117
Hello, everybody! I have encountered problemes in running comis applications: I receive a message that requires a comis set file; what is this set file? Thank...
indutza
Offline Send Email
Mar 7, 2002
10:31 am
118
Hi Ilnica The SET file is an optional file that contains predefined settings for certain options in COMIS. COMIS can run quite happily without the SET file, it...
Peter G. Schild
peter_g_schild
Offline Send Email
Mar 7, 2002
10:49 am
119
I'm sorry to boder you like this, but where can I find examples for comis3.1 with iisibat interface? I mean examples with the description of the building ...
ilinca nastase
indutza
Offline Send Email
Mar 7, 2002
1:36 pm
120
Dear Ilnica A couple of example input files are bundled together with "COMISexcel" which you can download from the COMIS YahooGroup site regards, Peter ... ...
Peter G. Schild
peter_g_schild
Offline Send Email
Mar 7, 2002
2:07 pm
121
the message I'm receveing is the following: forrt1:severe<29>:file not found, unit13, file C:\icomis\Appli\Root\Simul\COMIS.SET ... ...
ilinca nastase
indutza
Offline Send Email
Mar 7, 2002
3:50 pm
122
hi ilinca, as far as i remember we had a similar problem in the test version of comis 3.1 with iisibat. in some installations simulations can be run under...
Anne Haas
annehaas_empa
Offline Send Email
Mar 7, 2002
5:24 pm
123
I think in the freeware version (COMIS 3.0) the COMIS.SET file was actually needed. If I remember it right, you will find one in the \icomis\msdos directory....
wkeilholz
Offline Send Email
Mar 7, 2002
6:34 pm
124
In IISiBat, they are in the Library Manager (Libman icon). If you don't want to use IISiBat, you find the COMIS Input Files (CIF) under \icomis\comis\Examples\...
wkeilholz
Offline Send Email
Mar 7, 2002
11:47 pm
125
Thank you all very much, I put a copy of comis.set file in my simulation directory and it worked! Now the simulations run properly. Thank you very much. Ilinca...
indutza
Offline Send Email
Mar 8, 2002
1:57 pm
126
Dear friends I can't make a simple link with a duct. There are always error messages. I simplify the problem to only a duct lied to an external node and to a ...
mansouri
zohramansouri
Offline Send Email
Mar 18, 2002
12:54 pm
127
Hello, this error means that the element 'crack_2' is not defined as a LINK, although an output is requested for it. To see what the actual problem is, we...
Werner Keilholz
wkeilholz
Offline Send Email
Mar 18, 2002
1:38 pm
128
Thank you for your rapid answer. Unfortunately to continue my project it is essentiel that I resolve this problem. I work with iisibat. Effectively I always...
mansouri
zohramansouri
Offline Send Email
Mar 18, 2002
2:51 pm
129
As I had suspected, the crack_2 objects are no longer in the project - they have been deleted. To solve the problem, open the Output window, save it and re-run...
Werner Keilholz
wkeilholz
Offline Send Email
Mar 18, 2002
2:59 pm
130
Dear All, I have Comis 3.0 and Trnsys15 version and I am trying to couple them following the instructions written in the read text file in the service pack,...
katerina Niachou
aniachou@...
Send Email
Mar 19, 2002
12:34 pm
131
Hello Niachou Katerina Your compiler does not find the include files. You have to put the *.FOR files from the service pack into the directory where all other...
Andreas Weber
andreas_webe...
Offline Send Email
Mar 19, 2002
1:06 pm
132
Dear Mr Weber, I appreciate a lot your advice. I will try it and I will answer you immediately. With Kind Regards Katerina Niachou Katerina University of...
katerina Niachou
aniachou@...
Send Email
Mar 19, 2002
2:58 pm
133
Dear friends, I made a simulation and I had this error message despite of that I had the results of my simulation. The maximum number of iteration steps has...
mansouri
zohramansouri
Offline Send Email
Mar 21, 2002
11:38 am
134
In IISiBat, this is done in the 'global cards' window, accessed by the 'General Information Tool', as described on page 34 of the IISiBat manual: Click on the...
Werner Keilholz
wkeilholz
Offline Send Email
Mar 21, 2002
1:28 pm
135
Dear friends, [Image] Faithfully yours Yasmine MANSOURI Laboratoire CERMA - UMR CNRS 1563 - École d'Architecture de Nantes Rue Massenet BP 81931 44319 Nantes...
mansouri
zohramansouri
Offline Send Email
Mar 29, 2002
10:39 am
136
Dear friends, Iam so sorry for my previous e-mail, which was not clear. I realize that the Cs coefficient has an important role in the airflow modeling in...
mansouri
zohramansouri
Offline Send Email
Apr 3, 2002
8:27 am
137
Dear Yasmine There are two approaches to specifying Cs coefficients. 1) Calculate all the crack lengths in the building by summing up all the wall junction...
Peter G. Schild
peter_g_schild
Offline Send Email
Apr 3, 2002
10:06 am
138
Hi Jan, Cs is similar to, but not exactly the same as, Cd (discharge coefficient). There are two types of Cs, for describing (i) mass flow rate or (ii)...
Peter G. Schild
peter_g_schild
Offline Send Email
Apr 3, 2002
4:37 pm
139
It seems to me that your problem arises from trying to compare the duct relation and the orifice equation too closely. Keep in mind that rewriting the duct...
David M. Lorenzetti
DMLorenzetti@...
Send Email
Apr 3, 2002
11:16 pm
140
Dear colleges, Concerning the above roof level wind pressure coefficients, Lugtenberg A. reported in #NO 1302 Air flow around buildings - pressure measurements...
janmaeyens
Offline Send Email
Apr 4, 2002
9:04 am
141
Jan, in the Lugtenburg study the wind pressure coefficients above the roof increase with the height due to the increase of wind velocity with the height (Zo...
Knoll, Bas
basknoll
Offline Send Email
Apr 4, 2002
10:56 am
142
Dear all I just want to clarify some points in my last mail to Jan (repeated below): (i) The generalized crack flow equations I cited do not apply for straight...
Peter G. Schild
peter_g_schild
Offline Send Email
Apr 5, 2002
11:01 am
143
Hello, I am new to this and am trying to locate a weather data file to imput into the Energy Plus program. Would you be able to point me in the right...
megadomeus
Offline Send Email
Apr 12, 2002
3:49 pm
144
Dear All, I have Comis 3.1 and Trnsys15 version and I am trying to couple them following the instructions written in the read text file in the service pack,...
bzeghondy
Offline Send Email
Apr 30, 2002
4:16 pm
145
The comis-trnsys service pack on the cstb web server is only for the freeware version comis 3.0. If you purchased the version 3.1, you have the correct comis...
Andreas Weber
andreas_webe...
Offline Send Email
May 2, 2002
12:22 pm
146
Helo I followed the instructions that you gave me and now I have this new problem. Deleting intermediate files and output files for project 'test3 - Win32...
barbar zeghondy
bzeghondy
Offline Send Email
May 2, 2002
4:57 pm
Messages 117 - 146 of 858   Oldest  |  < Older  |  Newer >  |  Newest
Advanced
Add to My Yahoo!      XML What's This?

Copyright © 2009 Yahoo! Inc. All rights reserved.
Privacy Policy - Terms of Service - Guidelines - Help