Search the web
Sign In
New User? Sign Up
lrig-discussion · LRIG Discussion Group is for comments or questions about Laboratory Robotics, or any Laboratory Automation topic.
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Real people. Real stories. See how Yahoo! Groups impacts members worldwide.

Best of Y! Groups

   Check them out and nominate your group.
Having problems with message search? Fill out this form to ensure your group is one of the first to be migrated to the new message search system.

Messages

  Messages Help
Advanced
Messages 2698 - 2727 of 6504   Oldest  |  < Older  |  Newer >  |  Newest
Messages: Simplify | Expand   (Group by Topic) Author Sort by Date ^
2698
The Laboratory Robotics Interest Group Discussion Mail List is for comments or questions about Laboratory Robotics and Automation. You receive messages...
lrig-discussion@yahoo...
Send Email
Jun 1, 2003
8:02 am
2699
I would like to know if any Biomek FX users perform their own in- house preventive maintenance on their Span-8 and Multichannel pods? For example, do you ever...
Ginger
grs3275
Online Now Send Email
Jun 2, 2003
7:29 pm
2700
Is there anyone running a Promega SV96 RNA kit on a Biomek FX who has seen their vacuum manifold crack in the back where it connects to the vacuum? If so, does...
Ginger
grs3275
Online Now Send Email
Jun 3, 2003
2:24 am
2701
Ginger, It's unusual for the manifold base to crack. The manifold is like any other piece of hardware, it should be regularly inspected and maintained. The...
Michael Bjerke
mbjerke@...
Send Email
Jun 3, 2003
7:11 pm
2702
BioTrove has just purchased a TekCel system for plate handling/storage of source and daughter plates. One of our collaborators will provide compounds in a low...
Tom Morrison
tbmorrison2003
Offline Send Email
Jun 3, 2003
7:11 pm
2703
We have seen a similar problem - our manifold has repeatedly cracked up at the top near the seal. So far, we have gone through at least four or five manifolds...
Brent Morse
BMorse@...
Send Email
Jun 4, 2003
12:26 am
2704
Dear list, I would need feedback for the use of Packard-PerkinElmer cell washer installed on the MiniTrack for cell based assay set-up. Is this device as good...
elepoul
Offline Send Email
Jun 4, 2003
1:07 pm
2705
Ginger, Have you considered using an automated centrifuge with the Biomek FX ? It will also reduce time and increase product retrieval. Paul Murphy Jouan...
pmurphy@...
murfboston
Offline Send Email
Jun 4, 2003
3:57 pm
2706
Anyone know a good source for a used FLIPR? -Mike ********************************************************************** This message is intended only for the...
Michael_Shanler@...
Send Email
Jun 4, 2003
5:09 pm
2707
Have you tried Molecular Devices? If it is not the latest version you are looking for, they may have some from trade-ins. Balazs ... From:...
Szoke, Balazs
balazsszoke
Offline Send Email
Jun 4, 2003
5:50 pm
2708
Hello everyone, Has anyone had any experience automating a crude photodocumentation station. We are currently using an Olympus digital camera and a Sony ...
mfell@...
markinator2000
Offline Send Email
Jun 5, 2003
1:39 am
2709
Not sure if you want to change hardware / software. Video cameras allow you to "grab" an image, filter / process the image, print it -- all under control of...
kebaldwin@...
Send Email
Jun 5, 2003
3:22 am
2710
Hi, I assume that you are using windows. There are many shareware and freeware programs available that are able to capture commands in a script type language....
G.J.W Euverink
G.J.W.Euverink@...
Send Email
Jun 5, 2003
2:39 pm
2711
A cry for help, except for the last line...! - Peter ... From: mfell@... [mailto:mfell@...] Sent: Wednesday, June 04, 2003 3:51 PM To:...
Peter Cohan
pcohan@...
Send Email
