I have 2 alternators for sale. They are both unused and are new as opposed to reconditioned. They are large, about twice the size of a car alternator. Fitted...
9382
Paul Hayes
mrphayes
Apr 13, 2011 12:50 pm
too many diesel cars on the road now about 51% as opposed to just 6% in the late 80's ________________________________ From: ron ohler <ohler_ron@...> ...
9383
Paul Hayes
mrphayes
Apr 13, 2011 12:56 pm
where are you located in uk? ________________________________ From: c695750 <henhurst@...> To: Lister_CSOG@yahoogroups.com Sent: Sat, 9 April, 2011...
9384
Paul Hayes
mrphayes
Apr 13, 2011 12:59 pm
I would like to remind everybody this chatroom for for Lister engines. I haven't read much about Listers so far....
9385
javickers
Apr 13, 2011 8:41 pm
I've seen four contributions from you, including this one, not a single one of which concerns Lister engines! I suggest that you should practice what you...
9386
Max Stemple
max_stemple
Apr 13, 2011 9:01 pm
Well, I dont even have a Lister and I'm here for some reason. I have about 4 or 5 China Diesels, A Kubota 3 cy. diesel generator, A 3 cy Mitbushi diesel ...
9387
Mick Hall
mickhall23...
Apr 13, 2011 9:35 pm
Heres a picture of a few of my Lister bits not exactly chat but a good picture of my latest Lister task. Took me a week to rebuild the 4.5 SOM head thats...
9388
briankk
briankk@...
Apr 13, 2011 10:10 pm
What Max said. I've got a couple of diesel Mercedes, a Cummins engined Dodge, and genset powered by an aircooled Deutz diesel. Â I've never seen a Lister...
9389
Ade
javickers
Apr 13, 2011 10:30 pm
At the moment, I own 3 Lister CS engines - 2 startomatic types, one complete/assembled/working, one in pieces & requiring a full restoration; and a 3.7hp...
9390
Michael Tarver
mikeyt_thatsme
Apr 13, 2011 10:45 pm
That Workmate sure looks small in that picture, Mick :) ... From: Lister_CSOG@yahoogroups.com [mailto:Lister_CSOG@yahoogroups.com] On Behalf Of Mick Hall Sent:...
9391
Dennis Thompson
dnthompwilson
Apr 13, 2011 11:14 pm
I have a Lister Model SL, mfg.d in 1961. I got it from my late marine machinist friend who in turn got it in Seattle from the place he worked. They had...
9392
Bob Stevens
bob_stevens12
Apr 13, 2011 11:58 pm
I have 3 lister SR3's,two are for parts one is running my home as a backup generator. My listers were removed from lighthouses here in Nova Scotia which have...
9393
ron ohler
reoair
Apr 14, 2011 12:11 am
Hi, Lucky slug... Too bad you're in the UK and not the USA. I'm still looking for a CS or clone. Best, Ron O ... From: Ade <javickers@...> Subject: Re:...
9394
clubsrdv8
Apr 21, 2011 9:54 am
Can anyone help with this please. Could you tell me how you work out how many BTUs or Kilowatts your wood burning boiler is able to produce. Many thanks Andy...
9395
bottleveg
Apr 21, 2011 5:04 pm
I've got a Lister 3kva SOM alternator that, I think, is the K type with the current transformer in the top box. If I set the engine speed so the alternator...
9396
Mick Hall
mickhall23...
Apr 21, 2011 8:07 pm
Bottleveg I think you are correct in your diagnosis And you should change your rectifier. It is very easy to exchange the old plate rectifier with a new modern...
9397
Dave
m_c_500
Apr 22, 2011 2:58 am
BTU output can be determined by measuring the water flow through the boiler, the temperature of the water going into the boiler and the temperature of the...
9398
Trevor
trevorkd1yt
Apr 22, 2011 12:06 pm
You can also get some sense of potential heat that may be available by considering how many BTUs is in a given quantity of wood (this will vary tremendously by...
9399
bottleveg
Apr 22, 2011 3:51 pm
... Mike, many thanks for taking the time to answer my question. I've fitted a new bridge rectifier but, sadly, to no avail. I have also purchased a plug in...
9400
Mick Hall
mickhall23...
Apr 22, 2011 5:49 pm
Bottleveg 210 volts is a little bit low the correct voltage should be 230 volts try adjusting this up a bit first by adjusting the main field rheostat. It...
9401
bottleveg
Apr 22, 2011 7:47 pm
... Ok I've adjusted it up to 230v and it's running at 50hz. The voltage does go up and down about 4v but no change in engine speed. If I apply 500 amps I get...
9402
nick booth
nickbooth56
Apr 22, 2011 9:05 pm
you also need to know the total surface area of internal heated surface area,including if fitted all tubes and thimbles ... From: clubsrdv8...
9403
Mick Hall
mickhall23...
Apr 22, 2011 11:38 pm
Bottleveg It looks to me like the choke(transformer) is not putting out enough voltage but unfortunately I do not know what voltage it should be. Maybe there...
9404
bottleveg
Apr 23, 2011 12:45 am
... Mick, thank you for your continued help. My suspicion is also turning towards the transformer. There is some `melted' residue at one end, which I presumed,...
9405
Mick Hall
mickhall23...
Apr 23, 2011 10:06 am
Bottleveg I think you are correct your unit is an in-betweeny and I have not come across a manual that deals with your specific type. The top box on your...
9406
David G. LeVine
sirdave144
Apr 23, 2011 1:22 pm
... Just to point out, 500 Amperes at 230 Volts is 115 KW. That is WAY over the generator rating. Could there be a typo here? I would expect the voltage to...
9408
bottleveg
Apr 23, 2011 1:36 pm
... Yes, My mistake. 500 watts....
9409
bottleveg
Apr 23, 2011 4:22 pm
Well, I've cleaned the terminals on the choke and resistor but still the same. I must have been taking a duff reading before, I've checked again in the...
9410
Mick Hall
mickhall23...
Apr 23, 2011 5:13 pm
Bottleveg It amazes me that people will pick up on small faults and not actually offer anything constructive to the problem in hand. I noticed the 500 amps and...
9411
Steve Spence
sspence65
Apr 23, 2011 6:26 pm
It's important to get the units right. Someone else may not know the difference. On Sat, 23 Apr 2011 13:01:26 -0400, Mick Hall <mickhall23@...> ... ...