RE: [m1oasys] Warning on BYO Limit Switch

could possiby been the wedge or the limit switch itself somehow loosened up.  Scott is aware and is investigating.  In the mean time I would suggest checking your limit switch to ensure the screws are tight and the wires are snug. 

Christopher Abissi <cabissi@...> wrote:
Chris,
Do we know anything more about the failure? Did it simply fail or did the magnet or sensor become dislodged?
Chris A.

From: m1oasys@yahoogroups.com [mailto:m1oasys@yahoogroups.com] On Behalf Of Chris Hetlage
Sent: Friday, November 30, 2007 11:51 PM
To: m1oasys@yahoogroups.com
Subject: [m1oasys] Warning on BYO Limit Switch
I got a report from a BYO owner this evening that the limit switch on
his BYO motor system failed and the roof crashed into his motor
assembly, causing some damage to his south wall. He does not have an
m1OASYS and fortunately was manually operating the roof at the time
of the crash so he could stop it in time to prevent it from coming
off the rack.

I highly recommend setting the m1OASYS open/close relay timing rules
to exactly the amount of time needed to open and close your roof, no
more then needed. This is contrary to what many have done, including
myself...relying on the BYO limit sw alone is probably not a good
idea, especially for a remote operation.

Perhaps someone who is at their observatory this weekend can work on
a rule to additionally turn the relay off once the roof open or roof
close sensor turns to a secure state. This will add an extra layer
of protection. I think this will work but will need some testing and
unfortunately I am unavailable for a few weeks.

A rule something like this should work;

WHENEVER Roof Stat Opened (Zn 11) BECOMES SECURE
THEN TURN Open Roof SW (Out 9) OFF

WHENEVER Roof Stat Closed (Zn 12) BECOMES SECURE
THEN TURN Open Roof SW (Out 10) OFF

This rule should only activate when the sensor actually triggers
closed, indicating the roof has reached an open or closed position.

Three layers of protection is always a good idea, 1-BYO Limit Switch,
2-Motor Relay Timing, 3-Roof Sensor Rule

I'll be traveling tomorrow but feel free to call my cell if you need
further assistance.

Regards,
Chris Hetlage
816-885-3420

__________ NOD32 2696 (20071130) Information __________

This message was checked by NOD32 antivirus system.
http://www.eset.com



Mon Dec 3, 2007 3:47 am

chrishet55
Offline Offline
Send Email Send Email

Forward
Message #24 of 190 |
Expand Messages Author Sort by Date

I got a report from a BYO owner this evening that the limit switch on his BYO motor system failed and the roof crashed into his motor assembly, causing some...
Chris Hetlage
chrishet55
Offline Send Email
Dec 1, 2007
4:51 am

... that should be: THEN TURN Close Roof SW (Out 10) OFF Dave...
ve3gyq
Offline Send Email
Dec 1, 2007
9:15 pm

... And I should have pointed out that we could add those rules to the ones that send the messages when the roof is opened or closed ... i.e. a rule exists to...
ve3gyq
Offline Send Email
Dec 1, 2007
9:25 pm

Chris, Do we know anything more about the failure? Did it simply fail or did the magnet or sensor become dislodged? Chris A. _____ From:...
Christopher Abissi
cja2173
Offline Send Email
Dec 3, 2007
2:13 am

could possiby been the wedge or the limit switch itself somehow loosened up. Scott is aware and is investigating. In the mean time I would suggest checking...
Chris Hetlage
chrishet55
Offline Send Email
Dec 3, 2007
3:47 am

Hi Chris A., The initial finding is that Frank's motor was installed in January 2007, just before we started using locktite on the small nuts that hold the...
horstmd_di
Offline Send Email
Dec 3, 2007
7:24 pm

Sounds like some locktite might be in order for mine as well, built before Franks. Thanks for the tip Scott, and let us know when you get those preventive...
Chris Hetlage
chrishet55
Offline Send Email
Dec 4, 2007
3:36 am

Hi Chris. Be sure to follow the recommendations posted in the files in the BYO group. You can paste them over here too if you want. Happy Holidays all! Scott ...
horstmd_di
Offline Send Email
Dec 10, 2007
4:58 pm

Hi Folks, I just uploaded the document Scott wrote up on the motor/switch maintenance. Thanks Scott! ... built ... you ... one ... to ... 100,000+ ... roof ...
Chris Hetlage
chrishet55
Offline Send Email
Dec 10, 2007
9:03 pm

Chris, I think that a lot of us would be greatly appreciative if the maintenance instructions included clear pictures of what the various things to me...
cja2173
Offline Send Email
Jan 2, 2008
3:17 am

Hi Chris. Do the pics in the maintenence file not open for you? The instructions should be pretty clear if they do. I didn't post any pics on the roller system...
horstmd_di
Offline Send Email
Jan 2, 2008
4:45 pm

Scott, Happy New Year to you and Dianne and your family! I didn't notice the pictures below at first. Now that I look, the text in blue overlying the black...
cabissi@...
cja2173
Offline Send Email
Jan 2, 2008
5:58 pm