Jun 5, 2003
2:48 pm
2712
hi all ,we are looking for and automation spot cutter for our facility involved in proteomics, we hesitated to different kind of equipment which are basically...
frederic peyrard
frederic@...
Send Email
Jun 5, 2003
2:57 pm
2713
what are the filters and why do you use them. if all you need is a printed copy, use a digital camera - direct to photo printer combination. you should be...
david allen
dr01allen
Offline Send Email
Jun 5, 2003
2:59 pm
2714
Hi, Could any of you provide the name of the manufacturer of those magnetic stirrers/beads that can fit into 96 or 384 well plates? I have seen their booth at...
Ima Bantoot
Imalda@...
Send Email
Jun 6, 2003
12:48 am
2715
Ima, That would be: Dr. Patrick Cleveland President V&P Scientific Inc. Work: 858-455-0643 Fax: 619-455-0703 E-Mail: pcleveland@... 9823...
Andy Zaayenga
andy_zaayenga
Offline Send Email
Jun 6, 2003
12:53 am
2716
It is V&P Scientific 9823 Pacific Heights Blvd, Ste T San Diego, CA 92121 Phone (800) 455-0644 pcleveland@... http://www.vp-scientific.com ...
Fred Spike
fred@...
Send Email
Jun 6, 2003
12:54 pm
2717
Having worked extensively with the Beckman Coulter vacuum manifold in the past I have a few insights. Cracking of the base usually occurs, due to the tapered...
Jeff Cahlik
jcahlik@...
Send Email
Jun 6, 2003
7:08 pm
2718
Dear Frederic, You might like to add gelPix from Genetix to your list for consideration. Further information is on the web site www.genetix.com Best wishes ...
Sarah Stephens
genetixsarah
Offline Send Email
Jun 6, 2003
7:08 pm
2719
Sorry the body of the message was not included ! We can help with our OVERLORD product. Regards Malcolm Crook Process Analysis & Automation UK +44 1252 373000 ...
MJCatPAA@...
Send Email
Jun 6, 2003
7:09 pm
2720
Dear Frederic, In addition to the spot cutters mentioned you may wish to consider the 2D iD from LEAP Technologies. You can view literature and information on...
Gordon Nye
gnye@...
Send Email
Jun 6, 2003
7:09 pm
2721
TOMTEC has a 3 flea stirrer. www.tomtec.com [Non-text portions of this message have been removed]...
bwilliamson@...
rlwilliamson...
Offline Send Email
Jun 6, 2003
11:35 pm
2722
Hello, I'm investigating the use of automatically gathered process metrics with the drug discovery process. Therefore I'm doing some web-based research. I...
Neil Benn
neilbenn2000
Offline Send Email
Jun 9, 2003
4:16 pm
2723
Has anyone had much luck pipetting resins? I need an instrument for dispensing 100-200uL of slurry (the resin size will vary) into 96-well deepwell plates....
Michael_Shanler@...
Send Email
Jun 9, 2003
5:05 pm
2724
Hi Neil, Statistical Process Control (SPC) is a QC and manufacturing control method used to improve production efficiency. It is not industry or process...
Mike Theran
mtheran@...
Send Email
Jun 9, 2003
6:55 pm
2725
Mike, If the slurry isn't too viscous, a biomek 2000 should be able to handle the task. The pipetting feature is equiped with a mix function that can stir up ...
Michael Chiarcos
malachi_xx
Offline Send Email
Jun 9, 2003
6:55 pm
2726
Mike, Two stories that may help: One, in bulk dispensing a large volume of slurry with similar [x] requirements, we developed an "in-line" method of agitation...
Jeffrey Walter
jw35739
Offline Send Email
Jun 9, 2003
6:55 pm
2727
Neil, My background includes many years in electronic circuit board manufacturing, semiconductor production and general factory automation. These industries...
Kevin Keras
kevinkeras
Offline Send Email
Jun 9, 2003
6:55 pm
Messages 2698 - 2727 of 6504   Oldest  |  < Older  |  Newer >  |  Newest
Advanced
Add to My Yahoo!      XML What's This?

Copyright © 2009 Yahoo! Inc. All rights reserved.
Privacy Policy - Terms of Service - Guidelines - Help