I do a lot of restoring. I use amonia and a small ultrasonic bath. I have tried some small pcb's in that and they come out real nice. I use it also to clean...
I posted this on the Agilent site support forum and so far nothing. Anyone here have any thoughts on this or even tried it? Options 001 (second IF out) and 005...
Hi I have two questions on the HP8754A which I hope someone can answer. 1. Does anyone have a copy of the Operating Instructions please? I have already...
Hi Tony, ... Yes!!!. Here you have it: http://www.hparchive.com/Manuals/HP-8754A-Manual.pdf ... I could look next time I open my unit but from memory, no idea,...
I know this is a real long shot of finding one but I would like to buy the N coax connector adapter for a Boonton/HP 250 Rx meter. David KW4DH -- National...
... Join the club! I managed to get the transistor test adaptor set some years ago, but have failed miserably to find the N-coax adaptor. I tried pretty hard...
Hi guys I saved all the posts related to the 8165A and have just today got her back on the bench. Apologies for re-hashing this but after reading all the...
Hello, I know this is not related to the type of equipment you generally talk about. I have an 7210 hp printer and would like to repair it. Cant find any ...
27256
Mark Kahrs
mark.kahrs@...
Mar 1, 2010 2:50 pm
You might try: http://www.fixyourownprinter.com/ They have advice and a forum section. ... [Non-text portions of this message have been removed]...
Comments: Ultrasonics can break wirebondsin ICs. Be careful aboutwashing tubes. Water and ammonia can remove markings. Ditto chassis part number markings. ...
Thanks, I did not know that. Upto now the pcb's tested had no IC's but switches and resistors. ... [Non-text portions of this message have been removed]...
A couple of years ago, I made a run of clone CRT overlays for the HP 8505A VNA. I sold out that run and have had a couple of requests for overlays since. I do...
Probably. The shape looks right, but I don't have the energy to confirm the dimensions. If they called it "size 8" then it's right. You don't say which TG...
Thanks for the info. Regretfully it is too far to get to from the UK to do the pick up, otherwise I would be bidding on the HP 4192A (and probably way too many...
Guys, with water it is ok, you can find a way to get rid of it, but what happens when Coka Cola falls on a motherboard? How could you clean it then? ; Thanks,...
Scrub a dub dub! Cleaning up Coke is no different than cleaning up the water soluble fluxes. Remove the socketed IC's, batteries, etc. And wash away! Dry in a...
`Hi, I would carry it immediately to the nearest dish washer and put on full cycle. I know some parts may get damaged but that would not scare me like coke...
Yup not as bad as Pepsi but needs to be at least rinsed off asap or sooner. ;-] Phosphoric acid is one of coke/pepsi ingredients Never have tried the...
Hello, Thanks to all who took their time and offered me their advice for cleaning water damaged equipment... I am in awe by Tek, HP and other manufactures who...
Hi Luis, You didn't mention if it was for a A or B model (don't know if there is any difference). Anyway, about your backup question, just let you know I...
Hi Soulis, I've been told by a radio-ham of my friends, who is also an electronics engineer in a car equipment company that they are sometimes hired to perform...
Depends if the board was powered or not: If NOT powered, just wash in warm water a few times, rinse with distilled, air blow, and bake. It it WAS powered, you...
Or diet soda! Years ago, I drove to California. After leaving Salt Lake City and driving across the flats, my car popped a heater hose in Nevada. There was...
Richard, Â A lot of the electronics you buy gets tested in 55C and 80C. Like 24 and 48 hours burnin. I do not know of any damage I have done using the dish...
Hi Christian. I did the same and the folks at Agilent were very nice and sent me a CD too ;-) Mine is an A. AFAIK from the users perspective the only upgrade...