Search the web
Sign In
New User? Sign Up
heyu_users · heyu users
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Hear how Yahoo! Groups has changed the lives of others. Take me there.

Best of Y! Groups

   Check them out and nominate your group.
Having problems with message search? Fill out this form to ensure your group is one of the first to be migrated to the new message search system.

Messages

  Messages Help
Advanced
Messages 654 - 684 of 3754   Oldest  |  < Older  |  Newer >  |  Newest
Messages: Simplify | Expand   (Group by Topic) Author Sort by Date ^
654
I keep getting this error intermittently: "Interface not ready - received 5a" What is causing it, and how can I get it to stop. It is causing some of my cron...
K
klmcwhirter
Offline Send Email
Mar 6, 2004
9:07 am
655
On Sat, 06 Mar 2004 09:07:24 +0000 ... Please describe in detail how you are using heyu2 in your cron job when you get these messages. Regards, Charles...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 6, 2004
2:40 pm
656
I am using a cronjob the loooks like this 0-59/5 * * * * root /usr/bin/mrtg2/mrtg /etc/mrtg2/mrtg.cfg ... in the mrtg config I call mrtg-roomtemp "House Temp" ...
K
klmcwhirter
Offline Send Email
Mar 8, 2004
8:12 pm
657
On Mon, 08 Mar 2004 20:10:42 +0000 ... What's happening is that heyu2 is waiting for a message (0x55) from the CM11A that it's ready for the next command, but...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 8, 2004
10:35 pm
658
I have a question about my TempLinc. I've programmed it to 'Report on change' in the Fahrenheit scale. House code of 'L'. (ie, heyu2 address L1 L1 L1) When I...
Nigel Croxon
noxcash
Offline Send Email
Mar 10, 2004
3:14 am
659
My guess is that you have the sensor located too close to the heat source, i.e., directly over a radiator or in the airstream at the outlet of an air duct. ...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 10, 2004
12:06 pm
660
I have a cron job that cycles my cameras on the hour. I think that is it. Here is the output from the command you suggested... Version:2.00ALPHA-4 Searching...
K
klmcwhirter
Offline Send Email
Mar 10, 2004
4:48 pm
661
That 0x5b is the CM11A reporting that an uploaded macro has been executed, and it looks like it may be interfering with the temperature report signal from the...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 10, 2004
5:14 pm
662
Triggers might cause this collision? I could very wasily have a motion sensor triggering an event (Guest announcer, light on, or camera on action, while the...
K
klmcwhirter
Offline Send Email
Mar 11, 2004
3:37 am
663
Yes, the 0x5b message from the CM11A is sent regardless of whether the macro is executed by a timer or a trigger. (The trigger signal itself is not reported...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 11, 2004
5:07 am
664
(For users familiar with heyu 1.xx but unfamiliar with the enhancements made in heyu2, the earlier release notes beginning with those for heyu2 alpha-1 follow...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 12, 2004
8:28 pm
665
It is close to a source, I've moved it...and trying again. (are you peeking in my windows, chuck?) -Nigel...
noxcash
Offline Send Email
Mar 13, 2004
2:08 am
666
I'd appreciate hearing from anyone who has tried heyu2 alpha-5 on a PC under SuSE Linux version 9 - whether or not any basic problems were encountered. Thanks...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 16, 2004
7:54 pm
668
I'm also getting a seg fault with SuSE9.0 Alpha-5.0 compiled fine, heyu2 erase, followed by heyu2 upload then seg fault. I have to do yard work now. Will look...
Maria Machete
mmachete95
Offline Send Email
Mar 20, 2004
