X-Rays. Geo ... From: arthurok To: GeigerCounterEnthusiasts@yahoogroups.com Sent: Thursday, October...
Geo>K0FF
K0FF
Offline Send Email
Oct 9, 2009
1:34 am
rrquay
Offline Send Email
Oct 9, 2009
1:41 am
rrquay
Offline Send Email
Oct 9, 2009
1:47 am

I have had success with as little as 2 Kv, again with a small plasma globe supply. The only drawback was that the fluorescence within the tube was too faint...
Eric Tv
astro4565t
Offline Send Email
Oct 9, 2009
3:08 pm

Video is a poor substitute, but is definitely the media of today. When I was a little kid, our science teacher performed and experiment that graphically ...
Geo>K0FF
K0FF
Offline Send Email
Oct 9, 2009
3:33 pm

Interesting demo Geo, A similar technique involving a sparkplug and the gas tank of a car or bike was used to deal with some very naughty people in the Middle...
Brian Thwaites
brian_thwaites
Offline Send Email
Oct 10, 2009
7:14 pm

Hello, the danger to YOU is much more than your students because 1. you repeat this demo, they don't 2. you're closer to it That being said, 10kV x-rays will...
revtkatt
Offline Send Email
Oct 19, 2009
9:51 pm