i used default HVAC setting. ... From: jbf1119 <jbf1119@...> Subject: [VisualDOE] Re: Why is Default HVAC setting, energy use rise in winter in colder...
Hi Group, I have simulated the high-rise building with comparison two cases: + Case #1: The modeling use the standard glazing (clear double glasses in Visual...
Hi Hien, Please share the SHGC values for both the cases and the climate of the project. Regards, Rathnashree ________________________________ From: hien...
Hi group, Regarding to Visual DOE simulation, can we carry out the model of the daylight for the building by the output of the result ? Can we use the result...
Hi Hien, It is not possible to show LEED compliance for daylight in visual doe. Other softwares like ecotect, Radiance, Dialux, IES etc. has to be used. ...
Hi Rathnashree, Thank you so much, In the past, I have been used to the Dialux software to simulate the daylight modeling. But It is seem more complicated when...
<p>Hi Friend!<br>I refused to continue depending on other people this was my ticket to a free ride now I vacation four times a year you would excell at...
Hi, All Doe-2 programs has SS-R report generated. Is there any way to generate this report in Visual-Doe. Regards, Rathnashree [Non-text portions of this...
<p>whats up.<br>I had finally hit rock bottom this came at perfect timing for me this showed that money is power I had to share this with someone<br><a...
I would usually go to setup and run --> standard DOE-2 Reports, but I did not see SS-R there. What report is that anyways? I checked another DOE-2 based...
hi, everybody, i want to simulate how much energy could be saved by plant roof (green roof). Is there anyone ever used plant roof(green roof) function? does...
<p>Hi there...<br><br>I was tired of always having to borrow money I was able to regain my independence using this I knew that it was time to try something...
The only way you can simulate radiant cooling in visualdoe is to simulate the convective cooling of a system, either floor or panels as a two pipe fan coil...
Dear All, There are 4 places in which temperature for a zone can be input. Please let me know which temperature input Visual doe considers as the final indoor...
Numbers 1, 3 and 4 are what the system is sized for. Number 2 is what the system tries to control the space to. Generally, you will want to have the...
Hi Everyone, I have small query regarding outdoor fan calculation in VisualDOE. Recently for one of my LEED NCv2.2 project, USGBC reviewer has asked me to ...
Hi everyone, I am modeling a LEED Core & Shell building, and one of the requirements, per LEED Reference Guide Core & Shell Appendix 2 are "seperate meters for...
Dear Raval, You are correct that the result from the fan power calculation gives the power of the inddor fan only and not the outdoor fan.The power of the...
For modeling plant roof, generally what i do was i go to the construction option, in that i put the soil earth material over the RCC slab.The thickness of the...