Charles, Thank you again. Killing all the processes and then deleting the lock files did the trick, as things seem to be back to normal. The batteries are...
Hey guys, am LOVING the power of scripts! Anyway here is a current line from my x10config: SCRIPT A16 on sndc sndm :: ( (($x10_towel_warmer == $isOff)) ) && ...
... current ... && ... 512, ... the on ... Brilliant! works like a charm. As I elluded to in the intial post I have the outlet listed as a StdAM I also list...
On Wed, 08 Feb 2006 21:28:06 +0000 ... StdAM is appropriate for the outlet. It will work for the motion detector, although REMOTE2 would be more appropriate...
Charles: It absolutly makes sense and I will proceed accordingly. Now that I can handle the condintional stuff I need to replace all of my current x10...
... them ? ... Bob, it should be pretty clear in the description if not reflected in the price. search two-way on smarthome.com and you should get a pretty...
... Did you mean "3-way"? (As in the typical arrangement with two light switches such that either can turn a light on or off?) (And yes the term doesn't make...
... Oh, THAT kind of "2-way". There aren't all that many choices, but as bobme1234 suggested, search smarthome.com for "2-way" and you will get a list. Most...
On Thu, 09 Feb 2006 20:01:26 +0000 ... Have you been having any particular problems with your 1-way switches? The major problem I see is that there's no signal...
... that I ... current ... switches? ... Charles, that is exacltly the reason, the transmit piece. Why I ever bought one ways I dunno! butI just couldn't...
On Fri, 10 Feb 2006 15:00:42 +0000 ... I don't know how many switches you have in your setup, but you may want to analyze how your system is used before...
Download this new release from http://www.heyu.org There are a number of substantial changes in this release which can potentially break existing scripts,...
... <cwsulliv01@> ... Now ... my ... over ... doesn't ... the ... the ... elegant ... GREAT MINDS... Charles I spent the weekend really thinking about the...
On Mon, 13 Feb 2006 17:18:13 +0000 ... A Smarthome LampLinc 2000STW plug-in dimmer will send an X10 On or Off signal when it's manually switched. You'd have...
... usage ... first ... 10 ... if ... the ... and if ... wife ... an ... is ... than ... wifes ... can_lights_off ... && heyu dimb A1 4 ... the wall ... &...
On Mon, 13 Feb 2006 20:22:08 +0000 ... The SwitchLinc 2384W is only 1-way, i.e., receive-only, so my script suggestions won't work with it. The SwitchLinc...
... <cwsulliv01@> ... and ... The ... out ... on, ... when ... not be ... so ... my ... has ... intent ... more ... then ... heat ... house.... ... On or ... ...
... In North American wiring, this would cause all manner of problems, in addition to being a code violation. (I'd assume it's a similar situation elsewhere...
... far ... between ... "required" ... in ... situation ... but I'm ... Well not here in good 'ole Illinois, only in Polyphase implmentations would...
... I'm curious -- can you point me to the particular paragraph in the NEC (assuming that is the code you're referring to) where this would be considered...
... Chicago is, of course, in Illinois, but I can agree that the Chicago code is more stringent than Illinois. In Chicago, for example, conduit is an absolute...
... neutral ... Chicago code ... is an ... issues in ... suggestion that ... anywhere in ... loop ... leakage ... amounts of ... "neutral". This ... ...
... conduit ... to ... and ... advil ... be ... Okay in retro, that message may have been a bit tirt... that said, i've never had an issue and have enough...
Hi all, I think there was a discussion about this before but I can't seem to find it anywhere. I'm running Fedora Core 4 and Heyu 1.35_3 and each time I reboot...
I decided to update to the latest Heyu version and downloaded 2.0b4. I am using linux kernel 2.6.15-1.1831_FC4 and gcc (GCC) 4.0.2 20051125 (Red Hat 4.0.2-8). ...
On Tue, 21 Feb 2006 14:11:03 +0000 ... See: man udev It's been a while since I fiddled with this on my FC 3 system, but _think_ what did the trick was adding...
On Tue, 21 Feb 2006 15:08:49 +0000 ... I think the warning message for that particular line at least results from the target of sprintf being declared as an...