I have the same problem with all of the special tools I created for Agilent. We are still using 5.0 because of the specific library naming convention that was...
Hey all, I changed the title of the group to the InterceptUsers group so as to not limit discussion to only Pantheon but also any of the other Intercept...
Thanks for the heads-up and BTW: good move. George ... ____________________________________________________________________________________ Never miss an email...
Hi all, I just wanted to let you know that we're working on a marketing email notifying our customer base about your users' group here. We'll put a note on our...
We are currently trying to upgrade from ePD ver 2 to ePD ver3. Is there anyone out there who has made this transition and can share what they had to change to...
Hi all- Is anyone using the Intercept Logical Interface tool? This tool allows forward and back annotation between an ORCAD schematic and a Pantheon database. ...
I've kicked this idea around with a number of Pantheon users over the years, but normally in just a one on one situation... How many of you would be interested...
... Hi Greg, I'm a newbie and could probably benefit from something like that. I'm not sure how much I could contribute since I've officially had Intercept...
Hi, I'm new in this forum, just join :) I'm interested on the pl file that you had mention. However , when I click the URL, it shown me this message Group Not...
Hi, We encounter a database who route mode remain in "ANY" regarding the mode set to "Axial" or "Axial & Diagonal". We are using Pantheon 5.0_08N. Does anyone...
Check your physical layer definitions. More than likely you have defined the layers of your board to be bonding layers. Bonding layers by definition have wires...
Hi Greg, Thanks you so much! It really cause by the Bonding layer. Another question. What is these bonding layer for? Why it always in ANY angle? Bonding is it...
Yes, bonding layers are used to draw the wires used in wire-bonding. They are always ANY angle because with wire bonds they are almost always at odd angles. ...
I have a through-hole geometry placed on the top of a board that requires a component placement keepout underneath it. I tried creating separate place_1 and...
I've seen a number of designs over the last year or so that would crash when you used the finish trace command. There's a design I was just looking at that...
Just an FYI- It is a good idea to make sure you are not in the middle of routing a trace when you save a design (PDB). The fact that the trace is selected in...
A bit of a heads up and FYI... In Mozaix and Pantheon you can define and name net classes such as "50_ohm", "audio", etc. Nets are then designated as belonging...
First of all apologies, I am a Cadence user, well for the SI tools anyway. Anyway a sister company uses pantheon as there layout tool, but I have been asked to...
John, Intercept has a separately licensed product that will allow you to write out of Pantheon to Cadence Allegro v13 or v14. In the past Intercept has done...
Greg, Thanks I have been told by Intercept that they are no longer able to supply the Cadence skill script due to some legal reasons. I'm not sure at what ...
Intercept has both interface tools available, they are licensed but work very well. Chuck ________________________________ From: InterceptUsers@yahoogroups.com...
Mike, Take a look at the files that have been uploaded to the InterceptUsers group on yahoo. You will find an IDF application there which I created. I'm not...
how successful is using the Specctra router with Pantheon? Anyone out there doing high speed rules with this router? do re-use blocks transfer to specctra?...
If you're asking about Mozaix, you can import image files in version 3.1_03A. The release note: Users of Mozaix may now add image files (.jpg, .gif, .bmp,...