Search the web
Sign In
New User? Sign Up
chrom-L · Chromatography, SPE, LC/MS, HPLC, GC/MS
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Want your group to be featured on the Yahoo! Groups website? Add a group photo to Flickr.

Best of Y! Groups

   Check them out and nominate your group.
Having problems with message search? Fill out this form to ensure your group is one of the first to be migrated to the new message search system.

Messages

  Messages Help
Advanced
Messages 2275 - 2304 of 2316   Oldest  |  < Older  |  Newer >  |  Newest
Messages: Simplify | Expand   (Group by Topic) Author Sort by Date ^
2275
I am trying to analyze zoledronate in serum by derivatizing it to its ethyl ester and then analyzing by GC-MS,however,the internal standard used in the article...
jr00729
Offline Send Email
Jul 7, 2006
11:28 am
2276
These links will have the information you need. 600E pump: http://www.waters.com/WatersDivision/SiteSearch/AppLibDetails.asp?LibNum=720000751EN 490E detector: ...
Walter Holberg
wcholberg
Offline Send Email
Jul 7, 2006
11:30 am
2277
Dear Friends, I am using an old Varian 3400 GC (with FID detector; there is no slip injector). I am injecting 1 ul of sample (in pentane/hexane). It is giving...
Vivek Upadhyay
vivek_upadhyay
Offline Send Email
Jul 7, 2006
11:47 am
2278
If your samples are soluble in it, you can try carbon disulfide, CS2. The FID is almost 'blind' to this solvent, keeping a low steady baseline. You will need...
Lazarski, Peter M.
usngrid
Offline Send Email
Jul 7, 2006
11:58 am
2279
Dear Members, I wanted to fill SS column with C 18 material.Does any one can help me as how to fill the column or give me a clean procudure guidelines,The...
Rajesh Galgalikar
rajesh@...
Send Email
Jul 7, 2006
12:23 pm
2280
... You didn't say, but I'll assume you're using a common capillary column. Check your split ratio. It sounds like you're running a splitless injection, so...
David Bostwick
david.bostwick@...
Send Email
Jul 7, 2006
2:38 pm
2281
I want to find k and alpha for poly(ethylen)glycole adipate in chlorophorm to make some GPC measurements. Can somebody help me? A.T ... Yahoo! Messenger with...
Taranu Anca
taranu_a
Offline Send Email
Jul 7, 2006
4:13 pm
2282
Dear members of this forum, Thanks for all owing to many members gave the information I need in order to finish my work. Thanks as always again, Diego ... ...
Diego Delmonte
tequila2@...
Send Email
Jul 19, 2006
1:25 am
2283
Dear colleagues, I'm needing some help again! I need 2 articles that I don't have access. Can somebody send them to me? 1: Lapolla A, Flamini R, Dalla...
Guilherme Vannucchi P...
gv_portari
Offline Send Email
Sep 5, 2006
2:02 am
2284
Anyone have a good method for caffeine (or other markers of human sewage) in river water? Preferrably SPE HPLC but GCMS could work also. The more detailed...
nfitzgerald
Offline Send Email
Oct 18, 2006
5:27 pm
2285
Hi, we are currently testing a batch of alpha terpineole (FCC). The requirement for the assay is: not less than 96.0% (sum of alpha-, (E)-beta-, (Z)-beta-,...
Thomas Vater
thomas.vater@...
Send Email
Dec 2, 2006
9:47 am
2286
11th December 2006 Dear colleagues, I would like a copy of the following article if any of you have it in your research library: Parpinello, Giuseppina Paola;...
Tony_Herlt
herlt@...
Send Email
Dec 11, 2006
1:07 am
2287
Dear members of this list, I would appreciate if anyone help me in order to get two articles which is very helpfull for me in order to improve my work with ...
tequila2@...
Send Email
Dec 15, 2006
11:35 am
2288
Senior Scientist/Group Leader - Analytical Development A great company in Tarrytown, NY is seeking a Senior Scientist/Group Leader-Analytical Development....
Khristine Anderson
michaelwilmarth
Offline Send Email
Feb 9, 2007
10:56 am
2289
