620
Hello group Under &-WI, what is the value for Cs for open doors? Cs is defined as flow coefficient for close windows per m crack length. If the door or window...
Lisa
china4ever2003
Offline Send Email
Oct 16, 2006
9:23 pm
621
... The Cs value (in the second row of the *W block) describes the window/door leakage when it is closed. As the window/door opens, the airflow is determined...
David M. Lorenzetti
DMLorenzetti@...
Send Email
Oct 16, 2006
10:00 pm
622
Thank you, your response was of great help. I am modeling a type 1 WI so won't need to know how the opening fraction is used here. Thanks again for the quick...
Lisa
china4ever2003
Offline Send Email
Oct 17, 2006
1:32 pm
626
Dear sir I have download the software of COMIS 3.0 with IISiBat from http://evl.cstb.fr/francais/projets/IISiBat/COMIS/confcom.htm. When I run the software, it...
kwanghvacr
Offline Send Email
Oct 25, 2006
7:32 am
627
As far as I know, this version does not run on Windows XP. I guess that might be the problem. Nicolas Heijmans Belgian Building Research Institute (CSTC - WTCB...
Nicolas Heijmans
heijmansnicolas
Offline Send Email
Oct 26, 2006
9:06 am
629
COMIS 3.1 does run on Windows XP, as well as its graphical interface. But you should not use the old (outdated link) to access it. The right link is ...
keilholz, werner
wkeilholz
Offline Send Email
Oct 30, 2006
8:43 am
631
dear Werner and Nicolas Heijmans Thank you very much for your responds. I have download the COMIS 3.2 from http://software.cstb.fr/soft/present.asp?langue=us....
kwanghvacr
Offline Send Email
Oct 31, 2006
2:33 am
632
The older versions of COMIS also run on XP, as far as the kernel is concerned. The graphical User Interface, however, does not run on XP. You could try to use...
keilholz, werner
wkeilholz
Offline Send Email
Oct 31, 2006
8:37 am
633
Hi there: I found this mistake message: the pollutant name co2 in schedule Qco2 matches none of the pollutants. Correct the input at &-NET-ZONE or &-POL-DES...
cainabj
Offline Send Email
Oct 31, 2006
8:41 am
635
Dear all: I read about the content on histograms in the Comis user guide, but I wonder how I can difine the histograms in simulation studio? Thanks a lot!...
cainabj
Offline Send Email
Nov 1, 2006
6:01 am
636
Dear all: I read about the content on histograms in the Comis user guide, but I wonder how I can difine the histograms in simulation studio? Thanks a lot!...
cainabj
Offline Send Email
Nov 1, 2006
6:02 am
637
In the Studio, you define histograms in the 'Control Cards' (Control Card button or 'Assembly/Control Cards...' menu): Go to the Schedules/Layers/Occupants...
keilholz, werner
wkeilholz
Offline Send Email
Nov 2, 2006
9:18 am
640
Dear COMIS group member I'm Fujikawa at Yoshino lab of Tohoku University Japan. I have a question about contaminant calculation. Sorry for my poor English. My...
Mitsutoshi Fujikawa
us.light_wis03
Offline Send Email
Nov 8, 2006
7:34 am
641
Hello, Mitsutoshi, You can try our model COwZ (COMIS with sub-zones). There are no limits for the zone number. You can also get details of airflows,...
Zhengen Ren
zren401
Offline Send Email
Nov 8, 2006
9:47 am
644
Dear COMIS users It is written on the user's guide that some couple of data(pressure and airflow rate) can be used as the performance of a fan. And it seems...
skcomis
Offline Send Email
Nov 17, 2006
3:20 am
646
Hello, I don 't know TRNFLOW, but if its like in COMIS, fans are defined by a fan curve. There are two ways of doing this, either by giving data pairs or ...
keilholz, werner
wkeilholz
Offline Send Email
Nov 17, 2006
3:28 pm
647
... Typically in COMIS the pressure that drives flow through a link is the hydrostatic pressure difference. The exception is when the link connects to an...
David M. Lorenzetti
DMLorenzetti@...
Send Email
Nov 17, 2006
5:18 pm
650
Hello, Does Comis adjust the Cp-values at an open window automatic? Or does it still use the values that are given as input? Thanks....
m0323559
Offline Send Email
Nov 25, 2006
5:39 pm
652
I believe that COMIS reads in whatever direction dependent values of Cp are entered for a given opening. Kind regards, David ... ...
David Bradley
tesstrnsys
Offline Send Email
Nov 27, 2006
4:33 pm
655
Dear all The different positions of a facade have the different Cp values, but in the &-CP-VALUes, it is only need to input one Cp value for a whole facade...
kwanghvacr
Offline Send Email
Dec 10, 2006
8:26 am
656
Dear Wangke, ... I usually get CPCALC (or the program that I prefer: CpGenerator) to calculate Cp values for various places on the facade to see the extent of ...
David Bradley
tesstrnsys
Offline Send Email
Dec 11, 2006
4:08 pm
663
Hello everyone, Does anyone know what the maximum number of types of cracks are allowed in COMIS, if there even is a limit? Thanks! Lisa...
Lisa
china4ever2003
Offline Send Email
Jan 11, 2007
9:31 pm
664
... The answer here is based on COMIS 3.0, the last public-domain version of the program. I imagine the current version of the code has the same basic design,...
David M. Lorenzetti
DMLorenzetti@...
Send Email
Jan 11, 2007
10:27 pm
680
Hello, I see that COMIS has the capability to specify ducts that connect zones. However, are these ducts associated with an air handling unit that can...
Lisa
china4ever2003
Offline Send Email
Feb 20, 2007
3:48 pm
681
Dear Lisa Yes, COMIS can model ductwork. There are a number of built-in ductwork components, such as bends and T-sections, for which COMIS calculates pressure...
Peter G. Schild
peter_g_schild
Offline Send Email
Feb 21, 2007
11:50 am
682
Peter, Thanks so much for the information! It is of great help. Lisa ... and ... long...
Lisa
china4ever2003
Offline Send Email
Feb 21, 2007
1:21 pm
691
Dear all: I have a problem on coupling TRNSYS16 & COMIS 3.2 with Type 157. Three notices and three error messages were found acoording to project log, as...
khrgen
Offline Send Email
Mar 12, 2007
6:49 am
693
Read the readme.txt file in .\comis32\Binary\Trnsys16 of your COMIS 3.2 installation to see which dll you have to copy into your TRNSYS directories. ...
Andreas Weber
andreas_webe...
Offline Send Email
Mar 12, 2007
7:02 am
694
I will be out of the office until March 9th. Please excuse the delay in responding to your email. ... To: <comis@yahoogroups.com> From: "Andreas Weber"...
David Bradley
tesstrnsys
Offline Send Email
Mar 12, 2007
7:02 am
695
Dear Andreas Thank you for quick reply. After copying Type157.dll, I had another error message: Visual Fortran run-time error forrtl: severe (29) file not...