1630
What's your optimized conditions for organophosphorous pesticide with megabore column (JW DB5 0.53 mm i.D and 15 m length )and this specific instrument CPG...
noziraf
Offline Send Email
Jul 1, 2003
9:35 am
1631
hi guys I'm a french student in bachelor of chemical engineering and I carry out some analysis on amino acids I have to identify two amino acids, glycine and...
thefrenchwitch
Offline Send Email
Jul 3, 2003
5:22 pm
1632
Hi, I hope someone can help me with this problem. I've been trying to set up a method to analyse PAH's on HPLC. Now that ain't the problem really, I've got a...
jevdende
Offline Send Email
Jul 3, 2003
5:22 pm
1633
Just wondering if anybody would know LC conferences in Japan this year ??...
emailkong
Offline Send Email
Jul 8, 2003
5:53 pm
1634
Dear members of this list, I need information in order to get Internet address to buy scientific book apart from AMAZON. I need an used book which was...
DRDN
tequila2@...
Send Email
Jul 9, 2003
9:11 am
1635
Hi, I have two questions: 1. Are you trying to find low levels of PCBs? 2. what are your chromatographic conditions. mike ... From: jevdende...
The Shifflet's
shiffty@...
Send Email
Jul 10, 2003
9:56 am
1636
Hi, Could you elaborate on the HPLC system. I am curious about the problems with a blank injection of solvents. Thanks, mike ... From: nfitzgerald...
The Shifflet's
shiffty@...
Send Email
Jul 10, 2003
10:02 am
1637
Dear all, I am new to HPLC. I did the worst thing with the brand new HPLC column (Bondapak C18) by forgot to check the amount of the mobile phase and it all...
kimmikar
Offline Send Email
Jul 11, 2003
6:07 pm
1638
Dear Kimmikar, Disconnect the column from the detector end and raise the column so that the disconnected end is higher than the injector side. Flow 100%...
Tony Herlt
herlt@...
Send Email
Jul 11, 2003
11:39 pm
1639
Dear Kimmikar A good way to get rid of the air bubbles is to wash your column with 100% organic mobile phase. If there is a inorganic salt in the mobile phase...
Rodrigo Martins
rodrigodiasm...
Offline Send Email
Jul 12, 2003
9:32 am
1640
Hi everyone on the Chrom-L group! My name is Bob Albrecht. I am formerly of LC Resources and Biotage, Inc. My specialty is software and instrumentation for...
Bob Albrecht
blondtraveler
Offline Send Email
Jul 15, 2003
7:38 am
1641
Dear all, I am doing a quantitative analysis of Vitamin E and Vitamin E acetate. The retention time of them in ACN:Water (96:4) are 13 and 16 minutes. I would...
Hansa M.
kimmikar
Offline Send Email
Jul 18, 2003
8:11 am
1642
5 Suggestions: 1. Add more acetonitrile or switch to a different solvent. 2. Buy a shorter or less retentive column 3. Raise the flow rate 4. Raise the column...
juddman@...
chrstopherjudd
Offline Send Email
Jul 18, 2003
1:52 pm
1643
Dear colleagues, we are looking into replacing our current TEA (Thermal Energy Analyzer) detector. I am aware that there are very limited sources for this type...
Diego Zurbriggen
Diego_Zurbriggen@...
Send Email
Jul 25, 2003
6:26 pm
1644
We have noticed something curious about our DAD and don't know whether this is normal or we are programming it incorrectly. We choose the baseline, apex and...
jeanire2001
Offline Send Email
Jul 25, 2003
6:26 pm
1645
Dear chrom-L members, I am searching for papers and sources of informaation on modification to chromatography theory to account for permanent adsorption of...
dan_brett2003
Offline Send Email
Jul 25, 2003
6:26 pm
1646
Hi everybody I would like to know if anybody knows how to measure the area of the peaks from the chromatograms and mass spectra. Thanks for any replies, Lilia...
lbenderm
Offline Send Email
Jul 25, 2003
6:29 pm
1647
Dear All We have some money to purchase some ion chromatography kit (both anion and cation with autosamplers) and have been in contact with Dionex and Metrohm....
Biomaterials
ugez323
Offline Send Email
Jul 28, 2003
9:58 am
1648
Dear ALL I am planning to analyse some endogenous compounds in human plasma, would anybody know how to prepare plasma blank (without endogenous compounds) ? ...
Kong M LI
emailkong
Offline Send Email
Jul 29, 2003
5:05 pm
1649
We have recently been donated an perkin elmer liquid chromatograph with this modules: 1. Pe nelson 900 series interface 2. Pe nelson 600 series link 3. uv /vis...
Edgardo Monasterios
emonasterios
Offline Send Email
Aug 1, 2003
9:13 am
1650
At 10:08 28/07/03 +0100, you wrote: Hi Jonathan I have done ion Chromatography using Dionex Instrument and found to be really good both for anion and cation....
Emmanuel Samuel
emmanuel.samuel@...
Send Email
Aug 1, 2003
12:56 pm
1651
Dear all Can anyone tell me about a "standardized procedure for the extraction and quantifictaion of soyasaponins in soybeans and foods by using High...
Molamma Prabhakaran
molsb
Offline Send Email
Aug 2, 2003
12:10 pm
1652
My institute plans to buy a Maldi-Tof mass spectrometer, to be used in research work involving proteomics and drug development. Can any member of the group...
rajneeshanand
Offline Send Email
Aug 5, 2003
9:04 am
1653
Dear All, Can someone advise me on how to improve yields when purifying natural products via HPLC/UV? Any tips or even a listing of the factors involved would...
baovmai
Offline Send Email
Aug 6, 2003
6:46 pm
1654
If you are trying to purify a single component from a natural product, then resolution is everything. Extending the gradient time (shallower gradient) until...
Bob Albrecht
blondtraveler
Offline Send Email
Aug 7, 2003
10:35 am
1655
Dear all Can anyone tell me "if a mobile phase of 0.1% TFA in water and 0.1% TFA in Acetonitrile can harm a C-18 ODS column?"I require these solvents to run...
Molamma Prabhakaran
molsb
Offline Send Email
Aug 11, 2003
10:04 pm
1656
Dear all: The retention time of a standard is changeble when i use HPLC-FLD.For example:the same standard's retention time is not stable(the first injection is...
 
g_huili
Offline Send Email
Aug 11, 2003
10:04 pm
1657
Normal use of 0.1 % TFA mobile phases should not harm your HPLC systems. I would not store the column or the HPLC system with the 0.1 % TFA. Prior to storage...
The Shifflet's
shiffty@...
Send Email
Aug 12, 2003
2:34 am
1658
Hi, How long are you conditioning your column. It would seem that the column is not completely conditioned prior to your first injection. Depending on your...
The Shifflet's
shiffty@...
Send Email
Aug 12, 2003
2:55 am
1659
Are you injecting some blanks before your standards? As The Shifflet's said, it seems that your column is not well conditioned, maybe the solvent was finished ...
Valentina Lonzarich
valentina13@...
Send Email
Aug 13, 2003
8:11 am