243
Hi everybody, I´m a new LPC900´s user and i´ve got a little problem, When I use the T0 pin as a simple output pin to drive a load (on/off), The CPU stops ...
eletronica3
Offline Send Email
Mar 2, 2006
2:10 pm
244
Which LPC900 are you using. Larry Hi everybody, I´m a new LPC900´s user and i´ve got a little problem, When I use the T0 pin as a simple output pin to drive...
lgunseor@...
lgunseor
Offline Send Email
Mar 2, 2006
5:55 pm
245
Hi I´m using LPC935 lgunseor@... escreveu: Which LPC900 are you using. Larry SPONSORED LINKS Microcontrollers Microprocessor High performance...
Marcelo M Oliveira
eletronica3
Offline Send Email
Mar 3, 2006
1:43 am
246
... Intel microprocessors Pic microcontrollers ... Service. ... What mode are you using, 16-bit timer or 16-bit counter? Are you using the timer to toggle...
john
j_funk1425
Offline Send Email
Mar 3, 2006
6:00 am
247
It could be hardware or software. Look at the timer block diagrams in the user's manual. The Int0 pin can cause the timer to stop if the software is setup to...
Will
aplgoat
Offline Send Email
Mar 3, 2006
10:51 am
248
Hi, we started to post an FAQ. Some of these are a little tricky, so it might be worth to have a look. ...
philips_apps
Offline Send Email
Mar 10, 2006
1:46 am
249
Hello to everyone! I need help and/or suggestion to realize a smart load cell(classic wheatstone bridge) using an LPC917. The system needs 14 bits resolution...
gispul
Offline Send Email
Mar 13, 2006
10:16 am
250
Greetings to the group, i've already sent this to the Philips support, but i guess it isn't hurt to post it here also. There's something going on at the '931...
vesa_koli
Offline Send Email
Mar 13, 2006
2:31 pm
251
... Label: cpl P3.0 ;1 nop ;1 nop ;1 nop ;1 nop ;1 nop ;1 nop ;1 sjmp Label ;2 ... 9 cycles wek...
Jan Waclawek
wekovci
Offline Send Email
Mar 13, 2006
2:38 pm
252
... That's correct, 've been bit sloppy on my math:) Anyway, this gives CCLK frequency to be 3.75 MHz, which is an odd figure in this context. Vesa...
vesa_koli
Offline Send Email
Mar 13, 2006
7:16 pm
253
Dear ALL, I am using MCB900. When the program that I made was written, it was not possible to write it by ISP twice. I think, my program erased ISP code. So, I...
yen0yuki
Offline Send Email
Mar 14, 2006
2:15 am
254
... If you really have erased the ISP code then you have no option but to use a parallel programmer. Ian...
Ian bell
ruffrecords
Offline Send Email
Mar 14, 2006
9:13 am
255
... ICP won't work? wek...
Jan Waclawek
wekovci
Offline Send Email
Mar 14, 2006
10:21 am
256
... Hmmmm, and did you consider that the LPC9xx is a two-clocker? wek...
Jan Waclawek
wekovci
Offline Send Email
Mar 14, 2006
10:24 am
257
Dear Ian, Thank you for reply. ... How do I confirm it? Sample program is'nt <<< FYI >>> I wrote program by "FlashMagic" [Advanced option]-[security]-{Protect...
yen0yuki
Offline Send Email
Mar 15, 2006
1:18 am
258
... To be certain yes you need to try to load another program and run it. Also I had forgotten the 900 sereis has ICP as well as ISP. I am not sure what the...
Ian bell
ruffrecords
Offline Send Email
Mar 15, 2006
11:59 am
259
I am trying to set up the CCU in an LPC932 to output PWM. I have worked out most of it but there appears to be no information in the data sheet and user manual...
Ian bell
ruffrecords
Offline Send Email
Mar 15, 2006
12:00 pm
260
... ICP is a SPI-based ISP and is not dependent on the presence of the bootloader; whereas ISP is UART-based. wek...
Jan Waclawek
wekovci
Offline Send Email
Mar 15, 2006
4:33 pm
261
... Hi Jan, So maybe this chap can recover his part using ICP? Ian...
Ian bell
ruffrecords
Offline Send Email
Mar 15, 2006
7:03 pm
262
... Ian, Yes, ICP is meant to be an equivalent for the SPI-based ISP programming as it is known from PICs and AVRs and recently Atmel's 89Sxxx. It should work...
Jan Waclawek
wekovci
Offline Send Email
Mar 16, 2006
10:03 am
263
Dear JW, I have other programmer that is "PDS900" by Acqura. it has ICP function but I couldn't use. When it is used, The message is displayed. It is such a...
yen0yuki
Offline Send Email
Mar 17, 2006
12:42 am
264
... Well, that was somehow slipped off from my mind. Thank you very much for straighten things up. I had two erraneus incidents here: first i somehow forgot...
vesa_koli
Offline Send Email
Mar 18, 2006
1:45 pm
265
Hello there, ... Have you discussed this with the Acqura guys (who I have found very helpful)? either by email to their support desk or through their web based...
phb_miller
Offline Send Email
Mar 19, 2006
11:29 pm
266
... Available in source(!) form from the Philips website as code for appnote AN10337_1: Adding ISP firmware to an LPC900 software project Appnote at ...
Jan Waclawek
wekovci
Offline Send Email
Mar 20, 2006
8:01 am
269
Dear ALL, Thank you for your advices. My problem was as follows.ISP wasn't delete. It was very easy... 1)My program using external xtal. I didn't put external...
yen0yuki
Offline Send Email
Mar 23, 2006
10:36 am
270
... While I cannot help you with your real problem, can you please be more specific on this point? wek...
Jan Waclawek
wekovci
Offline Send Email
Mar 23, 2006
10:47 am
271
... more ... It was not working in high baud rate(=9600). When baud rate reduced to 7200,It was working. It was not sending "reset signal" maybe....
yen0yuki
Offline Send Email
Mar 24, 2006
1:10 am
272
Hi If you programmed the chip using the ISP protocol and if you need to put the values of the ISP registers back, you must use ICP protocol. Moreover, if you...
Omar Espinosa
opiedrahita2003
Offline Send Email
Mar 26, 2006
5:58 pm
273
Hi ! I build a lpc9xx programmer. The ISP mode it's fine, but I can't to program lpc915 with ICP mode. I downloaded the Bridge source code and recompiled with...
lopesjm_lpc
Offline Send Email
Mar 31, 2006
10:39 pm
275
Hi, Iam using the LPC935 and switch it to total power down modus to conserve battery power. DIVM=0 in my application. I am using the KBI interrupt to wake up...
geejee_lpc
Offline Send Email
Apr 10, 2006
6:12 pm