A couple of "gotchas" we windows users have to watch
using HyperTerminal is making sure the file is being
sent one line at a time, with at least a 100
millisecond pause between each and also make sure a CR
(carriage return) is sent at the end of each line.
The bootloader should return a . (period) at the end
of each line of HEX showing that it was received ok.
If you don't get the period, then the bootloader did
not get it.
Give that a try.
Jason KE4NYV
www.ke4nyv.com
RPC Electronics
www.rpc-electronics.com
--- "James R. Gorr" <n3toy@...> wrote:
>
> Anyone using minicom on Linux to load code to their
> PicPac? I am
> having trouble, the code does not load, it seems as
> if it did, but the
> old code is still in there after I press the reset
> button.
>
> Jamie
>
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>