Reply | Forward Message #103 of 131 |

slm_event():  
The parameter lists for DATA_DIRECT and DATA_LINK are not in the same order (dataid, dataformatid and sequence counter)


The argument list for DATA_DIRECT:

• A Sequence of Octet containing the data values.
• A string with the dataformatID
• A string with the dataID
• A long value with the sequence counter


The argument list for DATA_LINK:

• A string with the data ID.
• A string with a sequence counter.
• A string with the dataformatID.
• An EDataLinkType defining the link type (Listing 25).
• A string with the link value.




Best Regards,
Thorsten


Thorsten Richter
Project Manager
--------------------------------------------------------------
CREON·LAB·CONTROL AG
Europaallee 27-29, D-50226 Frechen, Germany
Tel. +49 2234 9207-0 Fax. +49 2234 9207-99
http://www.creonlabcontrol.com
--------------------------------------------------------------


Wed Jul 10, 2002 7:45 am

creonrichter
Offline Offline
Send Email Send Email

Forward
Message #103 of 131 |
Expand Messages Author Sort by Date

slm_event(): The parameter lists for DATA_DIRECT and DATA_LINK are not in the same order (dataid, dataformatid and sequence counter) The argument list for...
thorsten.richter@...
creonrichter
Offline Send Email
Jul 10, 2002
3:19 pm
Advanced

Copyright © 2009 Yahoo! Inc. All rights reserved.
Privacy Policy - Terms of Service - Guidelines - Help