3029
chemicalengineeringjobs-subscribe@yahoogroups.com ... http://groups.yahoo.com/group/chemicalengineeringjobs/ ... ...
wsc fgrt
tanjore_saran
Offline Send Email
Jul 3, 2004
1:30 pm
3030
hi everyone you can help me if u give information about history of hysys in chem eng thanks please send to my e_mail ( rafha83@...)...
rafhan:P
rafhan83
Offline Send Email
Jul 3, 2004
8:29 pm
3032
hello eveyone, i dont know if i can ask such questions in this group or not....but m just trying as i have no other option... i m gonna face some interviews in...
neha soni
neha_chemical
Offline Send Email
Jul 5, 2004
5:30 pm
3033
hi neha, i happened to be a chemengg.. which PSU are concerned here and which college are u frm? may be i can help nitin. neha soni <neha_chemical@...>...
c nitin
nitsfloyd
Offline Send Email
Jul 5, 2004
9:51 pm
3035
Hello group I have couple of questions for the expert of the group that I'd like to clarify. MATLAB I while ago I took a course on statistical identification,...
w l
bill_bill_20...
Offline Send Email
Jul 9, 2004
10:30 pm
3036
William, I believe that you have to consider API 521 for fire and other contingencies when you design any kind of safety valves. But i am sure there is one...
Amit Joshi
joshofindia
Offline Send Email
Jul 10, 2004
12:41 pm
3037
William, As Amit said, you have to use API 521 but API 520 is also recommended. Both API´s standard should go together when you are going to size these...
Carlos Antonio Diaz G...
cadiaz@...
Send Email
Jul 10, 2004
3:50 pm
3038
dear william we use here Api 520 for PSV and Rupture disck orifice sizing but use Api 521 for calculate Flowrate i remember that in api 521 recommend that for...
Farmand Masoomi
farmand_m
Offline Send Email
Jul 10, 2004
4:01 pm
3039
Hi Friends, Would you help me in locating distribution co-efficient of glycerine in coconut or palm kernel oil and water at various temperature? Thanks Banik ...
DR S Banik
sbanik2003
Offline Send Email
Jul 10, 2004
5:27 pm
3040
Hello all, I often need diffusion coefficients for finding Peclet numbers and such. Unfortunately, I have never found an extensive table of diffusion...
angrysamoan72
Offline Send Email
Jul 14, 2004
10:08 pm
3041
Hello my frind you can refer to perry hand book , i think u will find many diffusion coefficients for many compounds . Thank u, Maher ... ...
maher hamad
tdd300
Offline Send Email
Jul 15, 2004
1:54 am
3042
Dear Sir i have a problem more concerning to materials and fabrication. We are going to fabricate a urea distillation column for our client. The service is...
Nasiruddin Shaikh
nasir_genius
Offline Send Email
Jul 15, 2004
9:58 am
3043
Pls describe the temp and pressure at which these are to be operated and as well as the environment whether co2 rich or ammonia rich. Regards Khaleel ... From:...
Syed N. Khaleelullah
SKhaleel@...
Send Email
Jul 15, 2004
10:01 am
3044
Operating Temperature top = 0ºF Operating Temperature Bottom = 275ºF Operating Pressure = 50 psig Top section is CO2 rich and bottom section is NH3 rich. ...
Nasiruddin Shaikh
nasir_genius
Offline Send Email
Jul 15, 2004
10:14 am
3046
i want to know MATLAB could help to model distillation columns Carlos Antonio Diaz Guerra <cadiaz@...> wrote: William, As Amit said, you have...
Distillation Simulator
uha_2004
Offline Send Email
Jul 16, 2004
2:16 pm
3047
There is no such group (chemicalengineeringjobs) in Yahoo! groups. To the author, please email me why you have posted such info. Otherwise, your email address...
Allan S. Hugo
trekshop25
Offline Send Email
Jul 17, 2004
2:36 pm
3048
Greetings! Rafil may be right. It seems that this Spam emails come from automatic subscription to the groups. I think I may have to switch back to the setting...
Allan S. Hugo
trekshop25
Offline Send Email
Jul 17, 2004
2:48 pm
3050
Dear Friends, I have one question related to Aspen Plus Simulator. I have some results of Simulation of a crude distillation column with 12 stages. Now, to...
nm shah
mktmshah
Offline Send Email
Jul 21, 2004
7:48 pm
3051
Hi Nipen, Are you using Petrofrac? Then you should be able to select the refluxration on the Setup configuration window of Petrofrac. Please notice that you...
Administrador
charmandwisdom
Offline Send Email
Jul 22, 2004
11:03 pm
3052
dear sirs, greetings !! I am working on chemcad 5.2 devolped by chemstations . i had found this software to be great value but finding few difficulties. 1)...
ankush sood
ankush_sood123
Offline Send Email
Jul 24, 2004
2:57 pm
3053
If you are in India, you may want to contact Chemstations' agent, Axiom Engineers Pvt. Ltd. (Dr. C. V. Manian ) in Mumbai at 22 2686 2358 or 22 2686 1079 or...
Bharat Kamdar
bkamdar@...
Send Email
Jul 24, 2004
3:58 pm
3054
Dear Ankush, I work on Dynsim 3.3. In its model of heat exchanger it asks P and any of T, Vf, H. The pressure must be specified. The simulator is capable of...
Pradeep Gupta
pradeep172001
Offline Send Email
Aug 5, 2004
4:46 am
3055
Hi, What are the variables usually used in conventional distillation columns for 4x4 control? Thanking in advance. Thanks Arnab...
arnabchakrabarty
arnabchakrab...
Offline Send Email
Aug 10, 2004
6:39 am
3056
Dear Arnab, if we want to study the control of entire distillation set up, it is going to be 5x5 control problem. the controlled variables being 1. Column...
N.V.S.N.MURTHY KONDA
murthy_feb11
Offline Send Email
Aug 10, 2004
7:02 am
3057
Hello Yes this is the basic model for Microbial Growth. Though for some cases there would also be a growth inhibitor variable added in this model. I am at ...
Anshuman Das
anshu_das@...
Send Email
Aug 11, 2004
11:33 am
3058
hello folks! i am looking for (kind of) career guidance. i am chemical engineer working in FACT cochin. i am in process control side (operation). i am trying...
satis babu
satisb
Offline Send Email
Aug 13, 2004
3:57 pm
3059
hi, SAP is the most sought after course nowadays. Or that's what everyone talks abt. but u have to analyse the pros and cons before jumping...
Alwin
jva_gem
Offline Send Email
Aug 15, 2004
12:58 pm
3060
Hello, Does anyone have any recommendations on using software for doing a pressure drop calculations in a loop. We have a Dowtherms Thermic fluid system being...
Yogesh Diwan
yogesh_diwan
Online Now Send Email
Aug 16, 2004
6:52 pm
3061
hi dude, if u can manage an MBA from a good institute, nothing like it. S/W also pays well....but most of the jobs are boring..and they make u work like a...
c nitin
nitsfloyd
Offline Send Email
Aug 18, 2004
9:20 pm
3062
  hi all i m facing one problem regarding job function i have just joined detail engineering consultancy firm now the company is giving me choice for choosing...
PRS
i_m_i_n_d_i_a_n
Offline Send Email
Aug 19, 2004
2:28 pm
Messages 3029 - 3062 of 4721   Oldest  |  < Older  |  Newer >  |  Newest