A good place to start to see what "sense" and the data resulting from issuing that command is with just about any Principles of Operation for a mainframe; I...
Thanks, I changed the deffinitions to say drain and I did a cold start to make sure, but when I reboot I get the following situation: *STC 10 *$HASP190...
The parms you have should do it. HOWEVER, in the JES2PARMS see the highlighted commands which are your problem! Remove these and the problem should go away. ...
Thanks Scot, That did the trick ..... I also noticed that sometimes one of my terminals does not get connected correctly and then when I shut down vtam seems...
Thanks ever so much, can I ask a few more questions What is the difference between DRAIN and START ... it was START originally ) ... And why did these lines...
(Please trim your quotes to just what you're commenting on. The digest readers of this list will thank you.) ... They apply to an RJE station named RMT1. (You...
... "Drain" states that the printer is not to print even if there are jobs to be printed. "Start", which is the default, says to start printing when there are...
Why do the printers end up in a Halt state, after IPL even though the jes2parm says START ????? *IEA000A 009,INT REQ,09,0200,4000,,,*MASTER* *STC 44...
... When a printer any of the printer's device setup parameters (forms, carriage control, print train) change, it's halted to allow the operator to make the ...
How does setting the parm to DRAIN bypass this problem ?? From: hercules-390@yahoogroups.com [mailto:hercules-390@yahoogroups.com] On Behalf Of Jay Maynard ...
But that is another additional manual step :) blahhhhh So just out of curiosity can I reply two these messages: *IEA000A 009,INT REQ,09,0200,4000,,,*MASTER* ...
... - - - snipped - - - It is not you. Most newbies have the same problems. 1. Comment out unused consoles 009 and 011 from the turnkey configuration you...
So How much of the following is unneccessary: ( from jes2parm ) 000223 ******** *OPERATOR COMMANDS 000224 $TOSC1,D=J 000225 $TOSC2,D=J 000226 $TOSC3,D=T...
The following message is what I see when I use the new ones... ** tt32_loaddll: LoadLibraryEx("TunTap32.dll") failed; rc=14001: This application has failed to...
... - - - snipped - - - Get rid of: $SRDR1 *$SPRT1 *$SPRT2 $SPCH1 $VS,'S MF1.MF1' BSPPILOT trades reply U for P BSPPILOT BSPSETPF sets PF11 to set roll mode...
Hi, I have an Z/OS 1.4 under Hercules on Windows/XP SP2. Until now i work whithout any problem but today when I try to made an IPL to my system I receive next...
Max, Very nice job on the 3705/SNA work. (Hmm, that could be a massive understatement....) What would it take to support 3270 through this network interface? ...
Joseph, The following messages appear. The driver and the Hercules software has been installed in the directory c:\zos\hercules-3.04 . This is also included in...