Search the web
Sign In
New User? Sign Up
lpc900_users
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Real people. Real stories. See how Yahoo! Groups impacts members worldwide.

Best of Y! Groups

   Check them out and nominate your group.
Having problems with message search? Fill out this form to ensure your group is one of the first to be migrated to the new message search system.

Messages

  Messages Help
Advanced
Messages 447 - 477 of 634   Oldest  |  < Older  |  Newer >  |  Newest
Messages: Simplify | Expand   (Group by Topic) Author Sort by Date ^
447
Hi -- I just joined this group and am looking for some feedback. A) To program (write programs for) the LPC9XX which compiler do you find better 1) SDCC or 2)...
Alvin Schmitt
schmitt_alvin
Offline Send Email
Oct 22, 2007
5:26 am
448
I used both, and I can say that depends on your knoledge an target: if you want to hava a free tool, you have to choose SDCC and will have also a lot of ather...
brginne69
Offline Send Email
Oct 22, 2007
7:40 am
449
Hi! The LPC935 has two DAC outputs. I thought it would be nice to use those DACs in a new design. I've done some testing with DAC and it works... well, in some...
geeliwan
Offline Send Email
Nov 6, 2007
10:31 am
450
... LPC935 DAC outputs are high-impedance, you shouldn't load those beyond 1M ohms. Regards, Gertjan...
geejee_lpc
Offline Send Email
Nov 6, 2007
7:00 pm
451
. . . ... . . . Hi! Thanks for your reply! It was a configuration problem. The digital output driver was still active. I wrote to the wrong register :-( It's...
geeliwan
Offline Send Email
Nov 7, 2007
11:30 am
452
Hi all! I need to know the MFGID, ID1 and ID2 for the new LPC954 device. I suppose that MFGID = 15H and ID1 = DDH, but ID2? Is there an updated...
Fausto Marzoli
faumarz
Offline Send Email
Nov 12, 2007
9:46 am
453
... I reply myself: ID2 = 7AH sometimes reading the manual helps... ;-) ... I reply myself here, too: 1K sectors. The ISP protocol has commands for 16 sectors...
Fausto Marzoli
faumarz
Offline Send Email
Nov 13, 2007
3:28 pm
454
For LPC954, the MFGID = 15H, ID1 = DDH and ID2 = 7AH. And sector size for LPC954 is 1K. Good Luck. Finn To: lpc900_users@yahoogroups.com From: faumarz@... ...
Finn Li
finn_li
Offline Send Email
Nov 14, 2007
2:18 am
455
Dear sir, I want to join lpc_900 group.presently i am working on lpc924 controller. I am facing problem during ISP programming.first time when i give supply...
chetan patel
chetan1317
Offline Send Email
Dec 5, 2007
6:07 am
456
i am facing problem in ISP programing in lpc924 controller.First time when i gave supply to controller in flash magic then it was automatic detact the...
chetan1317
Offline Send Email
Dec 5, 2007
6:43 am
457
Dear Chetan, First time you able to program becuase of Factory defualt ISP. At that time BSB bit is set from Factory. Once you program the Microcontroller...
Nilesh
inileshce
Offline Send Email
Dec 5, 2007
7:21 am
458
Thanks Nilesh for giving me very useful information. But in hardware activation method what type of haraware addition is required.please give me schematic of...
chetan patel
chetan1317
Offline Send Email
Dec 5, 2007
8:19 am
459
To activate ISP via HW, you have to choose DTR and RTS usage inside FLASH MAGIC settings. Hw side, you need an MCB900 board or you have to build an equivalent...
brginne69
Offline Send Email
Dec 5, 2007
8:53 am
460
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the lpc900_users group. File : /USB...
lpc900_users@yahoogro...
Send Email
Dec 12, 2007
3:55 pm
461
