184
Hi, I've just got qBase and i'm trynig to start using it. I've imported my first runs, which are standard curves to test the efficiency of my primers. When I...
I_Sudbery
Offline Send Email
Sep 5, 2006
9:55 am
185
I am getting my first experience with relative quantification. My ABI system is just offering a relative quantification software but it only works when...
martina.maria
Offline Send Email
Sep 8, 2006
5:57 am
186
Dear Martina How much samples do you have and how many groups? Jo...
jvdesomp
Offline Send Email
Sep 8, 2006
7:30 am
187
... Dear Jo at first: thanks a lot for your quick reply! I just want to tell you something about my samples(wheat samples from the field infected with the...
martina.maria
Offline Send Email
Sep 8, 2006
9:27 am
188
Dear Martina, qBase can be downloaded from http://medgen.ugent/qbase We experienced some mailserver issues, but these are solved now. Do not hesitate to get...
jvdesomp@...
jvdesomp
Offline Send Email
Sep 11, 2006
3:43 pm
189
hi there I am trying to use qBASE but 've got some problems! I downloaded succesfully the zip and started to use it but only few options are available when I...
aperesbota
Offline Send Email
Sep 28, 2006
9:23 am
190
Dear Adrian You probably mean that only a few of the items in the work flow are available. That is perfectly normal. Some require manual interaction, and can...
jvdesomp@...
jvdesomp
Offline Send Email
Sep 28, 2006
10:37 am
191
Hi Jo I am doing expression profile and when I am making my standard curve I am using 1x, 1/2, 1/4, 1/8, 1/16 dilution series since my cDNA amount is limiting....
aperesbota
Offline Send Email
Oct 2, 2006
2:07 pm
192
Hi, I have been running real time reactions on ABI-7300. For one particular sample I had 2 replicates and ran both the replicates in duplicates. But both the...
anshulawasthi
Offline Send Email
Oct 4, 2006
3:53 pm
193
Hi All, Just wondering is there a difference between the way GeNorm caluclates M value in comparison to Qbase. When I calculate with GeNorm I get M values of...
stephen_b00
Offline Send Email
Oct 6, 2006
3:45 pm
194
Can anyone give a definition of the relative quantities and the units used on the single gene histogram on the y axis? Greetings, Adrian...
aperesbota
Offline Send Email
Oct 11, 2006
7:17 pm
195
Dear Stephen Both qBase and geNorm use the same formula to calculate the M value. You do realize that the input is different for geNorm (should be relative ...
jvdesomp
Offline Send Email
Oct 12, 2006
9:54 pm
196
please note that we are talking about relative quantification, so the units are arbitrary units or 'fold change compared to the calibrator sample', or if you...
jvdesomp
Offline Send Email
Oct 12, 2006
9:55 pm
197
Dear Jo, Yes, my input for geNorm was the relative quantities, I divided the lowest CT value by every other sample. I have also double checked that its the...
stephen_b00
Offline Send Email
Oct 13, 2006
1:45 pm
198
Dear Stephen I'm afraid your calculations are not correct. You are not supposed to divide Ct values. Please take a look at the example calculation file on the...
jvdesomp@...
jvdesomp
Offline Send Email
Oct 13, 2006
3:11 pm
199
Dear Jo, Thanks for your help, for some reason I was using the ratios of lowest CT to other sample CT instead of relative quantities. Cheers, Stephen ... to ...
stephen_b00
Offline Send Email
Oct 22, 2006
4:11 pm
200
Hi, Just a quick question for the group. What are the main differences between version 1.3.3 and 1.3.4? I'm particularly interested in the computation...
fasdadga
Offline Send Email
Oct 31, 2006
12:16 am
201
The version history of qBase can now be found in the files section....
hellemans_jan
Offline Send Email
Oct 31, 2006
8:06 am
203
Am very impressed with qBase analysis of data file examples, but have had no success trying to format data from an Mx4000.From the manual it is clear that...
LJoseph98
Offline Send Email
Nov 12, 2006
9:37 am
204
Hi! I've been trying to use qBase for the last couple weeks. After getting all my input files correctly formatted and figuring out how to use the program I am...
federico_maria
Offline Send Email
Dec 2, 2006
6:40 pm
205
qBase is a relative quantification program employing universally applicable and advanced quantification models. Rescaling is performed on a gene per gene...
jvdesomp
Offline Send Email
Dec 3, 2006
8:43 pm
206
Hi! I saw your webpage and thought that qBase may provide tools that I need. I have a set of customized (sort of) qPCR data, which essentially is the...
daisuke_hattori
Offline Send Email
Dec 9, 2006
8:03 pm
207
Any table of Ct values that can be converted to any of the supported import types (see descriptions at the end of the manual) can be used by qBase after...
hellemans_jan
Offline Send Email
Dec 11, 2006
7:33 am
208
Hi Jan, Thank you for the prompt reply! Actually my data consist of the raw intensity with cycle numbers and need to calculate Ct values for each condition....
Daisuke Hattori
daisuke_hattori
Offline Send Email
Dec 12, 2006
7:17 am
209
We released a new version of qBase (minor bug fixes), along with a step-by-step tutorial detailing the different steps in the workflow (this is different than...
Jo Vandesompele
jvdesomp
Offline Send Email
Dec 19, 2006
2:51 pm
210
"qBase relative quantification framework and software for management and automated analysis of real-time quantitative PCR data" by Hellemans et al. is...
Jo Vandesompele
jvdesomp
Offline Send Email
Feb 9, 2007
2:24 pm
211
Dear Jo I am begining a fairly large qPCR study, but I am concerned that we may not be able to be able to analyse or data to it's full potential if we get the...
norniron950
Offline Send Email
Feb 11, 2007
9:19 am
212
... Of course! The sample maximization approach is only proposed to reduced inter-run variation when comparing samples. You are still able to compare genes...
jvdesomp
Offline Send Email
Feb 12, 2007
10:44 am
213
Thank you for your reply Jo You mention the use of IRCs in your reply. Can you clarify some points regarding IRCs for me please. In the qBase tutorial, the...
norniron950
Offline Send Email
Feb 12, 2007
7:57 pm
214
... Indeed, because all samples fit on the same plate. ... Correct. ... There is no run-to-run variatio, because all samples are tested in the same plate....
jvdesomp
Offline Send Email
Feb 12, 2007
8:39 pm