Messages: Simplify | Expand Author Sort by Date ^
3595 lrig-discussion@yahoo... Send Email May 1, 2004
9:21 am
The Laboratory Robotics Interest Group Discussion Mail List is for comments or questions about Laboratory Robotics and Automation. You receive messages...
3596 ezra_at_matrix Send Email May 6, 2004
6:22 pm
I have tested the tubing used in our Wellmate (an 8 channel dispenser with a low cost tubing cartridge) and, at least in my hands, the tubing seems to be...
3597 John Thomas Bradshaw
JBradshaw@... Send Email
May 6, 2004
6:22 pm
Hello All, I am trying to get a feel for the most commonly used terminology regarding the performance specifications of liquid handlers. For a measure of the...
3598 Joseph Suzow
jsuzow Send Email
May 6, 2004
6:23 pm
Xavier Thanks for the reply. You may be just the person I'm looking for. Here are the primary questions I need to answer for my report: 1) Can I output data...
3599 Ed Oto
edoto2001 Send Email
May 6, 2004
9:35 pm
Hi Joseph,, See input in field. Can't answer all of them, but I hope this helps. Also, any good sales rep should be able to give you a quick course on what...
3600 lvburling@... Send Email May 6, 2004
10:31 pm
Hi: In obtaining approval for FDA regulated ASSAYS, the terms that must be used are: accuracy precision (or %CV) It should be true for Pharma as well. Lillian...
3601 G. S. Hudson
gshudson@... Send Email
May 6, 2004
10:31 pm
Hi Ed, Who uses a diode in their fluorometer? By the way, you are correct that most analog-type fluorometers are "current averaging." GSH ... [Non-text...
3602 Mark Wingerd
mwingerd Send Email
May 6, 2004
10:34 pm
De-salting plates for Serum, and use on a Tecan Robot. We are looking De-salting plates for Serum, and use on a Tecan Robot. The current plates do not seal...
3603 Mike Benway
mbenway Send Email
May 7, 2004
2:02 pm
So, under those FDA regulations how is accuracy calculated? If it is (Observed/Expected)*100% this creates the akward scenario in which accuracy can be...
3604 Tony Chalkly
tonychalkly Send Email
May 7, 2004
2:02 pm
This is interesting. Pedantically one is measuring inaccuracy and imprecision. Take the formula (100*(mean - target)/target) and add some artificial numbers...
3605 Tony Chalkly
tonychalkly Send Email
May 7, 2004
3:17 pm
Mike, I am sorry that your question ... Can you tell us what FDA technically means by accuracy? ... is too technical for me to answer, but as I said in my...
3606 Ed Oto
edoto2001 Send Email
May 7, 2004
3:17 pm
HI GS, Sorry about that, I was thinking about the detectors in a reader I used to sell and it had a diode in it, but for photometry. Ed ... From: G. S. Hudson...
3607 Ed Oto
edoto2001 Send Email
May 7, 2004
3:18 pm
Sounds like you're using a gripper to move the plates and placing them on a vacuum block. You'll need to press the plate down with the gripper with vacuum on....
3608 John Thomas Bradshaw
JBradshaw@... Send Email
May 7, 2004
8:26 pm
Thanks all for the responses. For the record, let me clarify one point that was sagely brought up by Tony. The relation that I defined for the deviation of...
3609 Tom Strader
ts_8675309 Send Email
May 7, 2004
8:26 pm
Hi John (and everyone else): Here's a link to a good overview right from the FDA's website: Go to www.fda.gov/ohrms/dockets, then do a search on " accuracy ...
3610 Griesmayr, Gottfried
gottfried.griesmayr@... Send Email
May 10, 2004
12:33 pm
Hi John, Accuracy and Precision are recurrent discussion issues because of different interpretations in different application areas of the terminology ...
3611 prodziew Send Email May 10, 2004
12:33 pm
I am looking for an automated dispenser to dispense 2mg of dry powder into an HPLC sample vial. Subsequently we need to add liquid to the same vial. I am also...
3612 Peter D Edwards
Peter.Edwards@... Send Email
May 10, 2004
3:28 pm
Paul, You might try the Swiss company, Chemspeed. I know they produce an automated dispenser for powders that has mg accuracy. regards Peter Edwards Peter...
3613 John Thomas Bradshaw
JBradshaw@... Send Email
May 10, 2004
5:36 pm
I believe Transform Pharmaceuticals does something like this. At least I saw them present a poster on delivering samples other than liquid. John Thomas...
3614 Cameron, Gregg
gdc2000 Send Email
May 10, 2004
5:49 pm
Paul, Also, Zinsser (http://www.zinsser-analytic.com/company.asp). Look for LIPOS and CALLI products... Gregg Cameron Sr. Research Assoc. Abgenix Biopharma ...
3615 Ilya Feygin
finagain2001 Send Email
May 11, 2004
4:29 am
I am looking for an automated dispenser to dispense 2mg of dry powder into an HPLC sample vial. Subsequently we need to add liquid to the same vial. Paul, We...
3616 prodziew Send Email May 11, 2004
4:29 am
Hi, Has anybody integrated Wallac System 1445 mass spectrometer from MDS Sciex in their automated system? I am looking for information on how to control the...
3617 Mark Wingerd
mwingerd Send Email
May 11, 2004
10:30 am
All, Have you seen any good programs, or VB Components, or web-based Components (!!) to build a good lab scheduling program? Preferably a LC/MS Lab ?? See:...
3618 joerg.dreessen@...
jdreessen2 Send Email
May 11, 2004
10:32 am
Paul, You might try to contact SYSMELEC in Switzerland. We developed with them recently a fully automated powder weighing system for high throughput screening...
3619 Fermier, Adam [PRDUS]
afermier@... Send Email
May 11, 2004
9:56 pm
Hello Paul, We currently use an Autodose Powdernium to do exactly what you are asking to achieve. We add ~ 1 mg of powder to each vial then use a Gilson 215...
3620 j_maturana Send Email May 11, 2004
9:59 pm
I am not sure if this is the right forum, if not please guide me where I could forward this kind of questions. I was wondering if somebody can give me some...
3621 GRAY (James Gray)
grayj@... Send Email
May 12, 2004
4:31 pm
Jaime, for lightweight (read: inexpensive) applications the following article mentions many (even though it focuses on Stattools). I've used IDBS's XLfit a...
3622 jfollen1 Send Email May 12, 2004
4:31 pm
Does anyone have a 1536 plate filler/rapid dispenser? If so, how is it working and in what applications is it being used, i.e. cell- bassed assays, protein,...
3623 ces1tom@... Send Email May 12, 2004
4:32 pm
Through Strand Genomics I can provide Data analysis and mining software. Please contact me for details. Tom Hill Cutting Edge Scientific (301)596-1840 ...
3624 Neil Benn
neil_david_b... Send Email
May 12, 2004
4:32 pm
Hello, With 2000 data points you have a relatively low amount of data compared to what people are normally looking at in fields such as high throughput...