2202 john.mccool@... Send Email Dec 19, 2002
4:54 pm
I used to sell Jewelry, and we used steam cleaner to remove fingerpirnts and such. I am not sure if the heat would effect the reaction in the well, but it...
2201 Sanjaya Joshi
eosanj Send Email
Dec 19, 2002
4:08 pm
Buffing wheel setups from jewelry manufacture? (or you are talking about the inside bottom...) Best, Sanjay...
2200 Russ Leeker
scinomix2002 Send Email
Dec 19, 2002
4:07 pm
Michael, I had a similar problem. To resolve some of these issues I developed a static cling vinyl protector. The protectors worked great and protected the ...
2199 Neil Benn
neilbenn2000 Send Email
Dec 19, 2002
4:07 pm
Hello, When I have a problem like this I usually look at other industries to give me some ideas. You could try taking a look at areas such as mirror...
2198 Fabrice Turlais
fturlais Send Email
Dec 19, 2002
4:03 pm
Michael, I would think that if your entire assay was automated that should solve most of your problems or is it not possible ? Otherwise you could pass your...
2197 Michael Ouellette <...
norakbio Send Email
Dec 18, 2002
8:53 pm
LRIG Members, I have the task of automating or at least improving the end process of an assay that terminates in hand wiping the glass bottoms of each assay...
2196 Neil Benn
neilbenn2000 Send Email
Dec 17, 2002
7:43 pm
Hello, I have a project which requires the integration of a barcode scanner with our ABI 3700 sequencers. The 3700 currently does not have an integrated...
2195 John Brohan
jbrohan Send Email
Dec 16, 2002
7:18 pm
I once had to write a safety procedure for some software which was to be used in obstetrical wards, monitoring women in labour. We were trying to get FDA...
2194 kozikowski.ba@... Send Email Dec 16, 2002
6:27 pm
A recent LRIG thread discussed the utility of defining standard output formats from laboratory instruments (XML was mentioned). The Data Analysis & ...
2193 Oliver de Peyer
opeyer@... Send Email
Dec 16, 2002
6:25 pm
Dear Neil, Thanks for your suggestions. The Powers That Be have now put a lock on the door of the room, so that's a start (Now I can lock myself in for a good...
2192 David
robotics1nj Send Email
Dec 16, 2002
4:47 pm
Hi, Oliver Your safety officer might be wrong. The EU directive you need to see is The Supply of Machinery Regulations 1992 No 3073 Amendments 1994 No 2063 I...
2191 Neil Benn
neilbenn2000 Send Email
Dec 16, 2002
4:45 pm
Hello, Yes, the EU + UK directives can seem over the top. I usually look at taking sensible precautions on the machines. The best way to effectively improve...
2190 Oliver de Peyer
opeyer@... Send Email
Dec 16, 2002
3:26 pm
Dear David, Thanks for coming back to me. No, I haven't had any other replies. You're quite right of course, COSHH is not the main thing. In fact, COSHH is ...
2189 David
robotics1nj Send Email
Dec 16, 2002
2:53 pm
Hi, I didnt see any replies though you might have had some privately as requested. However I would just mention that this is not just a COSHH issue - the EU...
2188 Pankaj Oberoi
pankajoberoi... Send Email
Dec 11, 2002
4:23 pm
Joerg, My experiences with 1536 well plates is that they require some careful pipetting. You can get away with no having to spin plates by tracking the pipette...
2187 Oliver de Peyer
opeyer@... Send Email
Dec 10, 2002
4:23 pm
I am required to complete a safety assessment for my lab robot. Those of you who are based in the UK will be familiar with this as a COSHH assessment. My...
2186 joerg.dreessen@...
jdreessen2 Send Email
Dec 10, 2002
4:23 pm
Dear LRIG community, I'd like to ask if someone has experience with 1536MTP HTS assays with or without spinning the plate. As many fluorescence detectors are...
2185 briancwell@...
briancwell Send Email
Dec 7, 2002
2:27 pm
Eppendorf offers a automated centrifuge that can be accessed via a robotic arm. Brian Churchwell USA Scientific...
2184 Bob Mc Cafferty
biotica@... Send Email
Dec 6, 2002
3:19 am
Paul, You could try the Hettich distributor, ProScientific out of Connecticut or Jouan out of Winchester, Virginia. Both companies have automated centrifuges....
2183 Oliver De Peyer
opeyer@... Send Email
Dec 6, 2002
3:19 am
Dear all, Many thanks for the ongoing thoughtful suggestions & proposals that individuals and companies have sent to me. The more we discuss it the more steps...
2182 pmurphy@...
murfboston Send Email
Dec 6, 2002
3:18 am
Paul, Jouan robotics have a friendly automated centrifuge that will meet these requirements. Please feel free to contact me directly. Paul Murphy 617-413-9001 ...
2181 Chris Jennings
chrisjenning... Send Email
Dec 5, 2002
7:47 pm
Hi Paul, Velocity11 makes a automation friendly plate centrifuge that is capable of 3000rpm. It is robot accessible and has acceleration/deceleration times of...
2180 Kevin Keras
kevinkeras Send Email
Dec 5, 2002
7:47 pm
Paul, Velocity11 VSpin http://www.velocity11.com/products/vspin/product_info.html is spec'd at 3000RPM's. Sias Ixion http://www.sias.biz/Ixion.pdf is spec'd at...
2179 Paul Rodziewicz
prodziew@... Send Email
Dec 5, 2002
3:34 pm
One of our clients is looking for an automation friendly centrifuge for standard plates. Centrifuge must run at 3000 rpm for 15 minutes. Please contact me if...
2178 Oliver de Peyer
opeyer@... Send Email
Dec 5, 2002
3:34 pm
Again, many thanks for all those who have contacted me regarding this question. A company called CyBiosystems (SiBiosystems?) rang me but unfortunately their...
2177 Noga Yerushalmi
nyerushalmi Send Email
Dec 2, 2002
1:54 pm
Hi, Try the downloadable fonts from www.bizfonts.com we are using their code 39 and it works in excel, word and access. We print on stickers for culture plates...
2176 JAHall125@...
ncl1259790 Send Email
Dec 2, 2002
1:53 pm
PerkinElmer sells their own Wide bore tips. I recommend you contact them directly. Jefff MDM Diagnostics [Non-text portions of this message have been removed]...
2175 pedro perez pofenas
pofenas Send Email
Dec 2, 2002
1:53 pm
Hi Taylor... at first time, I believe you must to know what kind of Bar code are your instrument using (i.e. code 39, barcode, EAN.....). Sometimes, I've used...
2174 Ray Lombardi
raylsri Send Email
Dec 2, 2002
1:53 pm
A simple system for barcoding labels is available from a company named Brady. They have had systems for barcoding labels in other industries and have recently...
2173 lrig-discussion@yahoo... Send Email Dec 1, 2002
1:29 pm
The Laboratory Robotics Interest Group Discussion Mail List is for comments or questions about Laboratory Robotics and Automation. You receive messages...
Messages 2173 - 2202 of 6985   Newest  |  < Newer  |  Older >  |  Oldest
Add to My Yahoo!      XML What's This?

Copyright © 2010 Yahoo! Inc. All rights reserved.
Privacy Policy - Terms of Service - Guidelines NEW - Help