I have been having no luck getting my CM12 running with heyu. I hope someone here can help. The device is plugged into /dev/ttyS1, verified with another...
What are the permissions on /dev/ttyS1 ? $ stty -a </dev/ttyS0 speed 4800 baud; rows 0; columns 0; line = 0; intr = <undef>; quit = <undef>; erase = <undef>;...
Nigel, The 0x8b is the character sent from the PC to tell the CM12 to return its 14-byte info block. It's a puzzler why the CM12 would merely echo back the...
... hope ... serial ... line ... A few things: With kernel 2.6 I noticed that serial ports were moved slightly, but at least Gentoo (maybe other distros do...
On Fri, 29 Apr 2005 16:24:24 +0000 ... I presume you are using heyu-2.0beta.2 - if not, you should be. Man pages for this release are heyu(1), x10config(5),...
Thank you sir. I believe my mistake was in installing the binary package only. I'll give it another go from code. ... anywhere? ... x10scripts(5). ... pages...
hello, working on a HMI in php with a heyu backend: has anybody a nice ereg expression to validate an address as described in the man? /* Housecode is an upper...
On Mon, 02 May 2005 22:10:52 +0000 ... I'm not sure what you're trying to do. If you give heyu a command with an invalid address, it will display an error...
Hi, Suppose a device (Powerhouse Marmitek LM12F/BNL) on and fully dimmed down: it seems that the commands: bright 20, bright 21, bright 22 do all the same...
On Fri, 06 May 2005 08:15:05 +0000 ... Bright PLC signals are apparently transmitted by the CM11A according to the formula: brights = 11 * (level - 1) + X ...
Hi, Having complete my house move and rebuilding my systems. I started Trying out my X10 stuff. This is my first attempt using White Box Linux. The build...
... I don't use heyu, but I just had this exact same problem when migrating x10bot and devx10 over to a new box using CentOS. I could communicate with the...
On Mon, 09 May 2005 16:30:22 +0000 ... One problem could be excessive noise on the AC line. Try moving the CM11A to different recepticles in the house with a...
I have run into the same problems with my CM11A... I was able to resolve my issue by moving the CM11A to a different location, which was much closer to the...
hi...sorry for my english..but i'm italian. I have a problem whit heyu and xtend... xtend don't work whit my CM11 and don't work whit my patched heyu.. can...
On Wed, 11 May 2005 18:21:52 +0000 ... Xtend is no longer needed - all its functionality is built into heyu-2.0beta.2 See the man pages x10config(5) and...
On Mon, 16 May 2005 12:13:54 +0000 ... You should be using heyu-2.0beta.2 by this time, but the latest heyu2 alpha should work as well. The heyu monitor...
On Mon, 16 May 2005 12:13:54 +0000 ... You should be using heyu-2.0beta.2 by this time, but the latest heyu2 alpha should work as well. The heyu monitor...
hi charles, thanks for your response...very utils!! Now i'm using Heyu Version:2.00ALPHA-5.2... and whit SCRIPT fiore on sndc rcvi :: mkdir /root/ciao and ...
hi charles, thanks for your response...very utils!! Now i'm using Heyu Version:2.00ALPHA-5.2... and whit SCRIPT fiore on sndc rcvi :: mkdir /root/ciao and ...
All, I had a lot of problems getting X10 installed in my new house. The Electrical systems were mixed grounded, and ungrounded branches due to previous owner...
On Fri, 20 May 2005 09:12:02 +0000 ... If I understand correctly, you are turning on the appliance or lamp with the on/off switch on the appliance or lamp...
hi Charles, nothing...when i turn on or off manually the appliance o lamp...the command in script directive don't work!! -The output when i use the adapter...
On Fri, 27 May 2005 08:44:10 +0000 ... If you don't see a signal in the heyu monitor when you manually switch an appliance or lamp, then heyu doesn't know you...