Hi guys, It has been a long time since I posted on the forum, that I am practically a newbie. My life has taken me away from my beloved hobby, but I am trying...
National instruments and Agilent are normally the household names, i think prologix also makes them. Personally i would stick with Agilent or NI, you can pick...
Hi. Can anybody please suggest a source for the concentric knobs on the front panel? I just bought a 8005B and it has 3 of the larger concentric knobs missing....
Could it just be lack of contrast / brightness ? I don't have a 54622A but maybe the display brightens on the element you change, and when it reverts to normal...
Thanks Adrian, you were absolutely right. It was a bad resistor in the brightness circuit. It is funny, but I did not suspect a brightness problem until you...
I'm switching from an NI PCI-based GPIB controller to the Prologix GPIB-USB adapter. So far, everything is going well. However, I already have a problem...
... When I was programming with the NI low level commands using the PC2 and PC2A cards I seem to remember using those commands. I would suggest getting a hold ...
Anyone have a 8556A and 8552B parts unit they would wish to sell to me? I have a non working pair of unit that I am trying to rebuild. If i could put a pair...
Hi gang, I got the HP3476A Digital Multimeter yesterday on a previous Ebay purchase. I'm happy to say it's working fine. The dIsplay is nice and bright, AC/DC...
Arbor Communications Palo Alto, CA June 1979. The CRT display and switches work, the beautiful blue case resembles the old HP. No manual but the connections...
... OK, I'm curious - wouldn't these show up when doing a search from: http://www.home.agilent.com/agilent/facet.jspx?lc=eng&cc=US&t=80039.k.1 Or perhaps not? ...
Yes They all show up in search...but you also get a lot of stuff you "dont" need with search. The listing this way is really kind of useful Dave Dave & Lynn...
I posted some 26 GHz Agilent stuff on the hpagilentswap group and it doesn't seem to be showing up. Is there a delay on postings to the group that I'm not...
Hi all -- I have a 204C that has acquired a ~30KHz rider. Is this the stuff the manual refers to when telling one to select a higher value for A1C9? Mine has...
Greg, Yep, it's there now. I heard privately from a couple of folks that had the same trouble with both the swap group, and the Tek group, so perhaps Yahoo...
I am trying to get the frequency values from the Wiltron Sweep Gen to show on the screen of the HP Network Analyzer. I set the GPIB of the Sweep Gen to Address...
I have a working unit but the blue gun/channel for the display is out. I just have RG of the RGB working. Anyone have a similiar experience ? Difficult to...
Dana wrote: Also has anyone modified the measurement capability or firmware to do FFT w/o going thru HPIB to another program ? I have a 54111D and too am...
Hello, If I am not mistaken JOSE V. GAVILA http://jvgavila.com worked on this scope. Look him up, he has a lot of information on his website. Jurgen ... From:...
Does anyone know the crystal frequency of a National Instruments AT GPIB card circa 1988. I just received one which I would like to use but the crystal has...
The test to isolate failure is pretty easy..... exchange the green and blue wires to the display..... If blue is still bad, it's the tube..... if green is...
This is a PM1034A Pacific Measurements/Wavetek RF power meter. Subject line sez all. No luck at the usual suspects I've tried so far. Regards DaveB, NZ...
If that's the same as a standard Wavetek 1034A portable power meter, it looks like www.manualsplus.com has a "fair" paper copy for sale at US $45. Search for...
Thanks Dan. That gives me a starting point. The unit I have, a 180625 assembly, uses a discrete crystal interfacing a NI 700454-01 TURBO488 chip and is an...