HydroLighteans, A new H user has just asked me if anyone has developed a frontend (in IDL, for example) that would allow him to run H under UNIX without going...
Curtis Mobley
hydrolightman
Offline Send Email
Jan 30, 2006
5:38 pm
11
I too would be very interested in trying out an interface on unix. servet ... __________________________________________________ Do You Yahoo!? Tired of spam?...
Servet
acizmeli
Offline Send Email
Jan 31, 2006
1:14 am
12
Greetings, Marcos Montes and Joe Rhea at the Naval Research Lab-DC have put together a nice tech note on selection of output depths when fluorescence or Raman...
Curtis Mobley
hydrolightman
Offline Send Email
Jan 31, 2006
6:01 pm
13
Hi everyone, In the next weeks I am going to (try to) compile the main original Hydrolight fortran code under linux/unix. Among people using the version 4.2 of...
a_chazottes
Offline Send Email
Mar 2, 2006
5:28 pm
14
Hello everybody, I would like to have more details about the way Hydrolight extrapolates the Petzold bb at other wavelengths than that of Petzold's...
sa.cizmeli
acizmeli
Offline Send Email
Aug 4, 2006
6:37 pm
15
Allow me to answer... When you choose the Petzold average particle phase function (named "avgpart.dpf") in the pull-down memu, that phase function is used at ...
Curt Mobley
hydrolightman
Offline Send Email
Aug 4, 2006
7:43 pm
16
Using the same IOP value as input with homogeneous and infinite deep water body assumption, the maximum output depth is set 1m for one run and 5m for another...
cindyzju
Offline Send Email
Aug 16, 2006
5:03 pm
17
Hi. The principal reason is as stated in the HL User's Guide. For your particular example, choosing a maximum depth implies that there are no sources below...
Marcos Montes
mmontes
Online Now Send Email
Aug 16, 2006
5:44 pm
18
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the HydroLightUsers group. File :...
HydroLightUsers@yahoo...
Send Email
Aug 25, 2006
5:11 pm
19
Hi everyone, I've submitted a file at that describes a faster version of the selpfbb subroutine. This subroutine is mostly used when there are measured values...
mmontes
Online Now Send Email
Aug 25, 2006
5:30 pm
20
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the HydroLightUsers group. File :...
HydroLightUsers@yahoo...
Send Email
Jan 18, 2007
7:43 pm
21
I have added a HydroLight Technical Note HTN5_Color.pdf discussing the conversion of spectra to CIE (x,y,Y) and RGB values. The current H4.3 version outputs...
Curtis Mobley
hydrolightman
Offline Send Email
Jan 18, 2007
7:49 pm
22
Has anyone written a MATLAB routine to read the Droot.txt file containing all the output of a standard run?...
helbigja
Offline Send Email
Feb 1, 2007
7:48 pm
23
I have one for the Mroot file. Servet...
Servet Ahmet Cizmeli
acizmeli
Offline Send Email
Feb 1, 2007
8:09 pm
24
If I use the full radiance output setting, the angle I get is below the water or in the air or depends on the which depth I am gettting from? thanks...
cindyzju
Offline Send Email
May 8, 2007
4:27 pm
25
The directions in H are defined by the partitioning of all directions into "quads", as shown in Fig 2 of the Users Guide, and as described in section 2.4 of...
Curtis Mobley
hydrolightman
Offline Send Email
May 8, 2007
5:21 pm
26
So in the full radiance output file, if the radiance is just below the water surface (like say 0), the angle in that radiance table (theda and phi) should be...
cindyzju
Offline Send Email
May 8, 2007
9:14 pm
27
Correct. Thus a direction of theta = 45 deg, phi = 90 deg, is the same direction either above or below the surface. The theta,phi coordinate system does not...
Curtis Mobley
hydrolightman
Offline Send Email
May 8, 2007
9:36 pm
28
Hi everybody, I would like to use the spectral downwelling irradiance measurements we performed above water surface instead of the Radtran sky model. With the...
Servet Ahmet Cizmeli
acizmeli
Offline Send Email
Jul 6, 2007
4:46 am
29
Servet (and all), Even though the input file for your two runs look the same, the aren't the same run. The reason is that when you select RADTRAN, it ...
Lydia Sundman
lksundman
Offline Send Email
Jul 6, 2007
12:51 pm
30
Servet and everyone, In Hydrolight (HL), not everything is controlled by the input file. Some parameters are specified in the input file. Some are specified in...
Marcos Montes
mmontes
Online Now Send Email
Jul 6, 2007
3:31 pm
31
Folks, Marcos is correct that modifying runs outside of the UI is a task that requires a lot of courage and should not be done cavalierly. I also wanted to add...
Lydia Sundman
lksundman
Offline Send Email
Jul 6, 2007
4:33 pm
32
I understand it much better now, especially after Marcos' comments. Thanks Marcos, thanks Lydia. One more question: Looking at my newly compiled incfiles.for,...
Servet Ahmet Cizmeli
acizmeli
Offline Send Email
Jul 6, 2007
5:43 pm
33
Servet, Ah, good, you found incfiles.for. When I wrote the email, I had forgotten the incfiles.for is the actual one that gets compiled. There is also a copy...
Marcos Montes
mmontes
Online Now Send Email
Jul 6, 2007
6:00 pm
34
I understand it much better now, especially after Marcos' comments. Thanks Marcos, thanks Lydia. One more question: Looking at my newly compiled incfiles.for,...
Servet Ahmet Cizmeli
acizmeli
Offline Send Email
Jul 6, 2007
6:01 pm
35
Servet, ... Note that the above steps do not perform a compilation. They merely consist of editing files. Really, I need to add a few steps: First, you should...
Marcos Montes
mmontes
Online Now Send Email
Jul 9, 2007
4:20 pm
36
Hi Marcos, Thanks a lot for your precious comments. I'll try to write a fortran routine that will read the diffuse spectral irradiance along with Edtot. best ...
Servet Ahmet Cizmeli
acizmeli
Offline Send Email
Jul 9, 2007
6:49 pm
37
It really looks like the most important information is Eddif and eddir if you look at what the skyirrad subroutine returns. Since those are the only things...
Marcos Montes
mmontes
Online Now Send Email
Jul 9, 2007
7:08 pm
38
Hello everyone, I am a new Hydrolight's user. I would like to know if there is any way to increase the maximum number of bands in the multi-wavelength ...
Elena Torrecilla
torrecillautm
Offline Send Email
Aug 2, 2007
10:42 am
39
You can change several limits, including the maximum number of wavebands within the UI. From the RUN ID form at the beginning of the UI, select "change limits"...
Lydia Sundman
lksundman
Offline Send Email
Aug 2, 2007
12:08 pm
Messages 10 - 39 of 72   Oldest  |  < Older  |  Newer >  |  Newest
Advanced
Add to My Yahoo!      XML What's This?

Copyright © 2009 Yahoo! Inc. All rights reserved.
Privacy Policy - Terms of Service - Guidelines - Help