171
... Subject: Re: In reply to your question/comment Date: Thu, 22 Sep 2005 16:19:14 +0200 (CEST) From: Philips Semiconductors Support Application ...
AVS Electronics
suppgrg
Offline Send Email
Sep 23, 2005
9:26 am
172
Hi, you describe a problem that is listed in the Data Sheet and in the Errata Sheet. While I agree that this can be an issue for some applications, the Errata...
lpc2100_fan
Offline Send Email
Sep 24, 2005
8:59 pm
173
IMHO stating "reset is flawed" and "workarounds are available" is nice, but I would also expect upgrades to the chips with corrected known problems. I see...
Jan Waclawek
wekovci
Offline Send Email
Sep 26, 2005
6:52 am
174
I did not wanted to be polemical, nor I wanted to start a flame. I should say that I 100% agree with Jan: the purposes of LPCs can be disattended with this...
AVS Electronics
suppgrg
Offline Send Email
Sep 26, 2005
7:43 am
175
Hellow Jim, Dos this problem apply to all LPC900 and LPC2000 series devices? Regards, Pragnesh...
Sheth Pragnesh
shethpragnesh
Offline Send Email
Sep 27, 2005
4:01 am
176
This problem is not specific to Philips. I'm using a Microchip (not by choice!) rfPIC12C509 that exhibits this same problem. If you reapply power to it while...
tbavp
Offline Send Email
Sep 27, 2005
1:35 pm
177
Tom, here is what you are missing: If you switch off power, the voltage in your system will go down to a threshold of a diode drop rather rapidly. So the range...
lpc2100_fan
Offline Send Email
Sep 27, 2005
5:18 pm
178
Hello Pragnesh, this problem does not exist in the LPC2000 devices. Bob...
lpc2100_fan
Offline Send Email
Sep 27, 2005
5:20 pm
179
this is a email / a reply from Embedded Systems Academy ... Hi Harald, Version 2.40 of Flash Magic is now available that supports sending the CCP command. Go...
lpcharrylpc
Offline Send Email
Oct 26, 2005
9:05 am
180
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the lpc900_users group. File : /v15 ISP...
lpc900_users@yahoogro...
Send Email
Oct 26, 2005
7:12 pm
181
Hi everybody, I would like to introduce my LPC900 programmer for all of you who, like me, are fascinated with the Phlips micros. My program has the ...
opiedrahita2003
Offline Send Email
Oct 28, 2005
12:48 am
182
hi Andy, isp to icp bridge version 1.6 is available now! you can download it on the website: http://www.esacademy.com/software/flashmagic/ Best regards! Frank...
zhong yongbo
zhongyongbofly
Offline Send Email
Oct 31, 2005
2:55 am
184
hello, I want to know about UART performance. (1)In case of LPC900 series Microcontrollers use UART, How much will permissible range of error margin? (2)The...
yen0yuki
Offline Send Email
Oct 31, 2005
6:12 am
185
Hello, the permissible Error margin combined over the transmition of a byte including start and stopbit has to be less than half a bit. Half a bit is 50%,...
philips_apps
Offline Send Email
Oct 31, 2005
9:14 am
186
Enter your vote today! A new poll has been created for the lpc900_users group: Do you use ISP or ICP for your LPC900 design? o ISP o ICP o Already programmed...
lpc900_users@yahoogro...
Send Email
Dec 13, 2005
3:33 pm
188
Dear LPC9xx Users. Take advantage of one of the most powerful micros in the market, the LPC9xx. There is not reason to stay outside this fantastic world. The...
opiedrahita2003
Offline Send Email
Dec 14, 2005
3:26 pm
189
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the lpc900_users group. File : /USB-ICP...
lpc900_users@yahoogro...
Send Email
Dec 14, 2005
4:19 pm
190
All, application note 10258 'How to use the LPC900 In-circuit programming (ICP)' shows the configuration of PCL and PDA pins for LPC935 to be at p0.5 and p0.4,...
maciej_wiatr
Offline Send Email
Dec 25, 2005
9:01 pm
191
All, PHILIPS claims in the data sheets for the LPC9XX family that the MCUs can operate at 2.4V to 3.6V. Have you tried to get one of them run at 2.5V? I've...
maciej_wiatr
Offline Send Email
Dec 25, 2005
9:06 pm
192
Hi there, You need to disable 'brownout detection' in DEVICE CONFIGURATION. Then it will work upto 2.4V, else it will hang/reset/stop-working at 2.7V. Hitesh...
Hitesh Mahant
vital4all
Offline Send Email
Dec 26, 2005
3:20 am
193
Hi friends, I have two types of LPC922. One lot is LPC922F CCxxxx (TSSOP), other in LPC922FN CCxxxx. The verF is supporting multiple programming using ISP,...
Hitesh Mahant
vital4all
Offline Send Email
Dec 26, 2005
3:34 am
194
The LPC936 utilizes the P05 and P06 pins for ICP indeed. I've already programmed over a hundred devices this way. Gertjan ... documentation. ... too?...
geejee_lpc
Offline Send Email
Dec 26, 2005
10:02 am
195
I've had trouble getting LPC935-936 devices into programming mode too. What worked for me was to set the reset-output pin from the ICPISPbridge program to...
geejee_lpc
Offline Send Email
Dec 26, 2005
10:13 am
196
Gertjan, which of the two you mentioned is what? For LPC935: PDA - p0.4 PCL - p0.5 For LPC936: PDA - ... PCL - ... p0.5? p0.6? Can you point me to an internet...
Dr. Maciej Wiatr
maciej_wiatr
Offline Send Email
Dec 26, 2005
12:15 pm
197
LPC936 is fully pin-compatible with LPC935. As far as I know this is not documented. ... already ... <maciej.wiatr@b...> ... programming ... to be at ... ...
geejee_lpc
Offline Send Email
Dec 26, 2005
3:49 pm
198
Dear all, Ax51 CPU has bit control instruction that is CLR and SETB. LPC900 family have register are A,B,PSW,DPTR(DPH,DPL),SP,R0-R7*4 I confirmed the register...
yen0yuki
Offline Send Email
Dec 27, 2005
1:31 am
199
Hello Gertjan, Thanks for the tip. I will go through bridge code and will try to implement. I tried using 10k pullup on p0.4, p0.5 and p1.4(reset); it improved...
Hitesh Mahant
vital4all
Offline Send Email
Dec 27, 2005
1:35 am
202
... Dear yenOyuki, SETB/CLR opcode are suitable only in bit segment 20H-2FH and in SFR area for all address multiple of 8H ( eg. ACC B PSW Pn etc.) To...
ar_e_sys
Offline Send Email
Dec 30, 2005
9:00 pm
203
Gertjan, you wrote in your former mail that P05 and P06 were used... for LPC935 it is P04 and P05... I suppose you meant P04 and P05, right? Thanks, Maciej...
Dr. Maciej Wiatr
maciej_wiatr
Offline Send Email
Dec 31, 2005
11:59 am
204
You're right, P04 and P05 it is indeed. Sorry about that. ... LPC935...