Hello, I'm working on an HPLC, Hewlett Packard 1050. I'm not being able to detect any peak, even though I can see that the detector is reading an absorbance...
zalghoul
Offline Send Email
Feb 23, 2007
9:56 am
2290
Manager, Process Development - San Diego, CA A client of ours in San Diego, CA is seeking a Manager, Process Development. They are a specialty biotechnology...
Khristine Anderson
michaelwilmarth
Offline Send Email
Feb 23, 2007
9:57 am
2291
Dear members of the list, i have been appointed to a new laboratory and i am expected to learn how to detect mycotoxins in food and feed materials. firstly i...
rindkursataktas
Offline Send Email
Feb 23, 2007
9:57 am
2292
Senior Analytical Scientist - Torrance, CA I am assisting to recruit a Sr Analytical Scientist for a great company in Torrance, CA. Would you be interested in...
Khristine Anderson
michaelwilmarth
Offline Send Email
Feb 23, 2007
9:57 am
2293
dear members of the list, i am looking for a training program for mycotoxin analysis by using biosensors. would someone lead me an addres to solve my problem? ...
rind
rindkursataktas
Offline Send Email
Feb 23, 2007
9:57 am
2294
I'm running some HPLC soybeans extracts with ETOH 70% with acetic acid 0,1%, but I got no Genistein peak, although I got a peak at gradient run at 37 minutes...
chang
changuinho2000
Offline Send Email
Feb 23, 2007
10:01 am
2295
Hi, Is the system conected to an integrator or to a chromatography station? In either case I would first check to see if the cables are connected tightly. Do...
the shifflet's
shiffty@...
Send Email
Feb 24, 2007
12:44 pm
2296
26th February 2006 Dear colleagues, I am trying to obtain the following article: Title: Analysis of peptides at low levels using a chromatography system...
Tony_Herlt
herlt@...
Send Email
Feb 25, 2007
10:18 pm
2297
I need the components of a simple method to determine Vitamine 25 OH D3 in HPLC.The method is as follow: Sample preparation Mix briefly 500 µl serum/plasma...
Gianfranco Bruno
gbruno_2000
Offline Send Email
Feb 26, 2007
5:15 pm
2298
We use a method to determine plasma catecholamine in HPLC.Prior the plasma is precipitated with a reactive A.Then exctrated with a resin mixed to...
Gianfranco Bruno
gbruno_2000
Offline Send Email
Mar 25, 2007
8:52 pm
2299
Dear Friends Could you anyone suggest us for doing Chef test and swap test in water,meat and fish. Charm sciences inc is making such instrument. If you know...
j_sadikali
Offline Send Email
Apr 13, 2007
3:40 pm
2300
We have a HP5890 GC-FID and a Varian 3400 GC-ECD. Both currently have integrators. I'd like to replace both integrators with one computer. We never use both...
nfitzgerald
Offline Send Email
May 2, 2007
8:13 pm
2301
3rd May 2007 There is chromatography data system software called Delta 5.5 that would probably work well with your GC instruments and is competitively priced. ...
Tony_Herlt
herlt@...
Send Email
May 2, 2007
11:29 pm
2302
Problem: We are consistently seeing peak(s) around 14-18 amu over 40 abundance in the autotune spectra on an Agilent 5973 MSD connected to an Agilent 6890 GC....
creakinator
Offline Send Email
Jul 18, 2007
8:47 pm
2303
Why a C18 Column with a mobile phase with ion pairing conditions on more time than a C18 with a mobile phase without ion pairing? thank you Gianfranco ...
Gianfranco Bruno
gbruno_2000
Offline Send Email
Sep 20, 2007
4:11 pm
2304
Please I need this article or similar: Thank you Gianfranco AU: N. Lammers, J. Zeeman, G. J. De Jong TI: Effect of some parameters on the liquid...
Gianfranco Bruno
gbruno_2000
Offline Send Email
Oct 1, 2007
5:14 pm
Messages 2275 - 2304 of 2316   Oldest  |  < Older  |  Newer >  |  Newest
Advanced
Add to My Yahoo!      XML What's This?

Copyright © 2009 Yahoo! Inc. All rights reserved.
Privacy Policy - Terms of Service - Guidelines - Help