Hi, I have a problem with programming P89LPC922. I use ISP, i can programm it 1 time then i cannot programm it again. If i change the processor, i can programm...
goossensd
Offline Send Email
Dec 19, 2007
4:41 pm
462
Dear , You are able to program it first time becuase of Factory Programmed ISP setting.. I mean to say BSB (Boot Status Bit) = 1. Once you program it will be...
Nilesh
inileshce
Offline Send Email
Dec 19, 2007
4:56 pm
463
Dear Nilesh, Can I get a copy of your: Parallel port circuit.... And application software? Thank you very much, John W. Poore ________________________________ ...
Poore, John
poorejw
Offline Send Email
Dec 19, 2007
5:01 pm
464
... - You don't send a break on the serial port before starting ISP - You have not configured and activated in your firmware the serial port for break...
Fausto Marzoli
faumarz
Offline Send Email
Dec 19, 2007
5:02 pm
465
thanks all, it is a problem in my code. ... If...
goossensd
Offline Send Email
Dec 19, 2007
5:17 pm
466
Dear, I met the same problem when I used P89LPC932. The solution of the "1 time program" is to set BSB(Boot Status Bit). This problem will happen when you use...
Min Zheng
minming.zheng@...
Send Email
Dec 20, 2007
1:14 am
467
Dear Nilesh, Thanks for your advice....I have been using ICP method for the past some time and it works properly. ISP is somewhat limited, so either ICP or...
Navneet Vinaik
navneet_copper
Offline Send Email
Dec 21, 2007
6:30 pm
468
Hi, I want to design my own programming board for a LPC936 micro ( the postage and duty charges to get a ready board in India are outrages). I am more...
aquib fateh
aquibf
Offline Send Email
Jan 22, 2008
5:16 am
469
... postage and duty charges to get a ready board in India are outrages). ... with USB interface. ... Try it now. ... The ICP spec in the the "files section"...
lpc2100_fan
Offline Send Email
Jan 22, 2008
2:37 pm
470
Hi -- I am interested in obtaining the LPC9xx ICP Programmer and associated pdfs and code. From whom and how do I do this? Thank you. Alvin........
schmitt_alvin
Offline Send Email
Jan 22, 2008
11:23 pm
471
See the following URL for a USB programmer to ICP http://www.lpctools.com/index.asp?PageAction=VIEWPROD&ProdID=83 ... outrages). ... Mobile. ... board, ... ...
schmitt_alvin
Offline Send Email
Jan 23, 2008
4:51 am
472
There are several ICP options, one of which is available internationally from Digi-key; http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail?name=622- ...
markhuntsville
Offline Send Email
Jan 23, 2008
1:28 pm
473
for USB - check www.teamfdi.com ... postage and duty charges to get a ready board in India are outrages). ... with USB interface. ... Try it now. ... The ICP...
Nilesh
inileshce
Offline Send Email
Jan 24, 2008
8:46 am
475
Hi -- Is the P89LPC932A1 still in production? Any info would help. Thanks. Alvin... APSTRON P.O. Box 10336 Blacksburg VA 24060-1442 ...
Alvin Schmitt
schmitt_alvin
Offline Send Email
Feb 12, 2008
5:29 pm
476
yes Alvin Schmitt <schmitt_alvin@...> wrote: Hi -- Is the P89LPC932A1 still in production? Any info would help. Thanks. Alvin... APSTRON P.O....
Nilesh
inileshce
Offline Send Email
Feb 12, 2008
5:41 pm
477
I hav been working with the LPC935 for some time and would like to use the DAC0 output - But it would not work !! The reason was - I was using the MOD935 file...
Hans
oz4hz
Offline Send Email
Mar 7, 2008
1:52 pm
Messages 447 - 477 of 634   Oldest  |  < Older  |  Newer >  |  Newest
Advanced
Add to My Yahoo!      XML What's This?

Copyright © 2009 Yahoo! Inc. All rights reserved.
Privacy Policy - Terms of Service - Guidelines - Help