Messages: Simplify | Expand Author Sort by Date ^
6045 Jobling, Michael
Michael.Jobling@... Send Email
May 16, 2008
12:52 am
Hi all, I wondering if anybody has experience with Peltier-type heat/cooling blocks that easily fit on a Biomek FX deck. We'll be exploring all options, and so...
6046 Gregory Lowe
gdjlowe Send Email
May 16, 2008
12:53 am
Also to answer my own question. We are here to help each other and solve the issues that we face today. We need as a group to force the manufacturers to step...
6047 David
robotics1nj Send Email
May 16, 2008
12:54 am
Hi Ray, Forgive the grumbles of an old engineer. I do have a nasty habit of spotting generalizations and needing to challenge them. Even if this entire subject...
6048 GregoryRRyan Send Email May 16, 2008
5:56 am
... umm, I for one, am pretty interested in this thread, so don't stop cause of me listening in the corner. does it matter if there is no 6 axis universal...
6049 Mike Counsell
mcounsell0 Send Email
May 16, 2008
2:54 pm
You make a couple of very good points here regarding software architectures that I agree strongly with. With the correct abstraction layers (interfaces) it...
6050 David
robotics1nj Send Email
May 16, 2008
2:54 pm
Actually you've raised a good point. Maybe the two threads are related. I think the open software idea concerns lab automation in general. So how does it...
6051 David Ley
david.ley@... Send Email
May 16, 2008
2:54 pm
Michael I apologise for being commercial, we have a wide range of peltier type heating, cooling and shaking ancillaries, see the following link. ...
6052 Greg
gdjlowe Send Email
May 16, 2008
2:55 pm
No you are on the right thread. It doesn't matter as long as you have an abstraction layer and that can be universal. Sent from my BlackBerry. ... From:...
6053 Raymond Hui
fastgeometry Send Email
May 16, 2008
2:55 pm
G, There are robot controllers (and an increasing number of them) which allows programming in the Windows environment. In some cases, this is ActiveX based but...
6054 Raymond Hui
fastgeometry Send Email
May 16, 2008
2:55 pm
We have previously integrated a thermal cycler on the FX. I think this has been done by various people. If you do a thorough literature search, you should be...
6055 Nygaard, John
jgnygaard Send Email
May 17, 2008
6:53 am
Hi Micheal, I've used the Beckman Peltier ALP for almost two years now on my FXs and it works very well. We use it primarily @ 4°C for the more unstable...
6056 jonnewmansmith Send Email May 17, 2008
6:55 am
I have been reading this thread with interest so i thought i would throw in my two pence worth. A lot of the discussion is of people experiences with older...
6057 Gregory Lowe
gdjlowe Send Email
May 17, 2008
6:56 am
Seems that some of you believe I was taking a shot at CRS so let me clarify as it was far from it. The effort taken to write an instrument server so that it is...
6058 Gregory Lowe
gdjlowe Send Email
May 17, 2008
6:56 am
And more to that if you would like. Contact me anytime offline. There were many instruments that have software which were unfriendly to automation. Speaks to...
6059 Ikeda, Timothy
tpi3004 Send Email
May 17, 2008
6:59 am
Ray writes: "As far as I know, Protedyne is the only company that is marketing a SCARA robot explicitly for lab use. If anyone can think of others, please let...
6060 David
robotics1nj Send Email
May 17, 2008
4:56 pm
... I'm sure Ray knows this but for the benefit of any members who don't know SCARA stands for Selective Compliance Assembly or Articulated Robot Arm....
6061 Ian Yates
iwyates Send Email
May 20, 2008
5:03 am
... format where the ... At Velocity11 we use a high-speed 3-axis radial robot (with industrial reliability and robustness characteristics) that sounds akin to...
6062 Hansen, John [VRCBE]
jhansen2@... Send Email
May 20, 2008
5:04 am
Hi David, Thanks for being commercial. It pleases me to see that there are alternatives to what the instrument vendors offers. My current need is slightly...
6063 Gregory Lowe
gdjlowe Send Email
May 20, 2008
5:04 am
http://en.wikipedia.org/wiki/Good_Manufacturing_Practice http://en.wikipedia.org/wiki/DeviceNet Automotive changes their lines every year to accommodate new...
6064 Marc
searcher_21044 Send Email
May 20, 2008
5:04 am
(Disclaimer... I'm the Biomek product manager from Beckman Coulter. I'll respect the group by sticking to the facts with a minimum of marketing spin!) For...
6065 victoria_macomber@...
victoria_mac... Send Email
May 20, 2008
11:42 am
Sorry for forgetting but who acquired Protedyne? Thanks, Vikki Sent via BlackBerry by AT&T ... From: "Ian Yates" <iyates@...> Date: Sun, 18 May...
6066 victoria_macomber@...
victoria_mac... Send Email
May 20, 2008
11:42 am
Hi John, have you looked into Mecour for your cooling needs? I know they are customized and may be able to help. Cheers, Vikki Sent via BlackBerry by AT&T ......
6067 Andy Zaayenga
andy_zaayenga Send Email
May 20, 2008
12:11 pm
In May 2007, Protedyne became a wholly owned subsidiary of Laboratory Corporation of America www.labcorp.com. - Andy...
6068 Tom Wright, T-US
tom.wright@... Send Email
May 20, 2008
5:50 pm
Hi John - Fair warning; I work for Tecan's customization group, and our engineers just love this stuff... Our sales & apps staff typically use Tecan's...
6069 Tom Wright, T-US
tom.wright@... Send Email
May 20, 2008
5:51 pm
...by the way, if we do write up specs for something custom, English would be preferable. Was I the only one who needed Google to figure out that Ærbødigst...
6070 Hansen, John [VRCBE]
jhansen2@... Send Email
May 21, 2008
10:28 am
Hi Tom, I see that you understand the problem: The POSID moves a rack with the plates over a distance of about 30cm while it scans the barcodes. Any cabling or...
6071 Walter Schick
wschick65 Send Email
May 22, 2008
1:13 pm
Hi, BioTX Automation had the same customer problem, in that preparing a few microliters of PCR reactions resulted in evaporation losses. They have a ice-bath...
6072 kasiapaczyna Send Email May 27, 2008
5:43 am
Hello, New Tetra+ with Aequorin option has the same sensitivity in Fluorescence as the Standard camera, but it provides 6.9 logs of detection in Luminescence,...
6073 Kevin K. Olsen
olsenkevink Send Email
Jun 1, 2008
4:23 am
We have a faculty member here who is thinking about buying some BioTek microplate readers for his lab. Does anyone have anything good or bad to say about these...
6074 McCloud@...
mccloud50723 Send Email
Jun 1, 2008
4:23 am
... We have purchased cardboard boxes which are subdivided into the standard 8 x 12 grid, and are used for storage of the Corning 430663, a 5ml screw top vial,...