What's new in version 1.9.5 build 4734:
Fixes:
* Fixed devinit/attach for Display Terminals
(Terminal Group required; '*' if none)
* Fixed(?) hung [Hercules] process detection / handling
* Fixed bug causing rejection of 3-digit device addresses
* Corrected recognition of certain DasdLoad progress messages
* Corrected issue where clicking 'OK' from the System
Configuration
dialog after having Powered On without actually making any
changes
would mistakenly cause HercGUI to believe the active
configuration
file had been modified.
Enhancements:
* HercGUI now logs which Preferred executables directory is being
used at Power On
* The default Logging Preference option is now "Automatic"
* New Misc2 Preference option to suppress manual edit reminder
warning
msgbox
* Button added to command-line bar to set 'sh'ell command target
directory (requires accompanying Hercules 3.03 support if Misc
'sh'
command Preference set to "Let Hercules issue the command")
* Complete redesign of System Configuration dialog: is now a
multi-page
Property Sheet dialog instead in order to have room to support
the
many new/existing configuration file settings/statements
* Added support for some new Herc config file statements: OSTAILOR
ZOS,
ARCHMODE z/Arch (same as ESAME), SHCMDOPT, and ALRF (synonym for
ASN_AND_LX_RESUSE)
* Moved the "Modify settings" and "Modify devices" commands from
their
original more cumbersome(?) submenu location directly into the
"File"
menu itself where they're more easily accessible
* Added support for new DASDCONV utility
* Tweak Percent Utilization Meter handling to hopefully be less
jumpy
* cpu-types.txt: Corrected/updated/added entries for zSeries z890
and
new System z9 109 series CPU models as well as the names of
existing
zSeries models as per current IBM documentation
* CTCI/CTCT device statements now use the more proper 'new' format
(devtype 3088 deprecated)
* Added support for new 1052-C and 3215-C Integrated Console
Printer
devices
* Add support to TAPECOPY utility dialog for copying SCSI tape
both to
-or- from AWS files since new Hercules 3.03 now supports copying
in
either direction.
* The Devices Configuration dialog now remembers/restores its
previous
size/position
* Improved restoration handling of main window's previous size and
position
* Updated some existing minimum, maximum and default "registry
tweak"
values and added/documented some new ones
URLs:
HercGUI index:
http://www.softdevlabs.com/Hercules/hercgui-index.html
What's New:
http://www.softdevlabs.com/Hercules/hercgui-whatsnew.html
README:
http://www.softdevlabs.com/Hercules/hercgui-readme.html
Direct download URL:
http://www.softdevlabs.com/Hercules/HercGUIv1.9.5.4734.exe.zip
- --
"Fish" (David B. Trout) - fish(at)infidels.org
Fight Spam! Join CAUCE! <
http://www.cauce.org/>
(Any HTML email received will be deleted unread)
PGP key fingerprints:
DH/DSS: 9F9B BAB0 BA7F C458 1A89 FE26 48F5 D7F4 C4EE 3E2A
RSA: 6B37 7110 7201 9917 9B0D 99E3 55DB 5D58 FADE 4A52
-----BEGIN PGP SIGNATURE-----
Version: PGP 7.0.4
iQA/AwUBQ6sdwEj11/TE7j4qEQKD3gCgnFO2Pt+mlAwZXoGklbov8Nrl+zwAn1EX
KuA7jYMzmfa3UjeSw0HCvEwI
=bNdE
-----END PGP SIGNATURE-----