6266 lrig-discussion@yahoo... Send Email Dec 1, 2008
8:38 am
The Laboratory Robotics Interest Group Discussion Group is for comments or questions about Laboratory Robotics and Automation. You receive messages posted to...
6267 mark ollmann
mark_r_ollmann Send Email
Dec 2, 2008
12:00 am
Does anybody so something similar? I found the most I could dispense was 2-3uL, otherwise the drop was too big and flooded the top of the plate. I could...
6268 jgnygaard Send Email Dec 2, 2008
4:39 am
Has anyone used, or does anyone know, where I might be able to find slightly wider-bore tips for use on the Biomek FX 384-channel head (similar to the Beckman...
6269 Mark Ollmann
mark_r_ollmann Send Email
Dec 3, 2008
5:57 am
The Title got cut off, should have included that I am working with a Flexdrop for PU, I mean PE. [Non-text portions of this message have been removed]...
6270 Kevin Keras
kevin_keras Send Email
Dec 3, 2008
5:58 am
Hi John, Phenix Research (www.phenixresearch.com) has 96 channel wide bore tips for the FX, and they also have extended reach tips that increase the volume...
6271 Matt Bristow
psych152 Send Email
Dec 3, 2008
6:21 am
Hi, I posted here in November with some systematic colour changes in an automated ELISA. We're pretty new to automated ELISA and I now wondering if systematic...
6272 Neil Benn
neil.benn@... Send Email
Dec 3, 2008
4:23 pm
Hello, It should not be an effect of automated per se - I assume that you are doing manual ELISAs and that doesn't show the same issue? Try doing a manual...
6273 mbenway Send Email Dec 3, 2008
4:24 pm
Hi Matt, Sorry to hear about your troubles. I can say that, no, systematic errors are not a permanent feature of automated ELISA assays, but they are...
6274 Tom Wright, T-US
tom.wright@... Send Email
Dec 3, 2008
4:25 pm
Hi Matt - Sounds like a timing gradient to me. Consistent ELISA results require all plate wells to be handled as identically as possible, not just in liquid...
6275 Gernot J Abel
g7gja Send Email
Dec 8, 2008
3:18 pm
I want to readout the values from the pressure sensors on the 1 ml channels of a Hamilton Starlet after an aspirate step. I know how to do this from the...
6276 aokun2003 Send Email Dec 9, 2008
3:46 am
I wanted to find out if anyone knows anything about Cerionx, Inc. and their plasma tip cleaner? I tried calling the number on their website (www.cerionx.com)...
6277 Wendy Lauber, T-CH
augustasibes Send Email
Dec 9, 2008
3:54 pm
Hello, Cerionx has gone out of business but Tecan does have units available. If you would like to discuss if your application needs would be satisfied by the...
6278 Neil Benn
neil.benn@... Send Email
Dec 9, 2008
3:56 pm
Hello, This is a bit off topic but I hope someone can help - a company I used to work in a long time ago gave a course which was entitled something like 'IT...
6279 michael.brehm Send Email Dec 9, 2008
3:56 pm
Hello, does anyone have experience with the Synergy2 plate reader. We are planning in upgrading our plate reader. As a option the Biotek reader came up. I only...
6280 David Glass
david.glass@... Send Email
Dec 11, 2008
6:11 am
A few of the classics... Peopleware: Productive Projects and Teams ISBN: 0932633439 Facts and Fallacies of Software Engineering ISBN: 0321117425 The Mythical...
6281 lrig-discussion@yahoo... Send Email Jan 1, 2009
8:31 am
The Laboratory Robotics Interest Group Discussion Group is for comments or questions about Laboratory Robotics and Automation. You receive messages posted to...
6282 trmadr Send Email Jan 7, 2009
6:48 pm
Hi everyone, I am trying to get a sense of the prevalence of HTS amenable qPCR machines in core screening groups in both the academic and industry setting. My...
6283 Marc Feiglin, T-US
feiglinm Send Email
Jan 7, 2009
8:36 pm
Dan, I know of at least two HTS amenable qPCR instruments: the AppliedBio 7900 and the Roche LightCycler 480. We have integrated both of these units with our...
6284 jliscouski Send Email Jan 8, 2009
10:11 pm
This Spring the JALA will include an article by Neil Benn and myself on a "Discussion of Open Source Methodologies in Laboratory Automation". As part of that...
6285 Agnieszka Lichanska
inez_garfield Send Email
Jan 9, 2009
5:18 am
Hi Dan, There are quite a few qPCR HTS amenable instruments, obviously ABI 7900, Roche Lightcycler, Corbett real time instrument, also BioRad realtime MJ...
6286 Robert Keefe
tgi_rtp Send Email
Jan 9, 2009
3:39 pm
Dan, There is a relatively high throughput qPCR platform developed a few years ago by BioTrove (http://www.biotrove.com/index.html) that uses established...
6287 G. S. Hudson
gshudson@... Send Email
Jan 9, 2009
3:40 pm
Thanks. Care to weigh-in on ABI / Invitrogen / Life Tech? I hear the new company, "Life Tech," bought all the best technologies in the industry, and...
6288 Andy Zaayenga
andy_zaayenga Send Email
Jan 13, 2009
2:40 am
The Association for Laboratory Automation (ALA) and the Laboratory Robotics Interest Group (LRIG) are excited to announce the 15 companies who will present in...
6289 Ian McFarlane
cambridgecor... Send Email
Jan 15, 2009
11:40 pm
It depends on what you mean by HTS. Almost all qPCR (and plain-old PCR) machines are 96- or 384-well format as standard (only recently have 'personal&#39; 24- and...
6290 greg.dummer Send Email Jan 16, 2009
8:47 pm
Thanks for mentioning LabAutomation2009 Andy. Just a quick note. I'm just out of a meeting with our Career Center team. At present we will be posting 110...
6291 lrig-discussion@yahoo... Send Email Feb 1, 2009
8:24 am
The Laboratory Robotics Interest Group Discussion Group is for comments or questions about Laboratory Robotics and Automation. You receive messages posted to...
6292 donwljr Send Email Feb 7, 2009
3:10 pm
Hello i have a question concerning aliquotting a 15 ul rxn into a 384 well via 3 x 5 ul aliquots: i'm having a problem keeping the reagants in the well. in...
6293 Eric Nordby
ecnordby64 Send Email
Feb 8, 2009
1:04 am
Don, Could you include a few more details on what you are trying to do. What liquid type is it, how viscous, coming from what (96 or reservoir), what kind of...
6294 Reed Hokanson
rhokan1053 Send Email
Feb 9, 2009
4:28 pm
Hello, A bit off the subject, but do any of the service groups that monitor LRIG use an "Off the Shelf" Field Service Software? We are investigating...
6295 Andy Zaayenga
andy.zaayenga@... Send Email
Feb 9, 2009
5:01 pm
Hi Reed, I had some experience with Tigerpaw, www.tigerpawsoftware.com <http://www.tigerpawsoftware.com/> , circa 2002. It was a basic off the shelf package...