3:58 pm
669
Mark, Looking at your results, it appears that you entered 'heyu erase' rather than 'heyu2 erase', and would therefore be getting a segfault with both heyu and...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 21, 2004
1:40 pm
670
On Sun, 2004-03-21 at 08:40, Charles Sullivan wrote: Morning Charles, Ah the crucial missing information! I found typing heyu2 a nuisance so I made an alias in...
Maria Machete
mmachete95
Offline Send Email
Mar 21, 2004
2:58 pm
671
Heyu2 alpha-5 has been re-released with fixes for a few serious bugs, including a segfault under SuSE Linux ver 9. Download it from...
Charles Sullivan
itsahoot401
Offline Send Email
Mar 22, 2004
2:46 am
672
Thanks for the additions... I forsee some script writing in my near future. <g> # heyu temp_req preset j5 1 2004/03/30 16:26:18 Temperature = 76 : Location J...
K
klmcwhirter
Offline Send Email
Mar 31, 2004
12:35 am
673
I know this isn't the xtend support page but since I'm using your modified version of xtend I figured I might post here. I have the following lines in my...
Natch
natchswing
Offline Send Email
Apr 2, 2004
3:57 am
674
On Fri, 02 Apr 2004 03:57:49 +0000 ... Where is Xtend finding its configuration file when it's run in /etc/rc.d/rc.local ? I might suggest you take a look at...
Charles Sullivan
itsahoot401
Offline Send Email
Apr 2, 2004
4:47 am
675
... Not sure. Good point, I always login as root so I just use /root/. xtend assuming it was the default config location. I'll look into that. ... Nothing...
Natch
natchswing
Offline Send Email
Apr 5, 2004
4:19 am
676
On Mon, 05 Apr 2004 04:19:00 +0000 ... Shudder!!! ... heyu2 and its config file and man pages are different from heyu 1.xx so you can switch back and forth...
Charles Sullivan
itsahoot401
Offline Send Email
Apr 5, 2004
5:12 am
677
Hi, OK, so I've installed heyu 1.35 on a Redhat 7.1 box and seem to be able to load a schedual into the CM11 OK. But I haven't been able to figure out a few...
feamane
Offline Send Email
Apr 17, 2004
1:58 am
678
Hello all, How do I 'heyu2 monitor' multiple house codes? Version:2.00ALPHA-4 My x10.conf file has housecode A specified. But I want to set my motion detectors...
Nigel Croxon
noxcash
Offline Send Email
Apr 17, 2004
11:26 am
679
On Sat, 17 Apr 2004 07:24:36 -0400 ... The heyu2 monitor displays X10 power line signals for all housecodes, not just the base housecode of the CM11A. Run...
Charles Sullivan
itsahoot401
Offline Send Email
Apr 17, 2004
12:57 pm
680
On Sat, 17 Apr 2004 01:58:55 +0000 ... If heyu is working properly, the heyuhelper script will be executed every time any X10 power line function signal is...
Charles Sullivan
itsahoot401
Offline Send Email
Apr 17, 2004
2:08 pm
681
Many PC's sold today are not equipped with RS232 serial ports, only USB ports. I decided to see how well heyu2 would work under Linux using a USB-to-Serial...
Charles Sullivan
itsahoot401
Offline Send Email
Apr 17, 2004
3:39 pm
682
See: <http://www.x10.com/products/firecracker/index_firecracker.htm#> Pay $5.90 for S&H in USA. They'll probably add you on their mailing list. The X10...
Charles Sullivan
itsahoot401
Offline Send Email
Apr 17, 2004
9:44 pm
683
... Everything is working fine.... heyu2 upload... heyu2 info...all fine.. ... I have the TM751. ... Set tm751 to house code B.. set X10 MS14A to house code...
Nigel Croxon
noxcash
Offline Send Email
Apr 18, 2004
11:54 pm
684
On Sun, 18 Apr 2004 19:52:04 -0400 ... One frequent problem occurs when a transmitter (like the TM751) and a receiver (like the CM11A) are on different phases...
Charles Sullivan
itsahoot401
Offline Send Email
Apr 19, 2004
2:10 am
Messages 654 - 684 of 3754   Oldest  |  < Older  |  Newer >  |  Newest