Hello friends I am trying to do some studies on the presence of Citricidal (diphenol hydroxybenzene) on GrapeFruit Extracts, Lemon and Citrus extracts, Olive...
Hi, I have some other suggestions that may be of value. 1. Is the injection solvent high in organic composition? If so you could modify it to contain more...
the Shifflets
shiffty@...
Sep 8, 2004 12:52 am
1953
Dear all, Can anybody help me with the analytical HPLC method in determining the purity of Gabapentin ? Thanking you all in anticipation, From, Mr. Kiran Desai...
Has anyone analysis zoledronic acid using HPLC before?? I have found one paper on this drug which is published on the Journal of Pharmaceutical and Biomedical...
Good day group members. I am looking for an HPLC/GPC/GC or normal chemistry method for the quantetive determination of Keropur(r) (active component is ...
Groenewald, Conrad (CW)
conrad.groenewald@...
Sep 10, 2004 10:23 am
1957
The NOAA/National Ocean Service/ Center for Coastal Environmental Health and Biomolecular Research in Charleston, SC (CCEHBR) has two contract positions open...
Good Morning group members: I wonder if some one in the group has any experience in the analysis of a product containing Diclofenac K, plus Vitamins B1-B6 and...
Hallo, does someone analyze AA composition by HPLC afer derivatisation with OPA and FMOC? Which is the most useful column? Can a C18 column work well? Thank...
Dear Anybody, We are planning to use GC 14BPTF (Shimadzu) for the analysis of ethanol in water solution and ethanol in air mixtures using FID and TCD. Please...
Ver, Generally, water + flame = no flame. But it is possible. Try DB type column, narrow bore, 10-15 meters, split, and no makeup gas in detector. I was...
To the drylab question from: "jlpryuen" <00000663@...> Try Molnar Institut in Berlin. They are the best in this field! ...
Dr. Ohmacht Robert
robert.ohmacht@...
Sep 20, 2004 6:01 am
1965
Dear All, I am interested in HPLC quantitation method of determination of solanesol in tobacco leaves. Please let me know the reverse phase method for this...
Dear all, I am a member of this and many other newsgroups, and must admit that on this one I mostly lurk, rather than play an active part in debate and...
Hi Peter, You make some very good points and obviously it's a bit annoying for people to feel like they're doing someone else's homework! I don't think people...
Hi Jo, ... Sorry, but could not agree, I'm a member of much larger e-forums and the chatting there is much more intense. I'm observing this group for a long...
Hi All, I m looking to purchase Module Assy (PN # MOD-2003)- for Hewlett Packard Micro GC. Is there anybody can help, where I can get the replacement module ? ...
Hi, I have never used this type of instrument but I checked out their web page and it looks good on paper. What concentrations of ethanol will you be ...
the Shifflets
shiffty@...
Sep 25, 2004 7:32 pm
1972
I have some stains(silver nitrate) in my hands? how to remove them? thanks!...
If the silver nitrate stains became already black, the silver-nitrate has been reduced to metallic silver (lapis infernalis!) and you can do nothing. In some...
Dr. Ohmacht Robert
robert.ohmacht@...
Sep 27, 2004 12:54 pm
1975
Dear Fellow Chromatographers, recently we substituted in our GC autoinjectors 5 µL syringes for 10 µL syringes, since they allow the injection of volumes <...
matthias.kummer@...
Oct 1, 2004 12:45 pm
1976
We had the same problem with 5 µl GC syringes in Thermo GC autosampler, and we work too with exane, water, chloroform, etc. and derivatizing reagents. It...
Can anybody tell me if there is any problem with determining the UV response factor (using linearity slopes) of a compound relative to another by performing...
Hi All, I have chromatographic data coming out from an HPLC column. The profiles are an overlap of Gaussian curves and each peak represents a protein of a...
Hi Parag, ... You can do the job in an Excel spreadsheet using solver option, unless you have many data points (practically more then 30000, 65536 is the...
Karol Pilorz
PILORZ@...
Oct 4, 2004 10:44 am
1980
Microcal Origin performs deconvolution much more easily than Excel, it have standard equations expecially for chromatography, like the EMG. Good luck Fabiano ...