I recently received an Eberline PNR-4 and Neurton probe. I am in need of a manual and a cable to connect the PRN-4 to the Probe which has a bnc connector. I...
May I ask for help with postal regulations? I have a number of CDV-700 case bottoms, with their test sources. Some of these may be worth something as...
Whatever you decide, I'd like a few test sources. You can ship the cases to me either as replacement parts of for dismantling. I think. Since several ...
... What you describe here applies to EVERY count tick, not just sparse ones. I do not have the same effect here with my equipment. sounds like overdriving the...
I have a CDV-700 without a G-M tube. It is also missing its check source. I also have a Ludlum 44-9 Detector probe that I would like to have installed on the...
... ones. Yep that is true, I just cannot get reproducable result , if i place the geigercounter just a bit closer or further from the mic the number of clicks...
Mic? I never heard of anyone trying it wirh a miccrophone, that's why there is a data port on the LENi, for direct hookup. Good luck. Geo ... sparse ... number...
I have a CDV-700 with a meter that sticks. It appears the case is glued together. Is there a way to dissolve the glue, or maybe pry apart the case? Thanks;...
I have an instrument that uses an "all plastic" sealed meter that was very "sticky" when I received it. It had been subjected to high G at some point and one...
I used this method to extract the 50 ua meter movement from a plastic CDV715 meter so I could replace a bad movement in an Eberline E-120 I had. I took an old...
Hi folks, here's Daniel from Slovakia, maybe the older members still remeber me :). I just got an Eberline E-140N with a HP-210L probe and it looks to work...
The four screws are 5/64 inch recessed, hexagonal setscrews that hold the pancake element centered in the assembly. Indeed, in order to tighten the screws...
OK, thanks for the instructions. I knew this wouldn't be that easy. But in case I only need to remove the upper shielding part (black, made out lead), I need...
There are three pieces that make up the assembly, viz. 1) The outer aluminum piece with four threaded holes for the setscrews. 2) The inner lead shield to...
Hi Daniel - I can't help but wondering - was the ebay seller "plsfreelance"?? He shipped a box to me the same way - almost nothing to keep stuff from flying...
Hi Daniel the HP-210 is a real nice probe I have one also wish I could help you out with fixing it but I have necer had one apart. I do have though two PDF ...
Hi Mark, yes the seller is "plsfreelance" and he charged $60 for shipping that cost $30 and that was surface shipping which took 45 days! And he said he needs...
I just found those files on the Thermo Electron website. Thanks anyway. ... could help ... though two PDF ... on the 210 ... Eberline ... though. I will Email...
As a special thank you to all the list members who are keeping the hobby of amateur radiation detection alive, I'm offering a 15% discount to members of the...
Thanks for all the instructions. I openned the HP-210L probe today, the inside was looking quite simple and I was able to tighten the screw that holds the...
Does anyone know where to find manuals for Ortec Nim Bin plug-ins? Ortec charges $100 per copy for their legacy products. Does anyone have at least a...
Hi all, I finally had a chance to look at the Wallac today. It all seems to work OK. It was interesting clearing out at the racks, the the reference standard...
Very cool. I also have a calibrated '129 source! Small world....Geo ... From: Robert Atkinson To: GeigerCounterEnthusiasts@yahoogroups.com Sent: Sunday, June...
Hello, I have recently seen a Geometrics scintillator go on Ebay for some hundred dollars. It looked like a professional type of meter. Can anyone describe...
Daniel, The Geometrics unit is sensitive to naturally occuring radioactive sources of Uranium, Thorium, and Potassium. It has a built in SCA (single channel...