1 FMEA Info centre
fmea@... Send Email
Feb 8, 2000
3:47 pm
Hi, We started a discussion group dealing with all aspects of FMEA - Failure Mode and Effects Analysis. Your messages will be send automatically to all...
2 FMEA Info centre
fmea@... Send Email
Feb 22, 2000
8:31 am
Hi, We've updated the website once more with about 50 sites (you can find the list of new sites under Latest Updates). An easy way to look for specific info on...
3 FMEA Info centre
fmea@... Send Email
Mar 4, 2000
7:56 pm
Hi, This short note to inform you that we have now 200 members on the FMEA discussion list. You can use the list for asking questions, sharing ideas, start...
4 Paul Rock
rockqmc@... Send Email
Mar 4, 2000
8:09 pm
5 KOAY CHEE MING
cmkoay@... Send Email
Mar 6, 2000
7:58 am
Hi, anyone got FMEA case study, especially for equipment reliability one?? Please kindly help. thanks. Regards....
6 Trevor Smith
trevor.smith@... Send Email
Mar 6, 2000
9:30 am
Dear Friends, Is there anyone out there who has practical experience of applying the technique on the software field? I very much think that the benefits of...
7 Dobry Alexander (T/DS...
Alexander.Dobry@... Send Email
Mar 6, 2000
3:21 pm
Hi Trevor! We donīt do software-FMEAs, but during the conception phase we analize all functions of our system and their interrelationships. Most of them are ...
8 Peter_Stoner
Peter@... Send Email
Mar 6, 2000
3:21 pm
Trevor. I find it best not to modify the rating system to suit applications, just read in software at the critical point. Forget the fact that they are ...
9 Haluska, John S.
HALUSKAJ@... Send Email
Mar 6, 2000
6:34 pm
Hi: Just last month we started doing aircraft level avionics FMECAs. We started at the top with "pilot observed functions". The input to each function has a ...
10 Steve Pickett
SPickett@... Send Email
Mar 6, 2000
6:35 pm
Greetings! I agree with Peter that you don't need to change your rating system when dealing with software, if you have a satisfactory system in place. I agree...
11 Robert Cassidy
rcassidy@... Send Email
Mar 7, 2000
8:06 am
Trevor: You may find some help at www.sae.org/products/papers. There is a document # 982816 entitled "Failure Mode Effects Analysis in Software Development"....
12 kurt l
kurt.lintermans@... Send Email
Mar 20, 2000
11:59 am
Hi , Firstly we'll introduce ourselves. We work with two engineers on a project that handles safety , the starting point is the IEC standard 61508 , the...
13 Dobry Alexander (T/DS...
Alexander.Dobry@... Send Email
Mar 20, 2000
7:16 pm
Hi Kurt, we develop electronic braking systems for trucks. We do FMEA for 15years and we use intelligent FMEA SW-Tools for two years now. Since these tools ...
14 Peter Russell
prlf@... Send Email
Mar 20, 2000
7:17 pm
Try, Simon Brailsford Customer Support Manager, Relex Software (Europe) Ltd Telephone +44(0)1889 579 100 Facsimile +44(0)1889 579 300 Email...
15 FMEA Info centre
fmea@... Send Email
Mar 21, 2000
8:36 pm
This short note to inform you we've updated the FMEA Info Centre site. We've collected abstracts of technical papers about FMEA (1999-1996). You can find the...
16 Paulo Dinis Oliveira ...
ergosoft@... Send Email
Mar 23, 2000
8:06 am
Hi to all members ! This is my first participation on this mailing list. Iīve read some things about FMEA thankīs to the site you refered to. Iīm mostly...
17 Cris Whetton
ility@... Send Email
Mar 23, 2000
10:48 am
At ility Engineering we use FMEA mainly on chemical process plant and in three main areas: Safety-critical systems, such as trips and shut-down systems. ...
18 Paulo Dinis Oliveira ...
ergosoft@... Send Email
Mar 25, 2000
11:27 am
Hi to all ! I have found some example of FMEA for quality issues. Since i didnīt get any repllys from my anterior posting here is the second. In the risk...
19 Wijnants, G.H. (Geert...
GeertHenk.Wijnants@... Send Email
Mar 28, 2000
8:46 am
Hi, who has data available from experience for the following topic: * the chance of leakage of heat pipes, as present in induction heated rolls. Can sealwelds...
20 Dobry Alexander (T/DS...
Alexander.Dobry@... Send Email
Mar 29, 2000
9:37 am
Hi, sorry I canīt give you a satisfying answer, but if we donīt have any expierence with a product and its possible malfunctions we set their occurrences...
21 Laura E-Mail
lauram@... Send Email
Mar 29, 2000
9:40 am
As far as my experience...the Detection column is intended for the ability to detect the defect in the process. Errorproofed processes...ie, no chance to be...
22 Leonardo Miracca
leonardo.miracca@... Send Email
Mar 29, 2000
9:43 am
Hi to all, Can anyone send me any practical info (or where can I find it) on utilising FMEA techniques within the automotive supply sector? Thanks in advance! ...
23 Dobry Alexander (T/DS...
Alexander.Dobry@... Send Email
Mar 29, 2000
9:46 am
Hola Paulo, The third column describes detectability - the probability to detect the cause of a possible failure. For a D of 10 (System/Design FMEA) we say: It...
24 FMEA Info centre
fmea@... Send Email
Mar 29, 2000
10:24 am
Hi, This short note to inform you that we will split the activities of the current FMEA list in two lists: fmeainfo@egroups.com will remain the...
25 Dobry Alexander (T/DS...
Alexander.Dobry@... Send Email
Mar 30, 2000
11:28 am
Hi, there are different descriptions of the procedure: I recommend: VDA 4 part 2 Quality Assurance before serial introduction - System FMEA. http://www.vda.de/...
26 Howard Atkins
quality@... Send Email
Mar 30, 2000
11:29 am
Try http://www.qs9000.com/cgi-bin/Ultimate.cgi -- Howard Atkins, Quality Manager Raviv Precision Injection Molding, http://raviv.com/ Kibbutz Revivim, D.N....
27 MikeSignor@... Send Email Mar 30, 2000
11:34 am
I have found several other useful sources on FMEA in software development. Does anyone know of additional articles? Here are the best I have found: Ammar, H....
28 Thonissen, Robert (R.)
rthoniss@... Send Email
Mar 30, 2000
5:39 pm
Dear ALL The FORD Fmea Standard is Available in next languages: English Dutch French German Spanish Italian and Russian are in process. The FORD procedure...
29 fmea@... Send Email Apr 1, 2000
8:09 pm
Robert Thonissen (see below) from FORD has send us a document concerning Design FMEA. According to Robert this can give an answer to most of the questions that...
30 Harish Garg
nitirnd@... Send Email
Apr 4, 2000
12:49 pm
Hi to all, Can anyone send me any practical info (or where can I find it) on utilising FMEA techniques within weighing scale and systems. Thanks in advance! ...