Vijgandhi, To answer your question I never put the device group name or device number in the create device statement. After the symmetrix assignes a symdev #....
Hi, In our setup somewhere we have used metadevices and some where where we don't? Is there any particular reason (except to full fill large size requirement...
VJ: We use MVs when: 1. On Windows we need a single volume bigger than a HV. Our HVs are generally 8 GB and we may need 32 GB MVs on Windows. 2. In some...
While running symdg list one device group seen as Invalid.and symld -g dbdg list also shows dbdg as invalid.Is it necessary to full establish dbdg device...
... symld -g ... establish ... of ... BCVs ... Here I am also able to import and deport group using veritas volume manager and also able to start volumes...
It may be caused by something like a single invalid track between your R1/R2. Found a related issue on Powerlink for a known issue (Fix 16500...also see...
Rita Workman
RWORKMAN@...
May 6, 2005 11:33 am
575
I think this will not resolve my problem. becasue we have 5570.XX version in which this 16500 is already fixed that you are talking.. Regds, Vijay ... ...
In my experience this problem typically occurs when you perform a bin file or symconfigure change that involves a device that is in an existing device group....
... Looks like the individual device is invalid to me (although, I haven't seen this before). "symdev show <device>" will show you the device's status, so you...
When I "discover" EMC volumes on an HP-UX server I go through this sequence: symcfg disc ioscan insf -e symcfg disc ... Yahoo! Mail Mobile Take Yahoo! Mail...
HIII ALL WE NEED PROFESSIONALS WITH THE FOLLOWING SKILL SET Deep understanding of digital and analog circuit design on PCB-level ( no ASIC/VLSI design ) - Deep...
Hi; First of all you have to edit "sd.conf" and "lpfc.conf" files. The second one can change according to your HBA vendor. After editing "sd.conf" file , you...
I like to just web into our departmental switches and do my zoning from there. http://<ip of switch> On Brocade switches you just click on the zoning icon at...
Rita Workman
RWORKMAN@...
May 11, 2005 11:17 am
586
Vijay, To create a hard zone on the Brocade CLI: zonecreate server_a, "1,0; 1,5" This specifies that "switch domain 1 port 0" will be zoned to "switch domain 1...
Hi, Suppose If we are using port based Zoning and some ports got bad. How to replace its configuration? If we are using soft(wwn) based zoning and some ports...
what do you mean the ports got "bad"? Do you mean the transceiver is having issues? Have you looked at this under an analyzer? Are you getting any light at...
port got bad means it is not working.It may be hardware problem. ... __________________________________ Yahoo! Mail Mobile Take Yahoo! Mail with you! Check...
Hi, In our setup, we have 3 EMC DMX San. Let say 123,456,789. DMX having 123,456 are in NewYork while 789 is in Toronto.Here in DMX which sid is 789 don't...
If there is no gatekeeper available, then the software will use any hyper associated with the FA. Having gatekeepers makes the process run faster and without...
Kochanski, Mark A
MKOCHANS@...
May 13, 2005 1:19 pm
592
All a gatekeeper does is provide an OS visible path the the Symmetrix Cache. Since every disk device on a symm has access to Cache, SymCLI will use any disk...
Hi, While establshing RDF devices, all devices becomes Synchorinized except one device (0113). Already 6 hrs. passed away. It shows same thing. I have checked...
Hi, Today One HDD failed on our EMC BOX.I found the location using symevent,symdev,symdisk command. This time Hot Spare is notinvoked.Last time When Hdd was...
I need to set up an Ehchange cluster on a CX700. when presenting the disk to the hosts (using Veritas Volume Manager), should I present all the disk to each...
Dave asks: I need to set up an Exchange cluster on a CX700. when presenting the disk to the hosts (using Veritas Volume Manager), should I present all the...