Dear Jo and Jan, My name is Davina and I have a problem with the relative quantification of my experiment. It consist of 7 96-well plates with on each plate 1 ...
davinatondeleir
Offline Send Email
May 7, 2007
6:31 am
247
Dear colleagues, I am starting to analyze my real-time data with qBase. It looks great, but apparently I have a problem with IRCs. I do not have samples spread...
annafra07
Offline Send Email
May 9, 2007
12:50 pm
248
Anna, qBase can not deal with technical replicates spread across plates very well. It will consider this as an experiment too large to fit into one plate,...
hellemans_jan
Offline Send Email
May 10, 2007
7:34 am
249
Davina, Your setup with just one plate per gene does not resuire inter-run calibration. What is the purpose of your callibrators? qBase allows you to compare...
hellemans_jan
Offline Send Email
May 10, 2007
8:54 am
250
The qBase Browser can not deal with 10 or more experiments in a single project. This problem can be circumvented by putting the tenth (and following)...
hellemans_jan
Offline Send Email
May 10, 2007
1:43 pm
251
The main difference between v1.2 and v1.3 of qBase is the switch from inter-run calibration based on Ct values to inter-run calibration based on normalized...
hellemans_jan
Offline Send Email
May 11, 2007
6:25 am
252
We run our qPCR studies on an ABI 7500. When using the ABI software for relative expression studies, the individual plates have to be imported into a relative...
norniron950
Offline Send Email
May 23, 2007
2:03 pm
253
When I want to start qBase , i f found some difficulties. After left clicking on the start qBase the MVB shows a message run-time error '1004' and said that...
sokatile
Offline Send Email
May 28, 2007
4:36 pm
254
You will have to unzip or extract the qBase.zip file. Apparently, you are working in the zip file after double clicking and opening it. Good luck. Jo...
jvdesomp
Offline Send Email
May 28, 2007
9:17 pm
255
Hi Have exactly the same runs repeated several times i.e. technical replicates in different runs though some are from different cDNA synthesis of the same RNA...
gossner50
Offline Send Email
May 31, 2007
10:09 am
256
Hi I have ranked my genes with geNORM but when I analyse with qBASE the same set of data the M values and the evaluation of the reference genes is totally...
aperesbota
Offline Send Email
May 31, 2007
9:23 pm
257
Hi I have a problem to import run data to my experiment. Every times I try, a message : an error occurred because one of the column headers is not correct. My...
sokatile
Offline Send Email
Jun 2, 2007
8:04 am
258
Convert your Excel table to the simple qBase format (see manual how this looks like). Jo...
jvdesomp
Offline Send Email
Jun 2, 2007
4:04 pm
259
This should not be the case. Please send your qBase export file and geNorm input file so we can have a look (qbase @ medgen dot ugent dot be). Jo...
jvdesomp
Offline Send Email
Jun 2, 2007
4:07 pm
260
Hi I still have trouble to import my excel file for analysis. the same message (an error occurred because one of the column header is not correct. I tried to...
sokatile
Offline Send Email
Jun 3, 2007
10:16 pm
261
Make a new table! Your qBase file should be EXACTLY as described in the manual (including the header names). Jo...
jvdesomp
Offline Send Email
Jun 4, 2007
6:29 am
262
The importer for ABI relative quantification is designed for single runs. Therefore data from a study with multiple plates will probably result in errors. The...
hellemans_jan
Offline Send Email
Jun 4, 2007
7:34 am
263
Hi reading my first question again I realise that what I mean to say is that I have repeated identical runs in terms of samples (though some are from separate...
gossner50
Offline Send Email
Jun 4, 2007
9:46 am
264
In principle inter-run calibration can be performed on Ct values or on normalized relative quantities. qBase performs IRC on NRQ's meaning that fresh cDNA...
hellemans_jan
Offline Send Email
Jun 4, 2007
10:18 am
265
G'day Jan, Thank you for the program. I have several problems. [1] I can import may data files into qBase but in the run editor view mode I can only see...
lizmattkids
Offline Send Email
Jun 5, 2007
6:03 am
266
Hello I am a new user of qbase. When I try to initialize experiment one in the tutorial, qbase crashes. I am running excel 9.0 on windows xp. Any help is...
kwasiconnor
Offline Send Email
Jun 18, 2007
6:02 pm
267
Hi. I tried to get familiar with the qbase software but I still have some problem. I have always a missing column (F2) for three run and also see 13 is always...
sokatile
Offline Send Email
Jun 18, 2007
9:38 pm
268 kwasiconnor
Offline Send Email
Jun 22, 2007
7:54 pm
269
Hey, I am a new user of qBase. Have had good succes with doing the tutorial and find qBase a very usefull tool for my work, thank you very much for that. ...
Helle Christophersen
hellemartha
Offline Send Email
Jun 25, 2007
9:13 am
270
Hi, I am currently designing a study with 3 genes (2 HKG, 1 gene of interest), and many samples and I want to use relative quantitation. The total number of...
matthewarno
Offline Send Email
Jun 26, 2007
2:33 pm
271
Hi When adding experiment 10 to a project the experiment is added but also adds two runs in the run box as #N/A and get error message Run time error 13 type...
gossner50
Offline Send Email
Jun 26, 2007
2:33 pm
272
You don't need inter-run calibrators, because both samples of the pair are tested on the same plate, and you compare only ratios (pre/post) across plates. The...
jvdesomp
Offline Send Email
Jun 27, 2007
7:48 am
273
qBase can not handle projects with more than 9 experiments properly (see item 250 in this forum). The workaround is to create an additional project and to put...
hellemans_jan
Offline Send Email
Jun 28, 2007
6:32 am
274
When analyzing NTC samples, normalization does not make sense. As a consequence normalized relative quantities for no template controls can end up everywhere,...
hellemans_jan
Offline Send Email
Jul 3, 2007
8:05 am
275
Having just downloaded the software I receive the following message - "run time error 438": object doesn't support this property or method - when clicking...
hecticbanzel
Offline Send Email
Jul 19, 2007
10:28 am