753
Hi, I have a problem with NMRPipe. I have to suppress more than one signal in a DQF-Cosy spectrum, I have suppressed the solvent signal but I'm not able to...
marinmrpipe
Offline Send Email
Oct 5, 2004
10:47 am
754
Many greetings. It's possible to supress more than one signal region by a series of first-order time domain corrections, each of which corresponds to a shift...
Frank Delaglio
bigfdelaglio
Offline Send Email
Oct 5, 2004
3:13 pm
755
Dear all, I have five 2D spectra measured under identical conditions except that they have slightly different transmitter offsets. When I try to use ...
Jerry Chan
gelberjerry
Offline Send Email
Oct 11, 2004
10:53 am
756
... maybe shifting each spectrum so that the chemical shift windows correspond again ... the "FSH" shifting command can be used to shift the spectrum by a...
Frank Delaglio
bigfdelaglio
Offline Send Email
Oct 12, 2004
7:26 pm
757
Dear All: We are trying to install NMRPipe on a linux box (Dell OptiPlex 170L with Redhat Linux 9.1). The "Install.com" ran fine. However, we got the...
Pei Zhou
masuying
Offline Send Email
Oct 13, 2004
7:56 pm
758
Dear all: Sorry to send the previous message under the wrong header. We are trying to install NMRPipe on a linux box (Dell OptiPlex 170L with Redhat Linux...
Pei Zhou
masuying
Offline Send Email
Oct 13, 2004
7:57 pm
759
This is from the installation instructions ... XView Notifier Errors using nmrDraw In some cases, "nmrDraw" may display "XView Notifier Error" or similar ...
Frank Delaglio
bigfdelaglio
Offline Send Email
Oct 13, 2004
9:23 pm
760
Hi, Frank: Thanks a lot! It worked. The missing menu is caused by a separate issue with the video card, which apparently displays a different memory size...
Pei Zhou
masuying
Offline Send Email
Oct 14, 2004
3:34 pm
761
We have a nmrDraw problem which has occured only on SGI installations. Some installations have a bug in which attempts to make keyboard entries (for instance,...
Scott Kennedy
scott_kennedyur
Offline Send Email
Oct 14, 2004
3:35 pm
762
Hi, pipers, I tried to use spscan to convert a 4D nmrpipe file to xeasy file, but failed. What I did is: showhdr -verb test%02d%03d.DAT > test.header and I...
lljiang001
Offline Send Email
Oct 14, 2004
3:41 pm
763
Ahhh yes. This is the mysterious XView "numlock" problem, I think, not a problem of permissions. Turn the "Numlock" mode of the numeric keypad "off" ... -f...
Frank Delaglio
bigfdelaglio
Offline Send Email
Oct 14, 2004
3:49 pm
764
I have the same problem- I noticed if nmrDraw is open on my SGI, and I use the number pad keys, nmrDraw freezes- but if I use the numbers on the regular type...
Meredith Newby Lambert
mnlamber
Offline Send Email
Oct 14, 2004
5:58 pm
765
Nevermind- I just saw Frank's message- Thanks!! :) --On Thursday, October 14, 2004 12:50 PM -0400 Meredith Newby Lambert ... -- Meredith Newby Lambert, Ph....
Meredith Newby Lambert
mnlamber
Offline Send Email
Oct 14, 2004
6:10 pm
766
Well, I had a feeling this was going to be easy -- but not THAT easy. Thanks Frank, --scott kennedy...
Scott Kennedy
scott_kennedyur
Offline Send Email
Oct 14, 2004
6:27 pm
767
Hi all, I've been trying to process an HCCH-TOCSY spectrum which utilizes the hcchdigp3d pulseprogram under XwinNMR 3.5 on Bruker Avance machines. Processing...
Chung-ke Chang
chungke@...
Send Email
Oct 18, 2004
2:11 pm
768
Hi, You should use "FT -alt" for the dimension acquired by States-TPPI. however, it is most safe and convinient using always "FT -auto" for all dimension. For...

solwind1024
Offline Send Email
Oct 18, 2004
4:24 pm
769
Hello nmrPipe users, I am trying to use ACME to determine 1H-1H coupling constants from a DQF-COSY. The software is designed for use with a "standard" (i.e. ...
Michelle L. Gill
michellelgill
Offline Send Email
Oct 21, 2004
9:14 pm
770
Hmmm. Probably a little dangerous. But ... Assuming that times are set up such that the system is fully-relaxed, so that all cross-peak amplitudes are the...
Frank Delaglio
bigfdelaglio
Offline Send Email
Oct 22, 2004
1:54 pm
771
Hello Newsgroup, I would like to draw your attention to an issue in NMRPipe and the way chemical shifts are calculated within the software. 1. Chemical shifts...
Roehrl, Michael H
michael_roehrl
Offline Send Email
Oct 22, 2004
4:50 pm
772
Hello, Although the transmitter frequency is used instead of the reference frequency, in practice this introduces a negligible error for nuclei with relatively...
David Bryce
davidlbryce
Offline Send Email
Oct 22, 2004
6:32 pm
773
Hello, When I use conversion tool, it shows 'always' wrong Center Position. As for Bruker, it use (for example, O1/SFO1) for Center Position, but real position...
Min-Kyu Cho
mich@...
Send Email
Oct 22, 2004
8:54 pm
774
Hi all, Is there a way to back convert NMRView '.nv' file to nmrPipe format? I am looking at some old processed data for which original data acquisitions are ...
Mandar Naik
mantrinaik
Offline Send Email
Oct 23, 2004
1:39 pm
775
Here are my two cents to calculate the referenceing for Bruker data: Attached please find three scripts for unix system, the main one "nref" takes an input...
Yufeng
crystalatom
Offline Send Email
Oct 25, 2004
5:34 pm
776
Dear Pipers, Could anybody give me examples about the delays used, with success, for the recording of a COSY for ACME? Is 3*T1 OK? Thanks in advance, Antonio....
adaranas
Offline Send Email
Oct 26, 2004
5:01 pm
777
Thanks Michael for your posting, and reminding us of the importance to use IUPAC referencing to share our data in a successful way. Being oblivious to...
Frans Mulder
frans.mulder@...
Send Email
Oct 27, 2004
10:54 am
778
ah yes, another little thing about referencing. It matters that the conversion values for the indirect dimensions are as accurate as possible. In our lab we...
Frans Mulder
frans.mulder@...
Send Email
Oct 27, 2004
2:37 pm
779
I am having difficulty with the peak labeling in the pipe version for MAC OS. Everytime I label a peak and move away from it the label gets distorted, moved,...
Dave Vuletich
chem007da
Offline Send Email
Oct 28, 2004
9:23 pm
780
hi Dave, don't know if it has been signalled before, but I experience - what looks to be - the same problem under Linux. Maybe nothing to do with nmrPipe ...?...
Frans Mulder
frans.mulder@...
Send Email
Oct 29, 2004
1:50 pm
781
hi, all Why do I get the error "file ./test.ft2 is not found" when I clicked the File option on the NMRDraw interface. If you have any idea about that, please...
vivienne
vivi721cn
Offline Send Email
Nov 2, 2004
3:03 am
782
Hi vivienne, you are clicking with left mouse button and there is no test.ft2 file under the directory you invoke nmrDraw. Try right button. ... = = = = = = =...