Dear COMIS users,
An increasing number of users contact me about numerical
problems running coupled simulations (using COMIS as a TYPE in TRNSYS).
It appears that a good deal of these problems is
simply due to an unfortunate default value used in the graphical environment of
COMIS: the default solver used for COMIS by Simulation Studio is solver 1 (
For coupled projects, however, solver 6 (trust region
line search) is more appropriate.
So if you encounter problems running coupled
projects, you should just try to
-
change the solver in the
COMIS (*.cpf) project (Assembly/Control cards/Control tab, select “
-
re-write the COMIS input
file (.cif) from the COMIS project (Calculate/Create Input file)
-
Re-run the TRNSYS (.tpf)
project
Werner Keilholz
TIDS / IIL / Ingénieur
Centre Scientifique et
Technique du Bâtiment
84 avenue Jean Jaurès - Champs-sur-Marne -
Tél : 04
Fax :
Port :
Évitez d’imprimer vos
emails inutilement. Respectez l’environnement
Ce message et toutes les pièces
jointes sont confidentiels et exclusifs pour le destinataire du message.
N'importe quelle autre distribution, utilisation ou reproduction est non
autorisée et interdite. Si vous receviez ce message par erreur, informez svp
l'expéditeur immédiatement et supprimez le message de votre système.
This
message and any attachments are confidential, for the exclusive use of the
addressee and may be legally privileged. Any other distribution, use or
reproduction is unauthorised and prohibited. If you received this message in
error, please notify the sender immediately and delete the message from your
system.
************************************************************************************
This footnote confirms that this email message has been scanned by
PineApp Mail-SeCure for the presence of malicious code, vandals computer viruses.
************************************************************************************