The 2004 version of the DGR pg 210 shows UN 1263 PG II as 5L on passenger aircraft. I don't have my 2003 to confirm if this is a change. "Michael L. Clements"...
If your shipping 1 container containing 5 liters you must us pkg inst 305, glass containers 1 liter max. No matter what configuration of your pkg. 5 liters is...
You will also need to perform a TSCA notification. Goble McCoy <gm43110@...> wrote:If your shipping 1 container containing 5 liters you must us pkg inst...
One more correction to my post regarding the upcoming CAMEO course at the New York State Academy of Fire Science. The catalogue clip I snipped in my previous...
Does anyone know of a source of Security Awareness Powerpoint slides that would be used for HM Security Awareness training? I'd be willing to trade some of my...
Next year in the IATA regulations the overpack marking requirement is simply going to be the word "Overpack". Yet DOT still has, I presume, the "Inner packages...
I was speaking with an FAA agent a while back and asking if they regularly followed up with companies they'd opened cases against -- or at least a letter --...
Does anyone in Texas offer the new CAMEO course? I remember a number of years ago, the class was offered through the Department of Health. Anyone in the...
A day late and a dollar short - an EPA Region 6 CAMEO workshop was held last May in San Antonio. The workshop was coordinated by the Bexar County Local...
Homer.Emery@...
Oct 5, 2004 12:30 am
5588
What level of entry would you consider Firefighting gear with an SCBA at a gas leak? Paul Logan Virginia Beach Fire Dept. Hazmat Team 600 Central Dr Virginia...
Paul Logan
PLOGAN@...
Oct 5, 2004 7:43 am
5589
In a message dated 10/5/2004 2:43:58 AM Central Standard Time, ... [Non-text portions of this message have been removed]...
"What level of entry would you consider Firefighting gear with an SCBA at a gas leak?" --- Paul Logan, Virginia Beach Fire Dept., Hazmat Team ... Level D. ...
Alton Lanier
altonl@...
Oct 5, 2004 2:27 pm
5592
I would consider turnouts with an SCBA to be modified level D PPE. You have to remember that the type of incident has nothing to do with the definition of the...
If I remember all my levels correctly (I hope I do as I often teach this, but I'm off the cuff here), I would put SCBA/firefighting gear at a Level B. The big...
David Roberts
droberts@...
Oct 5, 2004 2:27 pm
5594
What kind of gas Paul: Flammable, non-flammable, poison, cryo, big leak, little leak, inside a facility, outside a facility, wind, etc. If you are gonna be...
Hospital Emergency Response Training for Mass Casualty Incidents Train-the-Trainer, B461 Course. Offered at the Noble Training Center in Anniston, AL, and also...
Firefighter turnouts are considered level 'D' in the Haz Mat world but you have to choose your PPE according to the greatest hazard. If this is a natural gas...
There is very little firefighting gear out in the ff world today that has any chemical protective properties. FF T/O gear is designed for fighting fires... ...
Greene, Martin (DFS)
Martin.Greene@...
Oct 5, 2004 10:08 pm
5599
I would agree. The SCBA puts it at a level B. David Roberts <droberts@...> wrote: If I remember all my levels correctly (I hope I do as I often teach...
I would not enter if LEL indicate 20% or above. If gas leak is propane, I would measure LEL near floor, if gas leak is methane, I would measure LEL near...
Immo Tilgner
Immo_Tilgner@...
Oct 5, 2004 10:09 pm
5601
In a message dated 10/5/2004 10:02:28 AM Central Standard Time, Trngassoc ... 1. levels A & B use supplied air and CPC. The only difference is that level A ...
There is a German company called Karcher based in Winneden Germany that has a specialist NBCF division Nucleur Biological Chemical & Fire Decontamination that...
That doesn't help the 2+million first responder who may have been told that their structural gear provides "Limited Protection" "Dave Marock 24HR" ...
Greene, Martin (DFS)
Martin.Greene@...
Oct 6, 2004 3:11 pm
5605
Remember, the levels of protection are primarily based on respiratory protection. ... I would agree. The SCBA puts it at a level B. David Roberts...
Les Cartier
lcartier@...
Oct 6, 2004 3:12 pm
5606
Thank You Mr. Howell! Industry is doing research and someday soon structural fire fighting clothing may have chemical protective properties. Many of us in the...
Greene, Martin (DFS)
Martin.Greene@...
Oct 6, 2004 3:12 pm
5607
Good Afternoon Group I have a bit of a problem with applying the NFPA 704 Standard and am hoping that someone can enlighten me. Having read the 2001 version,...