Chris, I think that a lot of us would be greatly appreciative if the maintenance instructions included clear pictures of what the various things to me...
Hi Chris. Do the pics in the maintenence file not open for you? The instructions should be pretty clear if they do. I didn't post any pics on the roller system...
Scott, Happy New Year to you and Dianne and your family! I didn't notice the pictures below at first. Now that I look, the text in blue overlying the black...
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the m1oasys group. File :...
m1oasys@yahoogroups.com
Jan 17, 2008 2:46 am
39
... I completed an AutomaDome DLL to control the M1 OASYS roof system ... you do not need ASCOM for this, of course, but you would need AutomaDome from...
Very cool! Nice work Dave, Thanks! ... I completed an AutomaDome DLL to control the M1 OASYS roof system ... you do not need ASCOM for this, of course, but...
... On a new topic: I logon via phone and go in to Automation and it says to check roof sensor and open roof, press 1 (on my phone) but it never seems to open....
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the m1oasys group. File :...
m1oasys@yahoogroups.com
Jan 17, 2008 11:44 pm
45
... I uploaded a slightly updated version of the DLL that ignores a request to connect when you are already connected. Previously, if you tried to connect thru...
Chris Abissi solved the issue some have seen on the XEP setup whereby emails/text messages are not being sent. Chris has discovered that if you need to use...
Chuck has updated the m1Live ASCOM driver to include a Vista setup, updated to ASCOM v5, as well as resolving a few other issues reported, including one issue...
... Are you saying that if you want to use the "name" for your mail machine, like pop3.mymail.com, instead of a xxx.xxx.xxx.xxx address, that you set the...
Chris-Can you clarify your message-it may have gotten garbled? Did you mean we should trying using our ISP's DNS IP address instead of our mail server's IP...
David, you should try this on one of your network computer. open a command line interface <Run CMD> and type "ipconfig /all" Look at what it tells you is the...
I'm not a network guru, but I play one on TV...lol...I suspect what is going on is the DNS client, that the XEP product is using, is not very robust. When we...
Hi Dave, I think my previous msg may have answered this...however you do not define POP servers in the XEP as these are for incoming mail services...typically...
... That may be true for some folks but my ingoing AND outgoing server is pop3.wcoil.com It uses authentication I believe so I may have problems I have the...
Dave, There are 2 fields on the right side of the same screen that allow you to put in the User Name and password. I think there is a checkbox for mandating ...
One item in my automation process that had been an insurmountable obstacle was just conquered, automating the control of my Pier Tech 3 motorized pier. This...
... Yes, I got worried for nothing ... Yes, I put in the Username and Password to authenticate, but left the other box UNchecked since I do not need to log...
Hi Folks, Chuck and I are discussing ideas for the next version of the ASCOM driver and we are wondering what things you would like to see in it. Tighter...
Hi, I'm a newbie to roll-off-roof automation. I need to know the correct configuration of the BYO motor interface to Output 3 on the Elk controller. I am...
... Chris: what what would you really need? The driver opens the roof. The image control programs simply issue a command to the roof controller to open and...
... If you have the instructions that Chris sends out with the M1OASYS then look at page 5 .... You have three wires from the BYO interface: 1) a common 2)...
Just go to the files section in this group and download the pdf of the schematic of the hook-up. It is very straight-forward if you follow my diagram. Norm ...
... And, Don from BYO told me on the phone that he labelled the wires so he should have no problem when he looks at your PDF. I did remember that I had to...
perhaps you are correct...just thought I would ask...are you sure you don't want a 'cook the coffee' option at the end of each imaging run??? lol..... ... the ...