mfawzy79 wrote:
> actually, I'm already using DC 10.54 and i'm still having the problem
>
>
There is a bug in the ASIX chip that will cause it to not negotiate
correctly with some hubs/switches. The fix was to use a very long reset
to the chip, something like 3 seconds. It would work on a power-up but
not on later resets.
The bug was fixed in the Softools port of the stack. AFAIK, ZW never
implemented the fix. I also notice on the newer modules the no longer
feed a pin to the ASIX chip to use as a reset. So, your only option may
be to get a different hub/switch.
--
------------------------------------------
| Scott G. Henion| shenion@... |
| Consultant | Stone Mountain, GA |
| SHDesigns http://www.shdesigns.org |
------------------------------------------